Comparison of Intelligent Algorithms with FACTS Devices for Minimization of Total Power Losses

Author(s):  
Shohreh Monshizadeh ◽  
Gunne John Hegglid ◽  
Svein Thore Hagen

This report largely focused on the influence on the delivery system of the Renewable Distributed Generations (RDGs). DG's intercourse showed that the suggested the traditional method of radial distribution into a multiple DG scheme. The main contribution of this study is to reduce total power losses and increase the distribution system's power quality using RDGs. The Loss sensitivity factor (LSF) is used to find the RDGs. A heuristic search novel The Modified Bat Algorithm (MBA) is used to define the amount of the RDGs. MBA is largely focused on microbats' higher elastic modulus. The proposed MBA is measured on standard bus test systems IEEE 33 and 69.


Author(s):  
Michael Westman ◽  
Ove Isaksson

This paper is concerned with forest logging machinery. A great deal of final felling in cut-to-length method done by harvester, which fells, delimbs and cuts the trees to pre-selected lengths. Two important criteria of a harvester head are that it has to be energy efficient and it has to be as fast as possible. To minimize losses in hydraulic systems the main demand is to reduce pressure losses in high power valves and outer components as much as possible. Each orifice in the flow path results in power losses. This work is an experimental study on power losses and acceleration of hydraulic motor in a system with long hoses. Main hydraulic components included are hydraulic pump, cartridge valve, pipe line and hydraulic motor. The results show that pre-activating the pump improves the system speed. To reduce losses, optimization of valve block, cartridge valve orifices are needed. Accumulators are favourable if combined with high stand-by pressure.


2021 ◽  
Vol 143 (11) ◽  
Author(s):  
A. Dindar ◽  
K. Chaudhury ◽  
I. Hong ◽  
A. Kahraman ◽  
C. Wink

Abstract In this study, an experimental methodology is presented to separate various components of the power loss of a gearbox. The methodology relies on two separate measurements. One is designed to measure total power loss of a gearbox housing a single spur gear pair under both loaded and unloaded conditions such that load-independent (spin) and load-dependent (mechanical) components can be separated. With the assumption that gear pair and rolling element bearings constitute the bulk of the gearbox power loss, a second measurement system designed to quantify rolling element bearing losses is proposed. With this setup, spin and mechanical power losses of rolling element bearings used in the gearbox experiments are measured. Combining the sets of gearbox and bearing data, power loss components attributable to the gear pair and rolling element bearings are quantified as a function of speed and torque. The results indicate that all gear and bearing related components are significant and a methodology such as the one proposed in this study is warranted.


2019 ◽  
Vol 6 (2) ◽  
pp. 7
Author(s):  
I. K. A. Wijaya ◽  
R. S. Hartati ◽  
I W. Sukerayasa

Saba feeder is a feeder who supplies 78 distribution transformers with feeder length 38,959 kms, through this Saba feeder electrical energy is channeled radially to each distribution substation. In 2017 the voltage shrinkage at Saba feeder was 9.88% (18,024 kV) while the total power loss was 445.5 kW. In this study an attempt was made to overcome the voltage losses and power losses using the method of optimizing bank capacitors with genetic algorithms and network reconfiguration. The best solution obtained from this study will be selected for repair of voltage losses and power losses in Saba feeders. The results showed that by optimizing bank capacitors using genetic algorithms, the placement of capacitor banks was placed on bus 23 (the channel leading to the BB0024 transformer) and successfully reduced the power loss to 331.7 kW. The network reconfiguration succeeded in fixing the voltage on the Saba feeder with a voltage drop of 4.75% and a total power loss of 182.7 kW. With the combined method, reconfiguration and optimization of bank capacitors with genetic algorithms were obtained on bus 27 (channel to transformer BB0047) and managed to reduce power losses to 143 kW.


2015 ◽  
Vol 14 (2) ◽  
pp. 27
Author(s):  
I Made Gusmara Nusaman ◽  
I Wayan Sukerayasa ◽  
Rukmi Sari Hartati

The distributed generation technology or in this case abbreviated DG is a kind of power plants with small scale which prioritizes the utilization of renewable energy resources such as wind, water, solar, geothermal, ocean waves (Wave Energy), ocean currents (Ocean Current Energy), biomass, and biogass to produce the electrical energy with range of power generation between 1 kW-10 MW. One of the DG in Bali and still in operation is the garbage power plant which located in Suwung, South Denpasar. An analysis has been done using load flow analysis and reliability assessment to determine the effect of DG interconnection against the power losses and the level of reliability on the Serangan feeder. Based on the research that has been done, DG intercon-nection on the Serangan feeder decrease the power losses and increase the reliability and it can visible from the acquisition of SAIFI and SAIDI index which decreased. The best location of DG interconnection to get low of the power losses and the high level of reliability is at 97% from the total length of the feeder. At that location the power losses is decrease as big as 4.5 kW or 11.25% of the total power lossess without the DG interconnection and decrease of the SAIFI and SAIDI index respectively to 0.1 failure/customers/year and 1.4150 hour/ customer/year


Inventions ◽  
2020 ◽  
Vol 5 (3) ◽  
pp. 37 ◽  
Author(s):  
Omar H. Abdalla ◽  
Hady H. Fayek ◽  
A. M. Abdel Ghany

This paper presents secondary voltage control by extracting reactive power from renewable power technologies to control load buses voltage in a power system at different operating conditions. The study is performed on a 100% renewable 14-bus system. Active and reactive powers controls are considered based on grid codes of countries with high penetration levels of renewable energy technologies. A pilot bus is selected in order to implement the secondary voltage control. The selection is based on short-circuit calculation and sensitivity analysis. An optimal Proportional Integral Derivative (PID) voltage controller is designed using genetic algorithm. A comparison between system with and without secondary voltage control is presented in terms of voltage profile and total power losses. The optimal voltage magnitudes at busbars are calculated to achieve minimum power losses using optimal power flow. The optimal placement of Phasor Measurement Units (PMUs) is performed in order to measure the voltage magnitude of buses with minimum cost. Optimization and simulation processes are performed using DIgSILENT and MATLAB software applications.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2283
Author(s):  
Atif Naveed Khan ◽  
Kashif Imran ◽  
Muhammad Nadeem ◽  
Anamitra Pal ◽  
Abraiz Khattak ◽  
...  

Flexible AC Transmission Systems (FACTS) are essential devices used for the efficient performance of modern power systems and many developing countries lack these devices. Due to the non-existence of these advanced technologies, the national grid remains weak and vulnerable to power stability issues that can jeopardize system stability. This study proposes novel research to solve issues of an evolving national grid through the installation of FACTS devices. FACTS devices play a crucial role in minimizing active power losses while managing reactive power flows to keep the voltages within their respective limits. Due to the high costs of FACTS, optimization must be done to discover optimal locations as well as ratings of these devices. However, due to the nonlinearity, it is a challenging task to find the optimal locations and appropriate sizes of these devices. Shunt VARs Compensators (SVCs) and Thyristor-Controlled Series Compensators (TCSCs) are the two FACTS devices considered for the study. Optimal locations for SVCs and TCSCs are determined by Voltage Collapse Proximity Index (VCPI) and Line Stability Index (Lmn), respectively. Particle Swarm Optimization (PSO) is employed to find the ideal rating for FACTS devices to minimize the system operating cost (cost due to active power loss and capital cost of FACTS devices). This technique is applied to IEEE (14 and 30) bus systems. Moreover, reliable operation of the electricity grid through the placement of FACTS for developing countries has also been analysed; Pakistan being a developing country has been selected as a case study. The planning problem has been solved for the present as well as for the forecasted power system. Consequently, in the current national network, 6.21% and 6.71% reduction in active and reactive power losses have been observed, respectively. Moreover, voltage profiles have been improved significantly. A detailed financial analysis covering the calculation of Operation Cost (OC) of the national grid before and after the placement of FACTS devices is carried out.


Author(s):  
Abdulhamid Musa ◽  
Tengku Juhana Tengku Hashim

This paper presents a Genetic Algorithm (GA) for optimal location and sizing of multiple distributed generation (DG) for loss minimization. The study is implemented on a 33-bus radial distribution system to optimally allocate different numbers of DGs through the minimization of total active power losses and voltage deviation at power constraints of 0 – 2 MW and 0 – 3 MW respectively. The study proposed a PQ model of DG and Direct Load Flow (DLF) technique that uses Bus Incidence to Branch current (BIBC) and Branch Current to Bus Voltage (BCBV) matrices. The result obtained a minimum base case voltage level of 0.9898 p.u at bus 18 with variations of voltage improvements at other buses after single and multiple DG allocations in the system. Besides, the total power loss before DG allocation is observed as 0.2243 MW, and total power loss after DG allocation was determined based on the power constraints. Various optimal locations were seen depending on the power limits of different DG sizes. The results have shown that the impact of optimal allocation and sizing of three DG is more advantageous concerning voltage improvement, reduction of the voltage deviation and also total power loss in the distribution system. The results obtained in the 0 – 2 MW power limit is consistent to the 0 – 3 MW power limits regarding the influence of allocating DG to the network and minimization of total power losses.