2021 ◽  
Vol 1 (1) ◽  
pp. 50-59
Author(s):  
Yousef Zandi ◽  
Afram Keivani

In the analysis of rectangular reinforced liquid storage tanks, a method assuming linear-elastic behavior for material can be used, i.e., the strip method, the moment coefficient method, the finite element method, etc. In the analysis of these types of tanks, tank walls can be considered as slabs. In this study, tank walls were analyzed as slabs subjected to hydrostatic loading; in the analysis, the yield line theory is used because it is more suitable for the linear inelastic behavior of reinforced concrete slabs than the ones based on the linear elastic theory. An iterative algorithm based on yield line theory is presented for the design of isotropically reinforced recrangular concrete slabs supported along all four edges. A computer program is coded which predicts the location of yield lines for the slabs depending upon certain parameters. As a result of this prediction, the manual design of such slabs can be significantly simplified by the use of the coefficient obtained by using the program. It was shown that the analytical computation of the ultimate moment per unit length requires the solution of a highly nonlinear system of equations. This difficulty was overcome by utilizing an iterative technique within the computer program. It also gives the value of the ultimate moment per unit length of the yield line.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4622
Author(s):  
Kevin Paolo V. Robles ◽  
Jurng-Jae Yee ◽  
Seong-Hoon Kee

The main objectives of this study are to evaluate the effect of geometrical constraints of plain concrete and reinforced concrete slabs on the Wenner four-point concrete electrical resistivity (ER) test through numerical and experimental investigation and to propose measurement recommendations for laboratory and field specimens. First, a series of numerical simulations was performed using a 3D finite element model to investigate the effects of geometrical constraints (the dimension of concrete slabs, the electrode spacing and configuration, and the distance of the electrode to the edges of concrete slabs) on ER measurements of concrete. Next, a reinforced concrete slab specimen (1500 mm (width) by 1500 mm (length) by 300 mm (thickness)) was used for experimental investigation and validation of the numerical simulation results. Based on the analytical and experimental results, it is concluded that measured ER values of regularly shaped concrete elements are strongly dependent on the distance-to-spacing ratio of ER probes (i.e., distance of the electrode in ER probes to the edges and/or the bottom of the concrete slabs normalized by the electrode spacing). For the plain concrete, it is inferred that the thickness of the concrete member should be at least three times the electrode spacing. In addition, the distance should be more than twice the electrode spacing to make the edge effect almost negligible. It is observed that the findings from the plain concrete are also valid for the reinforced concrete. However, for the reinforced concrete, the ER values are also affected by the presence of reinforcing steel and saturation of concrete, which could cause disruptions in ER measurements


2020 ◽  
pp. 136943322097814
Author(s):  
Xing-lang Fan ◽  
Sheng-jie Gu ◽  
Xi Wu ◽  
Jia-fei Jiang

Owing to their high strength-to-weight ratio, superior corrosion resistance, and convenience in manufacture, fiber-reinforced polymer (FRP) bars can be used as a good alternative to steel bars to solve the durability issue in reinforced concrete (RC) structures, especially for seawater sea-sand concrete. In this paper, a theoretical model for predicting the punching shear strength of FRP-RC slabs is developed. In this model, the punching shear strength is determined by the intersection of capacity and demanding curve of FRP-RC slabs. The capacity curve is employed based on critical shear crack theory, while the demand curve is derived with the help of a simplified tri-linear moment-curvature relationship. After the validity of the proposed model is verified with experimental data collected from the literature, the effects of concrete strength, loading area, FRP reinforcement ratio, and effective depth of concrete slabs are evaluated quantitatively.


2021 ◽  
Vol 3 (6) ◽  
Author(s):  
Elena Marrocchino ◽  
Chiara Telloli ◽  
Alessandra Aprile ◽  
Domenico Capuani ◽  
Davide Malaguti ◽  
...  

Sign in / Sign up