Using Mutual Information for Exploring Optimal Light Source Placements

Author(s):  
Yuki Ohtaka ◽  
Shigeo Takahashi ◽  
Hsiang-Yun Wu ◽  
Naoya Ohta
Author(s):  
Michael T. Bucek ◽  
Howard J. Arnott

It is believed by the authors, with supporting experimental evidence, that as little as 0.5°, or less, knife clearance angle may be a critical factor in obtaining optimum quality ultrathin sections. The degree increments located on the knife holder provides the investigator with only a crude approximation of the angle at which the holder is set. With the increments displayed on the holder one cannot set the clearance angle precisely and reproducibly. The ability to routinely set this angle precisely and without difficulty would obviously be of great assistance to the operator. A device has been contrived to aid the investigator in precisely setting the clearance angle. This device is relatively simple and is easily constructed. It consists of a light source and an optically flat, front surfaced mirror with a minute black spot in the center. The mirror is affixed to the knife by placing it permanently on top of the knife holder.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


Author(s):  
Antara Dasgupta ◽  
Renaud Hostache ◽  
RAAJ Ramasankaran ◽  
Guy J.‐P Schumann ◽  
Stefania Grimaldi ◽  
...  

2003 ◽  
Vol 104 ◽  
pp. 557-561 ◽  
Author(s):  
M. R. Howells ◽  
H. Chapman ◽  
S. Hau-Riege ◽  
H. He ◽  
S. Marchesini ◽  
...  

1997 ◽  
Vol 36 (04/05) ◽  
pp. 257-260 ◽  
Author(s):  
H. Saitoh ◽  
T. Yokoshima ◽  
H. Kishida ◽  
H. Hayakawa ◽  
R. J. Cohen ◽  
...  

Abstract:The frequency of ventricular premature beats (VPBs) has been related to the risk of mortality. However, little is known about the temporal pattern of occurrence of VPBs and its relationship to autonomic activity. Hence, we applied a general correlation measure, mutual information, to quantify how VPBs are generated over time. We also used mutual information to determine the correlation between VPB production and heart rate in order to evaluate effects of autonomic activity on VPB production. We examined twenty subjects with more than 3000 VPBs/day and simulated ran-( dom time series of VPB occurrence. We found that mutual information values could be used to characterize quantitatively the temporal patterns of VPB generation. Our data suggest that VPB production is not random and VPBs generated with a higher value of mutual information may be more greatly affected by autonomic activity.


1978 ◽  
Vol 17 (01) ◽  
pp. 36-40 ◽  
Author(s):  
J.-P. Durbec ◽  
Jaqueline Cornée ◽  
P. Berthezene

The practice of systematic examinations in hospitals and the increasing development of automatic data processing permits the storing of a great deal of information about a large number of patients belonging to different diagnosis groups.To predict or to characterize these diagnosis groups some descriptors are particularly useful, others carry no information. Data screening based on the properties of mutual information and on the log cross products ratios in contingency tables is developed. The most useful descriptors are selected. For each one the characterized groups are specified.This approach has been performed on a set of binary (presence—absence) radiological variables. Four diagnoses groups are concerned: cancer of pancreas, chronic calcifying pancreatitis, non-calcifying pancreatitis and probable pancreatitis. Only twenty of the three hundred and forty initial radiological variables are selected. The presence of each corresponding sign is associated with one or more diagnosis groups.


2019 ◽  
pp. 101-107
Author(s):  
Sergei A. Stakharny

This article is a review of the new light source – organic LEDs having prospects of application in general and special lighting systems. The article describes physical principles of operation of organic LEDs, their advantages and principal differences from conventional non-organic LEDs and other light sources. Also the article devoted to contemporary achievements and prospects of development of this field in the spheres of both general and museum lighting as well as other spheres where properties of organic LEDs as high-quality light sources may be extremely useful.


Sign in / Sign up

Export Citation Format

Share Document