A new high voltage (350 kV) universal electron microscope and its applications

1960 ◽  
pp. 165-166 ◽  
Author(s):  
K. Kobayashi ◽  
E. Suito ◽  
S. Shimadzu
Author(s):  
J. S. Lally ◽  
R. Evans

One of the instrumental factors often limiting the resolution of the electron microscope is image defocussing due to changes in accelerating voltage or objective lens current. This factor is particularly important in high voltage electron microscopes both because of the higher voltages and lens currents required but also because of the inherently longer focal lengths, i.e. 6 mm in contrast to 1.5-2.2 mm for modern short focal length objectives.The usual practice in commercial electron microscopes is to design separately stabilized accelerating voltage and lens supplies. In this case chromatic aberration in the image is caused by the random and independent fluctuations of both the high voltage and objective lens current.


Author(s):  
J.L. Williams ◽  
K. Heathcote ◽  
E.J. Greer

High Voltage Electron Microscope already offers exciting experimental possibilities to Biologists and Materials Scientists because the increased specimen thickness allows direct observation of three dimensional structure and dynamic experiments on effectively bulk specimens. This microscope is designed to give maximum accessibility and space in the specimen region for the special stages which are required. At the same time it provides an ease of operation similar to a conventional instrument.


Author(s):  
J. Temple Black

Since its introduction by Fernandez-Moran, the diamond knife has gained wide spread usage as a common material for cutting of thin sections of biological and metallic materials into thin films for examination in the transmission electron microscope. With the development of high voltage E.M. and scanning transmission E.M., microtomy applications will become increasingly important in the preparation of specimens. For those who can afford it, the diamond knife will thus continue to be an important tool to accomplish this effort until a cheaper but equally strong and sharp tool is found to replace the diamond, glass not withstanding.In Figs. 1 thru 3, a first attempt was made to examine the edge of a used (β=45°) diamond knife by means of the scanning electron microscope. Because diamond is conductive, first examination was tried without any coating of the diamond. However, the contamination at the edge caused severe charging during imaging. Next, a thin layer of carbon was deposited but charging was still extensive at high magnification - high voltage settings. Finally, the knife was given a light coating of gold-palladium which eliminated the charging and allowed high magnification micrographs to be made with reasonable resolution.


Author(s):  
M. Nishigaki ◽  
S. Katagiri ◽  
H. Kimura ◽  
B. Tadano

The high voltage electron microscope has many advantageous features in comparison with the ordinary electron microscope. They are a higher penetrating efficiency of the electron, low chromatic aberration, high accuracy of the selected area diffraction and so on. Thus, the high voltage electron microscope becomes an indispensable instrument for the metallurgical, polymer and biological specimen studies. The application of the instrument involves today not only basic research but routine survey in the various fields. Particularly for the latter purpose, the performance, maintenance and reliability of the microscope should be same as those of commercial ones. The authors completed a 500 kV electron microscope in 1964 and a 1,000 kV one in 1966 taking these points into consideration. The construction of our 1,000 kV electron microscope is described below.


Author(s):  
Murray Vernon King ◽  
Donald F. Parsons

Effective application of the high-voltage electron microscope to a wide variety of biological studies has been restricted by the radiation sensitivity of biological systems. The problem of radiation damage has been recognized as a serious factor influencing the amount of information attainable from biological specimens in electron microscopy at conventional voltages around 100 kV. The problem proves to be even more severe at higher voltages around 1 MV. In this range, the problem is the relatively low sensitivity of the existing recording media, which entails inordinately long exposures that give rise to severe radiation damage. This low sensitivity arises from the small linear energy transfer for fast electrons. Few developable grains are created in the emulsion per electron, while most of the energy of the electrons is wasted in the film base.


Author(s):  
W. E. King

A side-entry type, helium-temperature specimen stage that has the capability of in-situ electrical-resistivity measurements has been designed and developed for use in the AEI-EM7 1200-kV electron microscope at Argonne National Laboratory. The electrical-resistivity measurements complement the high-voltage electron microscope (HVEM) to yield a unique opportunity to investigate defect production in metals by electron irradiation over a wide range of defect concentrations.A flow cryostat that uses helium gas as a coolant is employed to attain and maintain any specified temperature between 10 and 300 K. The helium gas coolant eliminates the vibrations that arise from boiling liquid helium and the temperature instabilities due to alternating heat-transfer mechanisms in the two-phase temperature regime (4.215 K). Figure 1 shows a schematic view of the liquid/gaseous helium transfer system. A liquid-gas mixture can be used for fast cooldown. The cold tip of the transfer tube is inserted coincident with the tilt axis of the specimen stage, and the end of the coolant flow tube is positioned without contact within the heat exchanger of the copper specimen block (Fig. 2).


Author(s):  
P. R. Okamoto ◽  
N.Q. Lam ◽  
R. L. Lyles

During irradiation of thin foils in a high voltage electron microscope (HVEM) defect gradients will be set up between the foil surfaces and interior. In alloys defect gradients provide additional driving forces for solute diffusion since any preferential binding and/or exchange between solute atoms and mobile defects will couple a net flux of solute atoms to the defect fluxes. Thus, during irradiation large nonequilibrium compositional gradients can be produced near the foil surfaces in initially homogeneous alloys. A system of coupled reaction-rate and diffusion equations describing the build up of mobile defects and solute redistribution in thin foils and in a semi-infinite medium under charged-particle irradiation has been formulated. Spatially uniform and nonuniform damage production rates have been used to model solute segregation under electron and ion irradiation conditions.An example calculation showing the time evolution of the solute concentration in a 2000 Å thick foil during electron irradiation is shown in Fig. 1.


Author(s):  
George Christov ◽  
Bolivar J. Lloyd

A new high intensity grid cap has been designed for the RCA-EMU-3 electron microscope. Various parameters of the new grid cap were investigated to determine its characteristics. The increase in illumination produced provides ease of focusing on the fluorescent screen at magnifications from 1500 to 50,000 times using an accelerating voltage of 50 KV.The EMU-3 type electron gun assembly consists of a V-shaped tungsten filament for a cathode with a thin metal threaded cathode shield and an anode with a central aperture to permit the beam to course the length of the column. The cathode shield is negatively biased at a potential of several hundred volts with respect to the filament. The electron beam is formed by electrons emitted from the tip of the filament which pass through an aperture of 0.1 inch diameter in the cap and then it is accelerated by the negative high voltage through a 0.625 inch diameter aperture in the anode which is at ground potential.


Author(s):  
K. Shiraishi ◽  
T. Katsuta ◽  
S. Ozasa ◽  
H. Todokoro

We have recently completed a newly designed 650KV electron microscope. An external view of this advanced instrument is shown in Figure 1. A symmetrical Cockcroft-Walton circuit has been adopted as the high voltage generator. The cathode is heated by high frequency power; a battery is not employed. The high voltage stability is better than 1 x 10-5/min.The sectional diagram of the column shown in Figure 2 is 420mm in diameter and 2750mm in height. The illuminating system consists of a double condenser lens and a magnetic alignment device. Dual deflector assemblies for dark and bright field images, selectable by push button, are built beneath the condenser lens. Two selectable stigmator power supplies are also provided for dark and bright field image operation.


Author(s):  
K. Tsuno ◽  
Y. Harada ◽  
T. Sato

Magnetic domains of ferromagnetic amorphous ribbon have been observed using Bitter powder method. However, the domains of amorphous ribbon are very complicated and the surface of ribbon is not flat, so that clear domain image has not been obtained. It has been desired to observe more clear image in order to analyze the domain structure of this zero magnetocrystalline anisotropy material. So, we tried to observe magnetic domains by means of a back-scattered electron mode of high voltage scanning electron microscope (HVSEM).HVSEM method has several advantages compared with the ordinary methods for observing domains: (1) high contrast (0.9, 1.5 and 5% at 50, 100 and 200 kV) (2) high penetration depth of electrons (0.2, 1.5 and 8 μm at 50, 100 and 200 kV). However, image resolution of previous HVSEM was quite low (maximum magnification was less than 100x), because the objective lens cannot be excited for avoiding the application of magnetic field on the specimen.