Oscillation Due to Vortex Shedding of Reinforced Concrete Chimneys of Rectangular Cross-Section

Author(s):  
T. A. Wyatt
2016 ◽  
Vol 9 (1) ◽  
pp. 1-21 ◽  
Author(s):  
D. B. FERREIRA ◽  
R. B. GOMES ◽  
A. L. CARVALHO ◽  
G. N. GUIMARÃES

This article presents the study of reinforced concrete columns strengthened using a partial jacket consisting of a 35mm self-compacting concrete layer added to its most compressed face and tested in combined compression and uniaxial bending until rupture. Wedge bolt connectors were used to increase bond at the interface between the two concrete layers of different ages. Seven 2000 mm long columns were tested. Two columns were cast monolithically and named PO (original column) e PR (reference column). The other five columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and other columns had a 155 mm by 250mm cross section after the strengthening procedure. Results show that the ultimate resistance of the strengthened columns was more than three times the ultimate resistance of the original column PO, indicating the effectiveness of the strengthening procedure. Detachment of the new concrete layer with concrete crushing and steel yielding occurred in the strengthened columns.


Author(s):  
Micha Premkumar Thomai ◽  
Lasoodawanki Kharsati ◽  
Nakandhrakumar Rama Samy ◽  
Seralathan Sivamani ◽  
Hariram Venkatesan

Abstract Vortex-induced vibration is one of the predominant fundamental concepts for forced oscillation which attracts considerable practical engineering application for energy conversion. In this work, an oscillation of a mast arising as a result of wind force is utilized for energy conversion. The paradigm for energy conversion from vortex-induced vibration in the mast is the bladeless wind turbine. It consists of a rigid mass known as a mast, fixed in the spring of stiffness (k) and allowed to oscillate along the direction of the flow. In this work, four different types of mast have been fabricated and tested. The first is uniform tapered hollow conical mast (MAST1), the cross-section of the second is uniform tapered plus symbol (MAST2), the third is uniform tapered inversed plus symbol (MAST3) and the fourth is uniform tapered simple rectangular cross-section (MAST4). All the masts were fabricated using fiber carbon. The experiments were conducted in a versatile small wind turbine testing facility of Hindustan Institute of Technology and Science, Chennai. This test facility contained an open jet wind tunnel with variable frequency drive and other measuring instruments. The vibration sensor was located in the mast where it experienced a large oscillation in a free stream. In this experiment, an increase in wind velocity led to a terrible change in the amplitude of vibration. A vigorous oscillation was experienced in this mast at this critical frequency, when the natural frequency of the mast was synchronized with the frequency of the vortex shedding and the frequency of the oscillation of the mast. The total force in this oscillation was a summation of the body force due to the mass of the mast and vorticity force that is mainly which was the result of the shedding of the vortices. In this work, extensive studies have been carried out for Reynolds number ranging from 2.5 × 105 to 5.0 × 105. The mast length to diameter ratio of 13 was exposed to various speeds of wind and response was measured. The occurrence of the maximum oscillation in a simple rectangular mast was seen where vortex shedding due to the bluff body was large for constant mass and spring stiffness. The frequency of the oscillation at maximum amplitude of the rectangular cross-section mast was equal to the natural frequency, due to vortices shedding at critical velocity. This demonstrated the appropriateness of the simple rectangular cross-section for harnessing the low rated wind energy and its suitability for renewable energy conversion in the small bladeless wind turbine.


2015 ◽  
Vol 8 (2) ◽  
pp. 88-99
Author(s):  
M. G. Marques ◽  
A. P. A. R. Liserre ◽  
R. B. Gomes ◽  
G. N. Guimarães

Strengthening of reinforced concrete columns by jacketing is one of the most common structural rehabilitation techniques in Brazil. For adequate performance, it is necessary, among others, to avoid detachment of the new concrete layer (strengthening material) from the old concrete substrate when the strengthened member is again in service conditions. This paper describes the test results of eight reinforced concrete rectangular columns subjected to combined compression and one-axis bending to evaluate the efficiency of using sleeve wedge bolts across the new concrete/old concrete interface to avoid detachment. The strengthening technique, in this case, consists of adding a layer of self-compacting concrete to one face of the column. Two columns tested were monolithic and named PO (original column) e PR (reference column). The other six columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and its results gave information about column behavior without the use of strengthening. Column PR had a 155mm by 250 mm rectangular cross section and its cross section dimensions matched the strengthened columns but it was cast monolithically. To improve bond conditions between the existing concrete and the new concrete, the concrete surface was roughened and the outermost aggregate was exposed using hydro jetting. Holes along the concrete surface were made to insert the wedge bolts responsible for increasing the bond between the two concrete surfaces. The difference among the six strengthened columns was the position and amount of bolts used. Results indicate that the position and amount of the bolts alters significantly the strength capacity of the columns, since premature rupture by concrete detachment was delayed.


Author(s):  
Maurício Castelo Branco de Noronha Campos ◽  
Paulo Marcelo Vieira Ribeiro ◽  
Romilde Almeida de Oliveira

abstract: This study addresses a numerical analysis of reinforced concrete columns in which the lengths are significantly larger than their widths with a rectangular cross section. Numerical simulations of 1,440 cases were performed, each case simulated with the single bar model, isolated bar model and mesh model, in addition, 3D model simulations were carried out. For the validation of 3D models and bar models, comparisons were made between the numerical simulation e experimental results of 24 reinforced concrete columns. Second order effects were analyzed on the vertical moment at the edge of the columns in which the lengths are significantly larger than the widths (localized second-order effects) and also the values of the horizontal moments along the cross sectional length in the mesh model. Influences of the main variables were observed influencing the behavior of the columns in which the lengths are significantly larger than their widths: the ratio between the cross sectional dimensions, the slenderness and the stresses (normal stress and bending moment around the axis of greatest inertia).


Author(s):  
V. P. Zhyrakhivskyi ◽  
М. G. Chekanovych ◽  
О. М. Chekanovych

The study presents a new structure for strengthening of one-span reinforced concrete beams in rectangular cross-section using external steel bars. The specific feature of the proposed strengthening is the unloading of the compressed upper zone of a beam with simultaneous compression of its lower stretched zone. The article considers some variants of making the strengthening structure with rigid and flexible reinforcement elements for faster tension of external bars, and the variant including only flexible elements. It provides a design scheme and method for such reinforced beams. The study provides experimental research data on the series of beams with different parameters of the strengthening structure in the form of «bending moment – deflection» and «bending moment - deformation of concrete» dependencies.


2013 ◽  
Vol 663 ◽  
pp. 159-163
Author(s):  
Hae Jun Yang ◽  
Hyun Do Yun

In this study, two reinforced concrete (RC) squat shear walls with height-to-length ratio of 0.55 and non-ductile reinforcement details are tested under reversed cyclic loading. Emphasis of the study is placed on the hysteretic behavior and cracking procedure of RC squat shear walls in accordance with the presence and absence of vertical seam on the wall panel. Two specimens had the same rectangular cross-section of 1,100 x 50mm, with wall panel heights of 600mm. To investigate the effect of vertical seams on the wall panel on the structural behavior of shear wall, one wall (CON-S) with three vertical seams with dimension of 260 x 40mm was made and the other (CON-N) was a solid wall without seams. The test results indicated that a squat shear wall with vertical seams exhibited more stable hysteretic behavior than a solid shear wall. Vertical seams on the wall panel improve the ductility and energy dissipation capacity but decrease the maximum strength of RC non-ductile squat shear wall.


2015 ◽  
Vol 6 (1) ◽  
pp. 49-58 ◽  
Author(s):  
Robert Kowalski ◽  
Michal Glowacki ◽  
Marian Abramowicz

The paper presents results of experimental research whose main topic was determination of stiffness reduction in bent reinforced concrete beams in two cases: when only tensioned or only compressed zone was exposed to high temperature. Twenty four reinforced concrete beams with rectangular cross-section were prepared for the experiment. Eight groups of beams were prepared in total: 2 with reinforcement ratio - 0.44 and 1.13% x 2 levels of load - 50 or 70% of destructive force ensuring the constant value of bending moment in the centre part of heated beams x 2 static schemes. Three beams were used in each group. Significant cross-section stiffness reduction was observed in beams where the tensile zone was heated. This was due to considerable elongation of the bars where the steel load elongation summed up with the free thermal strain. In beams where the compressed zone was heated the stiffness reduction was observed only after the time where the tensile zone heated cross-sections were already destroyed.