Evanescent-Wave Particle Visualization in Nano- and Microchannels

2016 ◽  
pp. 1139-1145
Author(s):  
Minami Yoda
2020 ◽  
Vol 12 ◽  
Author(s):  
Ritesh Kumar Singh ◽  
Adarsh Chandra Mishra ◽  
Pooja Lohia ◽  
D.K. Dwivedi

Background: Refractive index determination of biological tissues is a challenging issue. Many biological species also show vibrational signature in infrared domain. The chalcogenide-based glasses can be used to make the fiber optic evanescent wave sensors for detection of analyte. Objectives: The primary objective is to study the effect of various parameters on the sensitivity of chalcogenide glass-based evanescent wave sensor for biological tissue detection. Methods: An evanescent wave sensor has been proposed with collimated source illumination and uniform tapering. The chalcogenide materials are chosen such that the weakly guiding approximation could be followed. Complex refractive indices of liver tissue samples have been taken for the analysis of sensitivity via method of evanescent absorption coefficient. Equations for sensitivity have been solved analytically using MATLAB software. Results: The simplification of the formula for sensitivity leads to the inference that the sensitivity is a function of core radius, refractive indices of sample tissues and wavelength used. Moreover, since the refractive indices of the materials are also a function of temperature, therefore a change in temperature results into change in the profile of guiding mode. Hence the effect of temperature must also be observed. The initial simulation parameters are taken; core radius 100 µm, sensing length 4 cm and wavelength 1.0 µm. In the NIR region we have a better sensitivity of detection for all the tissues samples and the risk of photodamage of the biosamples is reduced to a good extent. It has been found that sensitivity decreases with wavelength and core radius whereas increases with temperature. It has also been shown that sensitivity is found to be better with collimated in comparison with diffused source. Conclusion: The comparative study results that one should operate at shorter NIR region of wavelength for higher sensitivity. The collimated source illumination should be preferred over diffused one for launching the light within the fiber to have high sensitivity. Further, length of sensing region should be larger but the fiber core radius should be smaller. The proposed biosensor is robust and can also be used many times if the probe (sensing region) is cleaned properly. Moreover, a small amount of analyte is enough for the detection. Thus, the proposed sensor is very useful for bio-medical applications with its high performance, accuracy and robustness.


Photonics ◽  
2021 ◽  
Vol 8 (3) ◽  
pp. 66
Author(s):  
Yuchen Wang ◽  
Hongsheng Li ◽  
Shu Hu ◽  
Heng Li ◽  
Chuanxiang Sheng

Using a fiber of that is 125 μm in diameter in rhodamine 6G ethanol solution, controllable multi- and single-whispering-gallery-mode (WGM) optofluidic lasers based on evanescent-wave-coupled gain are both available. With multi-mode WGM emission, lasing emission with almost pure TM (transverse magnetic) or almost TE (transverse electric) modes can be obtained when the pump laser has an electric field parallel (perpendicular) to the fiber axis, i.e., the polarization direction of output laser is the same as that of the pump laser. On the other hand, when the laser emission is single-mode, the TE output laser always emerges firstly above lasing threshold, then keeps TE mode while the pump laser’s intensity increases with polarization direction perpendicular to the fiber axis; on the contrary, TE emission will dwindle relatively, while the TM emission emerges and dominates the spectra, when the pump laser’s intensity increases with polarization parallel to the fiber axis. Our work proves that controlling the leakage of the evanescent wave from high-Q microcavities is crucial for both modes of lasing emission and its polarization.


2020 ◽  
Vol 109 ◽  
pp. 103427
Author(s):  
Chang Gaolei ◽  
Zhu Huan ◽  
Yu Chenren ◽  
Zhu Haiqing ◽  
Xu Gangyi ◽  
...  

2009 ◽  
Vol 29 (1) ◽  
pp. 95-105 ◽  
Author(s):  
A. Stocco ◽  
K. Tauer ◽  
S. Pispas ◽  
R. Sigel

1972 ◽  
Vol 11 (9) ◽  
pp. 1952 ◽  
Author(s):  
K. O. Hill ◽  
A. Watanabe ◽  
J. G. Chambers

Sign in / Sign up

Export Citation Format

Share Document