Robust estimation of between and within laboratory standard deviation with measurement results below the detection limit

2015 ◽  
Vol 10 (4) ◽  
pp. 385-391 ◽  
Author(s):  
Steffen Uhlig
2020 ◽  
Vol 12 (1) ◽  
pp. 804-812
Author(s):  
Świętoń Tomasz ◽  
Kadaj Roman ◽  
Oleniacz Grzegorz ◽  
Skrzypczak Izabela

AbstractProduction of prefabricated pipe spools for the needs of the oil and gas industry requires precise determination of their shape and dimensions. The crucial moment of production is to measure the spool being built, compare it with the design and define the geometry corrections that should be applied at the construction stage. At present, the comparison of spools is usually done in a manual manner in a CAD program or other software dedicated for this purpose and is implemented by combining variously defined translations and rotations. This approach is time-consuming and the results strongly depend on the survey engineer’s experience. In this article, a method of comparing the shape of two spools, based on isometric transformation and robust estimation, has been proposed. This method can be used to automate the comparison process. In standard approach, applied by both design engineers and assemblers, spools are described by a set of coordinates and, in the case of flanges, by sets of appropriately defined angular values. A method of flange description suitable for use in the isometric transformation process has been proposed, and potential problems that may appear at the implementation stage of the algorithm have been discussed. The proposed method makes it possible to determine the elements of a spool that do not fit into the design project in a way that allows minimizing the number of corrections at the construction stage.


2018 ◽  
Vol 33 (2) ◽  
pp. 47
Author(s):  
Orlando Fatibello-Filho ◽  
Heberth Juliano Vieira

A spectrophotometric flow injection method for the determination of paracetamol in pharmaceutical formulations is proposed. The procedure was based on the oxidation of paracetamol by sodium hypochloride and the determination of the excess of this oxidant using o-tolidine dichloride as chromogenic reagent at 430 nm. The analytical curve was linear in the paracetamol concentration range from 8.50 x 10-6 to 2.51 x 10-4 mol L-1 with a detection limit of 5.0 x 10-6 mol L-1. The relative standard deviation was smaller than 1.2% for 1.20 x 10-4 mol L-1 paracetamol solution (n = 10). The results obtained for paracetamol in pharmaceutical formulations using the proposed flow injection method and those obtained using a USP Pharmacopoeia method are in agreement at the 95% confidence level.


2009 ◽  
Vol 15 (2) ◽  
pp. 69-76 ◽  
Author(s):  
S.M. Al-Ghannam ◽  
A.M. Al-Olyan

A sensitive spectrophotometric method was developed for the determination of some 1,4-dihydropyridine compounds namely, nicardipine and isradipine either in pure form or in pharmaceutical preparations. The method is based on the reduction of nicardipine and isradipine with zinc powder and calcium chloride followed by further reduction with sodium pentacyanoaminoferrate (II) to give violet and red products having the absorbance maximum at 546 and 539 nm with nicardipine and isradipine, respectively. Beer's law was obeyed over the concentration range 8.0-180 ?g/ml with the detection limit of 1.67 ?g/ml for nicardipine and 8.0-110 ?g/ml with the detection limit of 1.748 ?g/ml for isradipine. The analytical parameters and their effects on the reported methods were investigated. The molar absorptivity, quantization limit, standard deviation of intercept (Sa), standard deviation of slope (Sb) and standard deviation of the residuals (Sy/x) were calculated. The composition of the result compounds were found 1:1 for nicardipine and 1:2 for isradipine by Job's method and the conditional stability constant (Kf) and the free energy changes (?G) were calculated for compounds formed. The proposed method was applied successfully for the determination of nicardipine and isradipine in their dosage forms. The results obtained were in good agreement with those obtained using the reference or official methods. A proposal of the reaction pathway was presented.


2012 ◽  
Vol 535-537 ◽  
pp. 1337-1340 ◽  
Author(s):  
Chi Yang ◽  
Nai Lin Ren

A new chemiluminescence system was built by using gadolinium as sensitizer, and the analysis capabilities of this system was tested as below. The method is based on chemluminescence of Ce (IV)-SO32- sensitized by Gd3+-OFLX. The effects of some critical experimental conditions were discussed and the optimum conditions for chemluminescence emission were investigated. The linear relationship between the relative chemiluminescence intensity and the concentration of OFLX is in the range of 2×10-9 g/mL~5×10-7 g/mL with a detection limit of 1.0×10-9g/mL .The relative standard deviation is 2.8% (n=11) for a level of 5.0×10-7 g/mL. The method has been applied to the analysis of OFLX in tablets with satisfactory results.


2002 ◽  
Vol 68 (1) ◽  
pp. 161-165 ◽  
Author(s):  
Ryan C. Kuhn ◽  
Channah M. Rock ◽  
Kevin H. Oshima

ABSTRACT Fecal samples were taken from wild ducks on the lower Rio Grande River around Las Cruces, N. Mex., from September 2000 to January 2001. Giardia cysts and Cryptosporidium oocysts were purified from 69 samples by sucrose enrichment followed by cesium chloride (CsCl) gradient centrifugation and were viewed via fluorescent-antibody (FA) staining. For some samples, recovered cysts and oocysts were further screened via PCR to determine the presence of Giardia lamblia and Crytosporidium parvum. The results of this study indicate that 49% of the ducks were carriers of Cryptosporidium, and the Cryptosporidium oocyst concentrations ranged from 0 to 2,182 oocysts per g of feces (mean ± standard deviation, 47.53 ± 270.3 oocysts per g); also, 28% of the ducks were positive for Giardia, and the Giardia cyst concentrations ranged from 0 to 29,293 cysts per g of feces (mean ± standard deviation, 436 ± 3,525.4 cysts per g). Of the 69 samples, only 14 had (oo)cyst concentrations that were above the PCR detection limit. Samples did test positive for Cryptosporidium sp. However, C. parvum and G. lamblia were not detected in any of the 14 samples tested by PCR. Ducks on their southern migration through southern New Mexico were positive for Cryptosporidium and Giardia as determined by FA staining, but C. parvum and G. lamblia were not detected.


2013 ◽  
Vol 699 ◽  
pp. 34-39
Author(s):  
Li Liu ◽  
Xia Shi Zhu

A new Triton X-114 cloud point extraction combined with fluorometry method for analysis of magnolol in drug samples was developed. Under the optimum conditions, the calibration graph was linear in the range of 2.0-150.0ng/mL of magnolol in the initial solution with r = 0.9998. Detection limit (DL) was 0.03ng/mL (S/N=3) and the relative standard deviation (RSD) for 20.0ng/mL of magnolol was 2.79%(n=11). The method was successfully applied for the determination of magnolol in drug samples with satisfactory results.


2019 ◽  
Vol 11 (4) ◽  
Author(s):  
Bambang Guruh Irianto ◽  
Agus Susilo Wibowo ◽  
Dwi Herry Andayani

A Bedside monitor is the equipment used to monitor patient condition through some parameters that need sustainable monitoring so that the patient condition is always monitored. This research is monitored by 5 parameters namely heart signal, heart rate, temperature, respiration and SPO2. This research applies quasi experimental design. The free variable is an ECG phantom or human, and the dependent variable is a bedside monitor. The research instruments are a calibration equipment of ECG signal, temperature, and respiration. The result of the heart signal lead 2 is not different from the standard and the result of the heart rate lead has uncertainty (probability) 0 for Lead 2; which is still under the tolerance number (0.5). The results of the temperature measurement of 5 samples with 5 measurements show that there are 3 samples which have standard deviation and 0 (zero) uncertainty, whereas 2 samples have 0.76 (higher than 0.5) uncertainty. This condition is influenced by the patient movements, so the sensor attached on the patient-body does not fit with the standard installation. The respiration measurement results have an accuracy of 98%, while the SPO2 results have a standard deviation and uncertainty below 5% after being compared with the standard calculations. Here are the details: standard deviation 0.894427; 0.547723; 0.44; Probability 0.4; 0.244949; 0.2 and 0.2. Overall, it can be concluded that The Design of  Bedside Monitor Based on Microcontroller is feasible and the measurement result of heart signal Lead 2, heart rate, temperature, respiration, SPO2 can be presented on a PC.


1990 ◽  
Vol 29 (04) ◽  
pp. 413-423 ◽  
Author(s):  
P. Rubel ◽  
J. L. Willems ◽  
D. Morlet

AbstractA new method is presented, different from usual methods, for the discussion of the results of computer ECG measurement programs, based on a new graphical evaluation method. The proposed “scatter-graphs” both highlight the main program results and facilitate the comparison between various wave-recognition algorithms. They allow the distinction between the reliability of an algorithm, which is its capacity to provide a maximum of measurements with a minimum amount of errors, and its precision, i.e., the standard deviation of the differences between its point estimates and the reference.The method proves to be a powerful tool for the discussion of individual, as well as the median program results in CSE Measurement Study. It allows to highlight limitations induced in performance assessment by the variability of the reference itself, and to state that the median program is at least as close to the “Gold Standard” as the median of the referees.


Sign in / Sign up

Export Citation Format

Share Document