scholarly journals Flow Diversion for Treatment of Acutely Ruptured Intracranial Aneurysms

2019 ◽  
Vol 30 (4) ◽  
pp. 835-842 ◽  
Author(s):  
Muhammad AlMatter ◽  
Marta Aguilar Pérez ◽  
Victoria Hellstern ◽  
Goran Mitrovic ◽  
Oliver Ganslandt ◽  
...  

Abstract Background Reports about the use of flow diverter stents (FDS) in the acute setting of subarachnoid hemorrhage (SAH) are limited. This article presents a single center experiences based on 45 consecutive cases with emphasis on complication rates and clinical and radiologic outcomes. Methods A prospectively maintained database of all cases treated with FDS as a stand-alone or adjunct device was retrospectively reviewed. All patients treated within 30 days of SAH were included. Records were made of clinical presentation, details of endovascular treatment, procedural complications, clinical outcome, and degree of occlusion on follow-up. Results In this study 45 patients (48.9% females; mean age 58.8 ± 12.4 years) were included. Flow diversion was performed after a median of 4 days. The procedural complication rate was 13.3% resulting in 2.2% permanent morbidities and 4.4% mortalities. No major hemorrhagic complications related to antiplatelet therapy were recorded. Immediate complete occlusion was achieved in 13.3%. Among survivors, complete occlusion was achieved in 94.6%. Excellent clinical outcome was recorded in 68.9% and 81.6% of the total population and survivors, respectively. There were no records of rebleeding from the target lesions. Conclusion Flow diversion is an attractive alternative strategy for management of acutely ruptured aneurysms with high rates of delayed complete occlusion and acceptable complication rates.

2014 ◽  
Vol 20 (4) ◽  
pp. 428-435 ◽  
Author(s):  
Willem Jan van Rooij ◽  
Ratna S Bechan ◽  
Jo P. Peluso ◽  
Menno Sluzewski

Flow diverter devices became available in our department in 2009. We considered treatment with flow diverters only in patients with aneurysms not suitable for surgery or conventional endovascular techniques. This paper presents our preliminary experience with flow diverters in a consecutive series of 550 endovascular aneurysm treatments. Between January 2009 and July 2013, 550 endovascular treatments for intracranial aneurysms were performed. Of these, 490 were first-time aneurysm treatments in 464 patients and 61 were additional treatments of previously coiled aneurysms in 51 patients. Endovascular treatments consisted of selective coiling in 445 (80.8%), stent-assisted coiling in 68 (12.4%), balloon-assisted coiling in 13 (2.4%), parent vessel occlusion in 12 (2.2%) and flow diverter treatment in 12 (2.2%). Eleven patients with 12 aneurysms were treated with flow diverters. Two patients had ruptured dissecting aneurysms. One patient with a basilar trunk aneurysm died of acute in stent thrombosis and another patient died of brain stem ischaemia at 32 months follow-up. One patient had ischaemia with permanent neurological deficit. Two aneurysms are still open at up to 30 months follow-up. Flow diversion was used in 2% of all endovascular treatments. Both our own poor results and the high complication rates reported in the literature have converted our initial enthusiasm to apprehension and hesitancy. The safety and efficacy profile of flow diversion should discourage the use of these devices in aneurysms that can be treated with other techniques.


2021 ◽  
pp. 1-8
Author(s):  
José E. Cohen ◽  
J. Moshe Gomori ◽  
Samuel Moscovici ◽  
Andrew H. Kaye ◽  
Yigal Shoshan ◽  
...  

OBJECTIVE Flow-diverter stents (FDSs) are not generally used for the management of acutely ruptured aneurysms with associated subarachnoid hemorrhage (SAH). Herein, the authors present their experience with FDSs in this scenario, focusing on the antiplatelet regimen, perioperative management, and outcome. METHODS The authors retrospectively reviewed their institutional database for the treatment and outcomes of all patients with acutely ruptured aneurysms and associated SAH from July 2010 to September 2018 who had received an FDS implant as stand-alone treatment within 4 days after diagnosis. The protocol with the use of flow diversion in these patients includes a low threshold for placement of external ventricular drains before stenting, followed by the administration of aspirin and clopidogrel with platelet testing before stent implantation. With this approach, the risk of hemorrhage and stent-related thrombus formation is limited. Demographic, clinical, technical, and imaging data were analyzed. RESULTS Overall, 76 patients (61% females, mean age 42.8 ± 11.3 years) met the inclusion criteria. FDS implantation was performed a median of 2 days after diagnosis. On average, 1.05 devices were used per procedure. There was no procedural mortality directly attributed to the endovascular intervention. Procedural device-related clinical complications were recorded in a total of 6 cases (7.9%) and resulted in permanent neurological morbidity in 2 cases (2.6%). There was complete immediate aneurysm occlusion in 11 patients (14.5%), and persistent aneurysm filling was seen in 65 patients (85.5%). Despite this, no patient presented with rebleeding from the target aneurysm. There was an excellent clinical outcome in 62 patients (81.6%), who had a 90-day modified Rankin Scale score of 0–2. Among the 71 survivors, total or near-total occlusion was observed in 64/67 patients (95.5%) with a 3- to 6-month angiographic follow-up and in all cases evaluated at 12 months. Five patients (6.6%) died during follow-up for reasons unrelated to the procedure or new hemorrhage. CONCLUSIONS Flow diversion is an effective therapeutic strategy for the management of select acutely ruptured aneurysms. Despite low rates of immediate aneurysm occlusion after FDS implantation, the device exerts an important protective effect. The authors’ experience confirmed no aneurysm rerupture, high rates of delayed complete occlusion, and complication rates that compare favorably with the rates obtained using other techniques.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
E Androulakis ◽  
A Briasoulis ◽  
D Falconer ◽  
W Lim ◽  
G Siasos ◽  
...  

Abstract Background In the past decade, catheter ablation (CA) has become a rapidly expanding treatment option for ventricular tachycardia (VT), however it is not commonly utilized for patients with post-myocarditis VT. We aimed to systematically review up-to-date evidence regarding feasibility, effectiveness, and safety of CA, with a specific focus on long-term relapse rate and procedural complications. Methods A structured electronic database search (PubMed, Embase, Cochrane) of the scientific literature was performed for studies describing outcomes at up to 7.3 years after CA. The primary outcome measured was VT recurrence post-ablation. Procedural success was defined as freedom of ventricular arrhythmias (at the end of follow-up after an ablation procedure). The secondary outcome was significant procedural complications which included procedural death, stroke, cardiac tamponade, acute myocardial infarction, major vascular complications, and major bleeding, assessed on a study-by-study basis. Results A total of 186 patients were included in analysis with most patients (88%) being male. Over the follow up period there was a 18% relapse rate (n=34) (Confidence Interval (CI); 0.12–0.24, I2≈0, p=0.77) with the majority of patients remaining VT free for the duration of follow up. Only one study recorded the percentage of re-do procedures. The overall procedural complication rate was 3.0% (n=7, (CI; 0.01–0.07, I2≈0, p=0.44) and of note, there were no peri-procedural deaths or heart transplant surgeries reported. However, a single study reported a mortality of 10% (n=2) during the follow up period. Conclusions CA is an effective and durable long-term therapeutic strategy for post myocarditis VT patients with limited relapse rate and very low complication rates based on these non-randomised data. Larger randomised-controlled trials with standardised treatment and long follow-up are required to compare CA versus conventional treatment in the post-acute myocardial phase. FUNDunding Acknowledgement Type of funding sources: None. Relapse rate during follow-up Procedural complication rate


2019 ◽  
Vol 3 (1) ◽  
Author(s):  
Tim Lenz-Habijan ◽  
Pervinder Bhogal ◽  
Catrin Bannewitz ◽  
Ralf Hannes ◽  
Hermann Monstadt ◽  
...  

Abstract Background Flow diverters (FDs) are widely used in the treatment of intracranial aneurysms, but the required medication increases the risk of haemorrhagic complications and limits their use in the acute setting. Surface modified FDs may limit the need for dual antiplatelet therapy (DAPT). Hydrophilic polymer coating (HPC) may reduce the need of medication. Methods This explorative study, approved by the local authorities and the local welfare committee, compared stent behaviour and overall tissue response between HPC-coated FDs and uncoated FDs, both implanted into the common carotid arteries of eight New Zealand white rabbits. Endothelialisation, inflammatory response, and performance during implantation were assessed. Angiographic follow-up was performed to observe the patency of the devices after implantation and after 30 days. Histological examinations were performed at 30 days to assess foreign body reaction and endothelialisation. Kruskal-Wallis and Wilcoxon tests were used to compare non-parametric variables. Results Angiography showed that both coated and uncoated FDs performed well during implantation. All devices remained patent during immediate follow-up and after 30 days. Histopathology showed no significant difference in inflammation within the vessel wall between the two cohorts (2.12 ± 0.75 vs. 1.96 ± 0.79, p = 0.7072). Complete endothelialisation of the stent struts was seen with very similar (0.04 ± 0.02 mm vs. 0.04 ± 0.03 mm, p = 0.892) neoendothelial thickness between the two cohorts after 30 days. Conclusion Taking into account the limitation in sample size, non-significant differences between the HPC-coated and uncoated FDs regarding implantation, foreign body response, and endothelialisation were found.


2021 ◽  
pp. 159101992110279
Author(s):  
Muhammad Waqas ◽  
Rimal H Dossani ◽  
Modhi Alkhaldi ◽  
Jocelyn Neveu ◽  
Justin M Cappuzzo ◽  
...  

Introduction The Flow Redirection Endoluminal Device (FRED; MicroVention) is a dual-layered flow diverter used for the treatment of intracranial aneurysms. The objective of this systematic review was to compile device-related safety and effectiveness data. Methods The literature from January 1, 2013 to April 30, 2021 was searched for studies describing use of the FRED for intracranial aneurysm treatment irrespective of aneurysm location and morphology. The review included anterior and posterior circulation ruptured and unruptured saccular, fusiform or dissection, and blister aneurysms. MeSH terms related to “flow re-direction endoluminal device” and “FRED for aneurysms” were used. Data related to indication, complications, and rates of aneurysm occlusion were retrieved and analyzed. Results Twenty-two studies with 1729 intracranial aneurysms were included in this review. Overall reported morbidity was 3.9% (range 0–20%). Overall procedure-related mortality was 1.4% (range 0–6%). Complication rates fell into 5 categories: technical (3.6%), ischemic (3.8%), thrombotic or stenotic (6%), hemorrhagic (1.5%), and non-neurological (0.8%). The aneurysm occlusion rate between 0 and 3 months (reported in 11 studies) was 47.8%. The occlusion rate between 4 and 6 months (reported in 14 studies) was 73.8%. Occlusion rates continued to increase to 75.1% at 7–12 months (reported in 10 studies) and 86.6% for follow-up beyond 1 year (reported in 10 studies). Conclusion This review indicated that the FRED is a safe and effective for the treatment of intracranial aneurysms. Future studies should directly compare the FRED with other flow diverters for a better understanding of comparative safety and effectiveness among the different devices.


2021 ◽  
pp. 1-6
Author(s):  
Thomas Huang ◽  
Edward O’Leary ◽  
Mark E. Alexander ◽  
Laura Bevilacqua ◽  
Francis Fynn-Thompson ◽  
...  

Abstract Introduction: Reflex-mediated syncope occurs in 15% of children and young adults. In rare instances, pacemakers are required to treat syncopal episodes associated with transient sinus pauses or atrioventricular block. This study describes a single centre experience in the use of permanent pacemakers to treat syncope in children and young adults. Materials and methods: Patients with significant pre-syncope or syncope and pacemaker implantation from 1978 to 2018 were reviewed. Data collected included the age of presentation, method of diagnosis, underlying rhythm disturbance, age at implant, type of pacemaker implanted, procedural complications and subsequent symptoms. Results: Fifty patients were identified. Median age at time of the first syncopal episode was 10.2 (range 0.3–20.4) years, with a median implant age of 14.9 (0.9–34.3) years. Significant sinus bradycardia/pauses were the predominant reason for pacemaker implant (54%), followed by high-grade atrioventricular block (30%). Four (8%) patients had both sinus pauses and atrioventricular block documented. The majority of patients had dual-chamber pacemakers implanted (58%), followed by ventricular pacemakers (38%). Median follow-up was 6.7 (0.4–33.0) years. Post-implant, 4 (8%) patients continued to have syncope, 7 (14%) had complete resolution of their symptoms, and the remaining reported a decrease in their pre-syncopal episodes and no further syncope. Twelve (24%) patients had complications, including two infections and eight lead malfunctions. Conclusions: Paediatric patients with reflex-mediated syncope can be treated with pacing. Complication rates are high (24%); as such, permanent pacemakers should be reserved only for those in whom asystole from sinus pauses or atrioventricular block has been well documented.


2018 ◽  
Vol 25 (2) ◽  
pp. 182-186
Author(s):  
Manoj Bohara ◽  
Kosuke Teranishi ◽  
Kenji Yatomi ◽  
Takashi Fujii ◽  
Takayuki Kitamura ◽  
...  

Background Flow diversion with the Pipeline embolization device (PED) is a widely accepted treatment modality for aneurysm occlusion. Previous reports have shown no recanalization of aneurysms on long-term follow-up once total occlusion has been achieved. Case description We report on a 63-year-old male who had a large internal carotid artery cavernous segment aneurysm. Treatment with PED resulted in complete occlusion of the aneurysm. However, follow-up angiography at four years revealed recurrence of the aneurysm due to disconnection of the two PEDs placed in telescoping fashion. Conclusion Herein, we present the clinico-radiological features and discuss the possible mechanisms resulting in the recanalization of aneurysms treated with flow diversion.


Author(s):  
Ossama Y Mansour ◽  
Aser Goma

Introduction : Acute dissecting aneurysms are among the uncommon causes of subarachnoid hemorrhage. Established endovascular treatment options include parent artery occlusion and stent‐assisted coiling, but appear to be associated with an increased risk of ischemic stroke. reconstruction of the vessels with flow diverters is an alternative therapeutic option. Methods : This is a retrospective analysis of 53 consecutive acutely ruptured dissecting aneurysms treated with flow diverters. The primary end point was favorable aneurysm occlusion, defined as OKM C1‐3 and D . Secondary end points were procedure‐related complications and clinical outcome. Results : 23 aneurysms (43.4%%) arose from the intradural portion of the vertebral artery, 10 (18.8%) were located on the posterior inferior cerebellar artery and 3 (5.6%) posterior cerebral artery, 7 (13.2%) MCA, (18.8%) ICA . 45 aneurysms presented by SAH while 8 presented by Ischemic manifestation. Flow diverter placement was technically successful in all cases . immediate postoperative rerupture occurred in two case (3.7%), thromboembolic complications in 3 cases (5.7%). Median clinical follow‐up was 640 days and median angiographic follow‐up was 690 days. ten patients (18.9%) with poor‐grade subarachnoid hemorrhage died in the acute phase. Favorable clinical outcome (modified Rankin scale ≤2) was observed in 27 of 53 patients (51%) and a moderate outcome (modified Rankin scale 3/4) was observed in 12 of 53 patients (22.6%). All aneurysms showed complete occlusion at follow‐up. Conclusions : Flow diverters might be a feasible, alternative treatment option for acutely symptomatic dissecting aneurysms and may effectively prevent rebleeding in ruptured aneurysms.


Neurosurgery ◽  
2019 ◽  
Vol 86 (Supplement_1) ◽  
pp. S21-S34 ◽  
Author(s):  
Georgios A Maragkos ◽  
Adam A Dmytriw ◽  
Mohamed M Salem ◽  
Vincent M Tutino ◽  
Hui Meng ◽  
...  

Abstract Over the past decade, flow diverter technology for endocranial aneurysms has seen rapid evolution, with the development of new devices quickly outpacing the clinical evidence base. However, flow diversion has not yet been directly compared to surgical aneurysm clipping or other endovascular procedures. The oldest and most well-studied device is the Pipeline Embolization Device (PED; Medtronic), recently transitioned to the Pipeline Flex (Medtronic), which still has sparse data regarding outcomes. To date, other flow diverting devices have not been shown to outperform the PED, although information comes primarily from retrospective studies with short follow-up, which are not always comparable. Because of this lack of high-quality outcome data, no reliable recommendations can be made for choosing among flow diversion devices yet. Moreover, the decision to proceed with flow diversion should be individualized to each patient. In this work, we wish to provide a comprehensive overview of the technical specifications of all flow diverter devices currently available, accompanied by a succinct description of the evidence base surrounding each device.


2019 ◽  
Vol 11 (9) ◽  
pp. 903-907 ◽  
Author(s):  
Christopher T Primiani ◽  
Zeguang Ren ◽  
Peter Kan ◽  
Ricardo Hanel ◽  
Vitor Mendes Pereira ◽  
...  

BackgroundIntracranial aneurysms located in the distal vessels are rare and remain a challenge to treat through surgical or endovascular interventions.ObjectiveTo describe a multicenter approach with flow diversion using the pipeline embolization device (PED) for treatment of distal intracranial aneurysms.MethodsCases of distal intracranial aneurysms defined as starting on or beyond the A2 anterior cerebral artery, M2 middle cerebral artery, and P2 posterior cerebral artery segments were included in the final analysis.Results65 patients with distal aneurysms treated with the PED were analyzed. Median aneurysm size at the largest diameter was 7.0 mm, 60% were of a saccular morphology, and 9/65 (13.8%) patients presented in the setting of acute rupture. Angiographic follow-up data were available for 53 patients, with a median follow-up time of 6 months: 44/53 (83%) aneurysms showed complete obliteration, 7/53 (13.2%) showed reduced filling, and 2/53 (3%) showed persistent filling. There was no association between patient characteristics, including aneurysm size (P=0.36), parent vessel diameter (P=0.27), location (P=0.81), morphology (P=0.63), ruptured status on admission (P=0.57), or evidence of angiographic occlusion at the end of the embolization procedure (P=0.49). Clinical outcome data were available for 60/65 patients: 95% (57/60) had good clinical outcome (modified Rankin Scale score of 0–2) at 3 months.ConclusionsThis large multicenter study of patients with A2, M2, and P2 distal aneurysms treated with the PED showed that flow diversion may be an effective treatment approach for this rare type of vascular pathology. The procedural compilation rate of 7.7% indicates the need for further studies as the flow diversion technology constantly evolves.