scholarly journals Correction to: Environmental temperature and relative humidity differently affect the sperm characteristics in Brown Swiss and Belgian Blue bulls

Author(s):  
Alessia Gloria ◽  
Luca Candeloro ◽  
Laura Wegher ◽  
Domenico Robbe ◽  
Augusto Carluccio ◽  
...  
2009 ◽  
Vol 52 (5) ◽  
pp. 459-465
Author(s):  
B. Bülbül ◽  
M. B. Ataman

Abstract. In this study, the effect of climatic conditions on oestrus occurrence was investigated by using 9 972 oestrus records of cows recorded between 1995 and 2003. A distinct seasonal variation in the oestrus occurrence was determined. Oestrus occurrence observed in January, March, November and December was less than that in June and September (P<0.05). Annual distribution of the oestrus occurrence was positively correlated with environment temperature and insulation duration, but it was negatively correlated with rainfall (P<0.01). However, there was no relationship between oestrus occurrence and relative humidity. In addition to these, there was a slight decrease in the oestrus response when the temperature-humidity index (THI) was above 72; nevertheless, this decrease was not significant (P >0.05). The data presented in this study demonstrated that the increase in the environmental temperature up to 23 °C did not cause a suppressive effect on the ovarian activity. In conclusion, annual distribution of the oestrus occurrence is positively correlated with environment temperature and insulation duration whereas it is negatively correlated with rainfall in Holstein cows, in this study.


1967 ◽  
Vol 6 (46) ◽  
pp. 505-514 ◽  
Author(s):  
J. Latham ◽  
C. P. R. Saunders

AbstractThe forceFrequired to separate two ice spheres was measured as a function of environmental temperatureT, relative humidityHand the strengthEof the external electric field in which the spheres were situated. It was found that over the entire attainable range ofTandH,Fincreased rapidly with increasingE. The increased adhesion was not accompanied by an increase in the rate of growth of the ice bridge between the two spheres and is explicable in terms of Davis’s (1964) calculations of the purely electrostatic forces between two spheres situated in an electric field. The experiments indicate that the rate of growth of snowflakes in a cloud by means of ice crystal aggregation will be markedly enhanced if the cloud is highly electrified.


2014 ◽  
Vol 42 (01) ◽  
pp. 13-19 ◽  
Author(s):  
B. D. Kruse ◽  
R. Müller ◽  
C. Stockhaus ◽  
K. Hartmann ◽  
A. Wehner ◽  
...  

Summary Objective: Measurement of rectal temperature is the most common method and considered gold standard for obtaining body temperature in dogs. So far, no study has been performed comparing agreement between rectal and auricular measurements in a large case series. The purpose of the study was to assess agreement between rectal and auricular temperature measurement in normothermic, hypothermic, and hyperthermic dogs with consideration of different environmental conditions and ear conformations. Materials and methods: Reference values for both methods were established using 62 healthy dogs. Three hundred dogs with various diseases (220 normothermic, 32 hypothermic, 48 hyperthermic) were enrolled in this prospective study. Rectal temperature was compared to auricular temperature and differences in agreement with regard to environmental temperature, relative humidity, and different ear conformations (pendulous versus prick ears) were evaluated using Pearson’s correlation coefficient and Bland-Altman analysis. Results: Correlation between rectal and auricular temperature was significant (r: 0.892; p < 0.01). However, Bland-Altman plots showed an inacceptable variation of values (bias: 0.300 °C; limits of agreement: –0.606 to 1.206 °C). This variation was above a maximal clinical tolerance of 0.3 °C, which was established by experts’ opinion (n = 16). Relative humidity had a significant influence (p = 0.001), whereas environmental temperature did not. Conclusion: Variation between the two methods of measuring body temperature was clinically unacceptable. Clinical relevance: Although measurement of auricular temperature is fast, simple, and well tolerated, this method provides a clinically unacceptable difference to the rectal measurement.


1994 ◽  
Vol 142 (1) ◽  
pp. 153-160 ◽  
Author(s):  
S M Kisliuk ◽  
R Grossmann

Abstract The influence of low humidity during incubation (LHI) on arginine vasotocin (AVT) secretion in male and female White Leghorn chicken embryos and chicks was investigated. LHI embryos were incubated from day 8 (E8) to E18 at a relative humidity of 32–35%, while control embryos were incubated at 58–62%. In the control groups, plasma AVT gradually increased from E15 to E18, increased sharply during hatching and returned to the El8 level within 4 h. LHI did not alter the level of AVT until E18. LHI E19 males had concentrations of AVT twice as high as those of control males (39 ± 3·9 vs 15 ± 1·6 pmol/l, P<0·001). Augmentation persisted during hatching and 4 h afterwards. In LHI females additional elevation reached significant levels only at 4 h after hatching (58 ± 13 vs 16 ± 1·7 pmol/l, P<0·01). Deprivation of water caused an increase in plasma sodium concentrations in the 2-day-old chicks of the control groups, while no significant changes were observed in the LHI group. Deprivation of water together with a high environmental temperature caused an additional increase in AVT only in the LHI groups (42 ± 5·2 vs 22 ± 3·9 pmol/l, P<0·01 for males; 32 ± 3·4 vs 19 ± 2·8 pmol/l, P<0·01 for females). The results clearly showed that LHI leads to a more pronounced response of the AVT system on subsequent osmotic and non-osmotic challenges, especially in males. Embryonal activation of the AVT system probably helps the organism to cope with hatching and posthatching stresses. Journal of Endocrinology (1994) 142, 153–160


Author(s):  
Zhanxiao Kang ◽  
Xianfu Wan ◽  
Faming Wang ◽  
Uday Raj ◽  
Bin Yang

The hybrid personal cooling system (HPCS) consisted of ventilation fans and phase change materials (PCMs) covered with insulation pads is a promising wearable cooling system to mitigate heat strain and heat-related illnesses of occupational workers with heavy labor in hot environments. Effects of clothing characteristics (e.g., thermal resistance of insulation pads, latent heat and melting temperature of PCMs) on the thermal performance of the HPCS have been investigated in detail in our previous study. Apart from the aforementioned factors, environmental conditions, i.e., environmental temperature and relative humidity, also significantly affect the thermal performance of the HPCS. In this paper, a numerical parametric study was performed to investigate the effects of the environmental temperature and relative humidity (RH) on the thermal management of the HPCS. Five levels of air temperature under environmental RH=50% were chosen (i.e., 32, 34, 36, 38 and 40 ºC) to study the impact of environmental temperature on the HPCS’s cooling performance. In addition, four levels of environmental RH at ambient temperatures of 36 and 40 ºC were selected (i.e., 30, 50, 70 and 90%) to examine the effect of RH on cooling performance of the HPCS. Results show that high environmental temperatures could accelerate the PCM melting process and thereby weaken the cooling performance of HPCS. In the moderately hot environment (36 °C), the HPCS presented good cooling performance with the maximum core temperature at around 37.5 °C during excise when the ambient RH≤70%, whereas good cooling performance could be only seen under RH≤50% in the extremely hot environment (40 °C). Thus, it may be concluded that the maximum environmental RH for the HPCS exhibiting good cooling performance decreases with the increase in the environmental temperature.


Sign in / Sign up

Export Citation Format

Share Document