scholarly journals Energy balance closure and advective fluxes at ADVEX sites

2020 ◽  
Vol 143 (1-2) ◽  
pp. 761-779
Author(s):  
Uta Moderow ◽  
Thomas Grünwald ◽  
Ronald Queck ◽  
Uwe Spank ◽  
Christian Bernhofer

AbstractWhen measuring the energy balance at the earth’s surface using the Eddy covariance technique, the obtained budgets seldom produce a closed energy balance. The measurements often miss some of the energy fluxes. A possible reason is the neglect of non-turbulent surface fluxes of latent heat and sensible heat, i.e. advective fluxes of these quantities. We present estimates of advective latent and sensible heat fluxes for three different sites across Europe based on the ADVEX dataset. The obtained horizontal and vertical advective fluxes were site-specific and characterized by large scatter. In relative terms, the data indicated that the sensible heat budget was less affected by advection than the latent heat budget during nighttime; this is because vertical turbulent latent heat fluxes were very small or close to zero during the night. The results further showed that the additional energy gain by sensible heat advection might have triggered enhanced evaporation for two sites during nighttime. Accounting for advective fluxes improved the energy balance closure for one of the three ADVEX sites. However, the energy balance closure of the other two sites did not improve overall. A comparison with energy balance residuals (energy missed by the measurements without accounting for advection) indicated a large influence of systematic errors. An inspection of the energy balance for the sloped site of the ADVEX dataset underlined the necessity of slope-parallel measurement of radiation.

2016 ◽  
Author(s):  
Nobuhle P. Majozi ◽  
Chris M. Mannaerts ◽  
Abel Ramoelo ◽  
Renaud Mathieu ◽  
Alecia Nickless ◽  
...  

Abstract. Flux tower sites and data are in great demand to provide essential terrestrial climate, water and radiation budget information needed for environmental monitoring and evaluation of climate change impacts on ecosystems and society in general. They are also intended for calibration and validation of satellite-based earth observation and monitoring efforts, such as for example assessment of evapotranspiration from land and vegetation surfaces using surface energy balance approaches. Surface energy budget methods for ET estimation rely to a large extend on the basic assumption of a surface energy balance closure, assuming the full conversion of net solar radiation reaching the land surface into soil heat conduction and turbulent fluxes, i.e. the sensible (or convection) and latent heat components of the energy balance. Evapotranspiration is the conversion of the latent heat exchange fraction of the balance. In this paper, the Skukuza flux tower data were analysed in order to verify their use for validation of satellite–based evapotranspiration methods, under development in South Africa.Data series from 2000 until 2014 were used in the analysis. The energy balance ratio (EBR) concept, defined as the ratio between the sum of the turbulent convective and latent heat fluxes and radiation minus soil heat was used. At first typical diurnal patterns of EB partitioning were derived for four different seasons, well illustrating how this savannah-type biome responses to the weather conditions. Also the particular behaviour of the EB components during sunrise and sunset conditions, being important but usually neglected periods of energy transitions and inversions were noted and analysed. Annual estimates of the surface energy balance and its components were generated, including an evaluation of the balance closure. The seasonal variations were also investigated as well as the impact of nocturnal observations on the overall EB behaviour.


2020 ◽  
Author(s):  
Matěj Orság ◽  
Milan Fischer ◽  
Josef Eitzinger ◽  
Miroslav Trnka

<p>In this study we compare turbulent energy fluxes obtained from eddy covariance (EC) (LI-7500A, LI-COR + Windmaster, Gill Instruments) and large aperture scintillometer (BLS900, Scintec) over an agricultural field (wheat field, straw and bare soil). As the EC method provides direct measurements of sensible heat (H<sub>EC</sub>) and latent heat (LE<sub>EC</sub>) fluxes we use it as a reference method. The EC method enables to determine fluxes within a footprint centered around the point of measurement in the middle of the field. The scintillometer provides an estimation of sensible heat flux (H<sub>SC</sub>), derived from air refractive index fluctuation integrated over the measurement path length, in this case 570 m diagonally across whole field. The reference measurements of the radiation balance components consist of 4-component net radiometer for net radiation (Rn) (NR01, Hukseflux), three soil heat flux plates for soil heat flux (G) monitoring (HFP01, Hukseflux), including thermocouples for quantification of the heat storage above the soil heat flux plates. The scintillometer-based latent heat (LE<sub>SC</sub>) is calculated as a residuum from available energy (Rn-G) and H<sub>SC</sub>, provided by scintillometer. The measurement of radiation balance components was located at the top of 3.5 m mast with the EC system, while the soil heat flux plates were collocated around in 5 cm depth. The site is a flat, rectangular agricultural field (app. 16.5 ha), in the north-eastern Austria, Danube river lowland (48.21N, 16.622E), sown with winter wheat during growing season 2019. The measurement campaign was established in February 2019 with aim for multi-seasonal monitoring. The EC measurement height is 2.7 m, the scintillometer transmitter and receiver are fixed on 4 m masts, facing towards each other from NW and SE corners of the field.</p><p>Comparison of the EC-based turbulent fluxes (H<sub>EC</sub>+LE<sub>EC</sub>) and the available energy (Rn-G) during the period March to Mid-June showed a very good agreement, resulting in the energy balance closure of 0.96 (R<sup>2 </sup>= 0.93). This suggest high accuracy and robustness of the measurement setup together with the ability of the EC method to capture all scales of eddies responsible for energy transport at this site. The comparison of methods indicates that H<sub>SC</sub> overestimated H<sub>EC</sub> by 10 % (R<sup>2 </sup>= 0.74) and LE<sub>SC</sub> underestimated LE<sub>EC</sub> by 13 % (R<sup>2 </sup>= 0.81). Related to Rn, the H<sub>EC</sub>, LE<sub>EC</sub> and G fluxes accounted for 22 % (R<sup>2 </sup>= 0.53), 59 % (R<sup>2 </sup>= 0.70) and 15% (R<sup>2 </sup>= 0.62) of the Rn flux, respectively. We assume that the combination of EC and scintillometer method has a potential to bring deeper insight into the analysis of the energy balance closure problem.</p>


2020 ◽  
Author(s):  
Luise Wanner ◽  
Frederik De Roo ◽  
Matthias Mauder

<p>The eddy-covariance method generally underestimates sensible and latent heat fluxes, resulting in an energy-balance gap from 10 % to even 30 % across sites worldwide. In contrast to single-tower eddy-covariance measurements, large-eddy simulations (LES) provide information on a 3D array of grid points and can capture atmospheric processes such as secondary circulations on all relevant scales, which makes them a powerful tool to investigate this problem. In order to compare LES results to field measurements at 20 m height from the CHEESEHEAD (Chequamegon Heterogeneous Ecosystem Energy-balance Study Enabled by a High-density Extensive Array of Detectors) campaign, a LES-setup that provides comparability to the measurements at these low levels is necessary. However, former LES studies have shown that the energy balance is almost closed near the surface, which does not reflect the energy-balance gap in measurements. One possible reason might be the common use of prescribed surface fluxes that cannot adapt to changes in surface temperature and moisture, which would allow for the self-reinforcement of secondary circulations. Therefore, we set up an idealized study, in which we compare the performance of the land-surface and plant-canopy models implemented in PALM to the use of prescribed surface fluxes above homogeneous forest and grassland ecosystems under different atmospheric conditions with respect to realistic energy-balance closure behavior. Furthermore, we evaluate the performance of a dynamic subgrid-scale model, as well as an alternative to the Monin-Obukhov similarity theory (Banerjee et al. 2015, Q. J. R. Met. Soc.).</p>


2013 ◽  
Vol 17 (14) ◽  
pp. 1-22 ◽  
Author(s):  
Allison L. Steiner ◽  
Dori Mermelstein ◽  
Susan J. Cheng ◽  
Tracy E. Twine ◽  
Andrew Oliphant

Abstract Atmospheric aerosols scatter and potentially absorb incoming solar radiation, thereby reducing the total amount of radiation reaching the surface and increasing the fraction that is diffuse. The partitioning of incoming energy at the surface into sensible heat flux and latent heat flux is postulated to change with increasing aerosol concentrations, as an increase in diffuse light can reach greater portions of vegetated canopies. This can increase photosynthesis and transpiration rates in the lower canopy and potentially decrease the ratio of sensible to latent heat for the entire canopy. Here, half-hourly and hourly surface fluxes from six Flux Network (FLUXNET) sites in the coterminous United States are evaluated over the past decade (2000–08) in conjunction with satellite-derived aerosol optical depth (AOD) to determine if atmospheric aerosols systematically influence sensible and latent heat fluxes. Satellite-derived AOD is used to classify days as high or low AOD and establish the relationship between aerosol concentrations and the surface energy fluxes. High AOD reduces midday net radiation by 6%–65% coupled with a 9%–30% decrease in sensible and latent heat fluxes, although not all sites exhibit statistically significant changes. The partitioning between sensible and latent heat varies between ecosystems, with two sites showing a greater decrease in latent heat than sensible heat (Duke Forest and Walker Branch), two sites showing equivalent reductions (Harvard Forest and Bondville), and one site showing a greater decrease in sensible heat than latent heat (Morgan–Monroe). These results suggest that aerosols trigger an ecosystem-dependent response to surface flux partitioning, yet the environmental drivers for this response require further exploration.


2010 ◽  
Vol 7 (1) ◽  
pp. 301-313 ◽  
Author(s):  
A. Lindroth ◽  
M. Mölder ◽  
F. Lagergren

Abstract. Temperature measurements in trunks and branches in a mature ca. 100 years-old mixed pine and spruce forest in central Sweden were used to estimate the heat storage in the tree biomass. The estimated heat flux in the sample trees and data on biomass distributions were used to scale up to stand level biomass heat fluxes. The rate of change of sensible and latent heat storage in the air layer below the level of the flux measurements was estimated from air temperature and humidity profile measurements and soil heat flux was estimated from heat flux plates and soil temperature measurements. The fluxes of sensible and latent heat from the forest were measured with an eddy covariance system in a tower. The analysis was made for a two-month period in summer of 1995. The tree biomass heat flux was the largest of the estimated storage components and varied between 40 and −35 W m−2 on summer days with nice weather. Averaged over two months the diurnal maximum of total heat storage was 45 W m−2 and the minimum was −35 W m−2. The soil heat flux and the sensible heat storage in air were out of phase with the biomass flux and they reached maximum values that were about 75% of the maximum of the tree biomass heat storage. The energy balance closure improved significantly when the total heat storage was added to the turbulent fluxes. The slope of a regression line with sum of fluxes and storage as independent and net radiation as dependent variable, increased from 0.86 to 0.95 for half-hourly data and the scatter was also reduced. The most significant finding was, however, that during nights with strongly stable conditions when the sensible heat flux dropped to nearly zero, the total storage matched the net radiation very well. Another interesting result was that the mean energy imbalance started to increase when the Richardson number became more negative than ca. −0.1. In fact, the largest energy deficit occurred at maximum instability. Our conclusion is that eddy covariance measurements can function well during stable conditions but that the functioning under strong instabilities might be a so far unforeseen problem.


2020 ◽  
Vol 42 ◽  
pp. e39
Author(s):  
Rubmara Ketzer Oliveira ◽  
Luciano Sobral Fraga Junior ◽  
Larissa Brêtas Moura ◽  
Debora Regina Roberti ◽  
Felipe Gustavo Pilau

Brazil is the main sugarcane producer in the world, which is intended for various purposes, from food to power generation. Soybean cultivation in areas of sugarcane under renewal has been growing progressively in Brazil. Quantifying energy fluxes at different stages of this process is essential for better management. The work was carried out in Piracicaba city, with the objective of analyzing the behavior of energy fluxes and the closing of the energy balance in a sugarcane renewal area with a fallow period followed by soybean cultivation. The latent and sensitive heat fluxes were obtained with the “Eddy covariance” method. The closing of the energy balance in the fallow period with straw-covered uncovered and soybean-cultivated soil presented a correlation coefficient of 0.88, 0.78 and 0.71, respectively. In the period without cultivation, the sensible heat flux was predominant in relation to the latent heat flux, varying according to the rainfall regime. The presence of straw under the soil in the fallow period affected the latent heat flux. With soybean cultivation, the latent heat flux surpassed the sensible heat flux.


2009 ◽  
Vol 6 (4) ◽  
pp. 8531-8567
Author(s):  
A. Lindroth ◽  
M. Mölder ◽  
F. Lagergren

Abstract. Temperature measurements in trunks and branches in a mature ca. 100 years-old mixed pine and spruce forest in central Sweden were used to estimate the heat storage in the tree biomass. The estimated heat flux in the sample trees and data on biomass distributions were used to scale up to stand level biomass heat fluxes. The rate of change of sensible and latent heat storage in the air layer below the level of the flux measurements was estimated from air temperature and humidity profile measurements and soil heat flux was estimated from heat flux plates and soil temperature measurements. The fluxes of sensible and latent heat from the forest were measured with an eddy covariance system in a tower. The analysis was made for a two-month period in summer of 1995. The tree biomass heat flux was the largest of the estimated storage components and varied between 40 and −35 W m−2 on summer days with nice weather. Averaged over two months the diurnal maximum of total heat storage was 45 W m−2 and the minimum was −35 W m−2. The soil heat flux and the sensible heat storage in air were out of phase with the biomass flux and they reached maximum values that were about 75% of the maximum of the tree biomass heat storage. The energy balance closure improved significantly when the total heat storage was added to the turbulent fluxes. The slope of a regression line with sum of fluxes and storage as independent and net radiation as dependent variable, increased from 0.86 to 0.95 for half-hourly data and the scatter was also reduced. The most significant finding was, however, that during nights with strongly stable conditions when the sensible heat flux dropped to nearly zero, the total storage matched the net radiation nearly perfectly. Another interesting result was that the mean energy imbalance started to increase when the Richardson number became more negative than ca. −0.1. In fact, the largest energy deficit occurred at maximum instability. Our conclusion is that eddy covariance measurements can function well during stable conditions but that the functioning under strong instabilities might be a so far unforeseen problem.


2020 ◽  
Vol 77 (9) ◽  
pp. 3211-3225
Author(s):  
Kristine F. Haualand ◽  
Thomas Spengler

Abstract The convoluted role of surface sensible and latent heat fluxes on moist baroclinic development demands a better understanding to disentangle their local and remote effects. Including diabatic effects in the Eady model, the direct effects of surface fluxes on the diabatic generation of eddy available potential energy as well as their indirect effects through modifications of the circulation and latent heating are investigated. It is shown that surface sensible heat fluxes have a minor impact, irrespective of their position and parameterization, while latent heating in the region equivalent to the warm conveyor belt is the dominant diabatic source for development. Downward surface sensible heat fluxes in proximity of the warm conveyor belt results in structural modifications that increase the conversion from basic-state available potential energy to eddy available potential energy, while concomitantly weakening the ascent and hence latent heating. The detrimental effects are easily compensated through provision of additional moisture into the warm conveyor belt. Upward surface heat fluxes in the cold sector, on the other hand, are detrimental to growth. When downward (upward) surface sensible heat fluxes are located below the equivalent of the warm conveyor belt, the diabatically induced PV anomaly at the bottom of the latent heating layer becomes dominant (less dominant). Shifting the downward surface sensible heat fluxes away from the warm conveyor belt results in substantial changes in the growth rate, latent heat release, low-level structure, and energetics, where the effect of surface sensible heat fluxes might even be beneficial.


Atmosphere ◽  
2019 ◽  
Vol 10 (6) ◽  
pp. 299
Author(s):  
Noman Ali Buttar ◽  
Hu Yongguang ◽  
Josef Tanny ◽  
M Waqar Akram ◽  
Abdul Shabbir

Precise estimation of surface-atmosphere exchange is a major challenge in micrometeorology. Previous literature presented the eddy covariance (EC) as the most reliable method for the measurements of such fluxes. Nevertheless, the EC technique is quite expensive and complex, hence other simpler methods are sought. One of these methods is Flux-Variance (FV). The FV method estimates sensible heat flux (H) using high frequency (~10Hz) air temperature measurements by a fine wire thermocouple. Additional measurements of net radiation (Rn) and soil heat flux (G) allow the derivation of latent heat flux (LE) as the residual of the energy balance equation. In this study, the Flux Variance method was investigated, and the results were compared against eddy covariance measurements. The specific goal of the present study was to assess the performance of the FV method for the estimation of surface fluxes along a variable fetch. Experiment was carried out in a tea garden; an EC system measured latent and sensible heat fluxes and five fine-wire thermocouples were installed towards the wind dominant direction at different distances (fetch) of TC1 = 170 m, TC2 = 165 m, TC3 = 160 m, TC4 = 155 m and TC5 = 150 m from the field edge. Footprint analysis was employed to examine the effect of temperature measurement position on the ratio between 90% footprint and measurement height. Results showed a good agreement between FV and EC measurements of sensible heat flux, with all regression coefficients (R2) larger than 0.6; the sensor at 170 m (TC1), nearest to the EC system, had highest R2 = 0.86 and lowest root mean square error (RMSE = 25 Wm−2). The estimation of LE at TC1 was also in best agreement with eddy covariance, with the highest R2 = 0.90. The FV similarity constant varied along the fetch within the range 2.2–2.4.


2020 ◽  
Author(s):  
Hai Bui ◽  
Thomas Spengler

<p class="p1"><span class="s1">The sea surface temperature (SST) distribution can modulate the development of extratropical cyclones through sensible and latent heat fluxes. However, the direct and indirect effects of these surface fluxes, and thus the SST, are still not well understood. This study tackles this problem using idealised channel simulations of moist baroclinic development under the influence of surface fluxes. The model is initialised with a zonal wind field resembling the midlatitude jet and a different SST distribution for each experiment, where both the strength and position of the SST gradient are varied.</span></p> <p class="p1"><span class="s1">The surface latent heat flux plays a key role in enhancing the moist baroclinic development, while the sensible heat fluxes play a minor and dampening role. The additional moisture provided by the latent heat fluxes originates from about 1000 km ahead of the cyclone a day prior to the time of the most rapid deepening. When the SST in this region is higher than 15 degrees Celsius, the additional latent heat is conducive to explosive cyclone development. A high absolute SST with a weak SST gradient, however, can lead to a delay of the deepening stage, because of unorganised convection at early stages. In addition, the cyclone can maintain its intensity for a longer period with an SST above 20 degrees Celsius, because there is a continuous and extensive moisture supply from the surface. The cyclone in this case has characteristics of a hybrid cyclone, where the latent heat release near the cyclone’s centre plays a major role in the development.</span></p>


Sign in / Sign up

Export Citation Format

Share Document