Nationwide investigation into adverse tissue reactions to metal debris after metal-on-metal total hip arthroplasty in Japan

2014 ◽  
Vol 19 (1) ◽  
pp. 85-89 ◽  
Author(s):  
Nobuhiko Sugano ◽  
Hirokazu Iida ◽  
Haruhiko Akiyama ◽  
Yoshio Takatori ◽  
Satoshi Nagoya ◽  
...  
2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Chih-Chien Hu ◽  
Tsan-Wen Huang ◽  
Shih-Jie Lin ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
...  

Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Peter Caspar Bünemann ◽  
Stefan Luck ◽  
Malte Ohlmeier ◽  
Thorsten Gehrke ◽  
Tobias Malte Ballhause

Osteoarthritis of the hip joint (coxarthrosis) is the most common hip disease in adults. Since the 1960s, total hip arthroplasty (THA) has made great progress and is nowadays one of the most frequently used procedures in orthopedic surgery. Different bearing concepts exist in various implant designs. A metal-on-metal bearing can create metal debris and lead to metallosis. We present a unique case of a 78-year old woman, who received hip resurfacing with a McMinn-like prosthesis 15 years ago. Over the cause of time, metallosis developed and created a bone cyst in the Os ilium, and osteolysis led to a dislocation of the femoral implant. A minor stumble fall led to a fracture of the Os ilium. We present our treatment method with implantation of a cemented THA and refill of the bone cyst with bone from allogene femoral heads. The surgery led to a reconstruction of the physiological center of rotation in the hip. Consequently, to the inpatient stay, the patient took part in a follow-up treatment with intensive physiotherapy. Taken together, the results after total hip arthroplasty are more superior to other hip surface replacements in terms of longevity and patient satisfaction. Especially, metal-on-metal bearing couples carry a great risk of metallosis, which goes a long with pseudotumors, osteolysis, and the elevated metal ions in the blood. Since this case is unique in the literature, no guidelines are noted for surgical treatment. In our opinion, a periprosthetic fracture of this type should be performed in a hospital using extensive endoprosthetic expertise.


2018 ◽  
Vol 52 (1) ◽  
pp. 26-30
Author(s):  
Jagandeep S Virk ◽  
Sudhir K Garg ◽  
Purnima Aggarwal ◽  
Reetu Kundu ◽  
Robin Bohat

ABSTRACT Second-generation metal-on-metal (MoM) total hip arthroplasty (THA) was introduced to overcome the complications associated with the wear debris from ultrahigh molecular weight polyethylene (UHMWPE). However, a new type of complication began appearing, described as aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Patients with ALVAL complain of pain and, in some cases, extensive swelling around the hip joint known as “pseudotumors.” The cause is unknown and probably multifactorial. This may be an adverse reaction to an excess of particulate metal wear debris or a hypersensitivity reaction to a normal amount of metal debris. Surgical findings are typical and symptoms tend to resolve reliably following conversion to an alternative bearing surface. We report one such case of a 55-year-old male, who underwent a revision of bearing surfaces because of ALVAL and pseudotumor formation following an MoM THA at our institute. How to cite this article Virk JS, Garg SK, Aggarwal P, Kundu R, Bohat R. Pseudotumor in Metal-on-metal Total Hip Arthroplasty: An Unusual Complication. J Postgrad Med Edu Res 2018;52(1):26-30.


2017 ◽  
Vol 106 (4) ◽  
pp. 342-349 ◽  
Author(s):  
H. Mäntymäki ◽  
M. Junnila ◽  
P. Lankinen ◽  
M. Seppänen ◽  
T. Vahlberg ◽  
...  

Background and Aims: An adverse reaction to metal debris is a known complication after large diameter head metal-on-metal total hip arthroplasty. However, the failure rate varies depending on the implant design. Therefore, we investigated the prevalence of adverse reaction to metal debris, as well as the symptoms and risk factors after undergoing a ReCap-M2a-Magnum large diameter head metal-on-metal total hip arthroplasty. Materials and Methods: Between 2005 and 2012, 1188 patients (1329 hips) underwent ReCap-M2a-Magnum total hip arthroplasty at our institution. Systematic screening for adverse reaction to metal debris was arranged using the Oxford Hip Score questionnaire, hip and pelvic radiographs, and assessments of the serum chromium and cobalt ion levels. Clinical evaluation and magnetic resonance imaging were performed for the symptomatic patients, as well as those with either chromium or cobalt ion levels ⩾5 µg/L. The prevalence of adverse reaction to metal debris after ReCap-M2a-Magnum total hip arthroplasty was assessed, and the risk factors for adverse reaction to metal debris were evaluated using logistic regression. The mean follow-up time was 5.2 (0.003–9.1) years. This study was an extension of a previous study conducted at our institution with 80 patients. Results: In total, 33 patients (33 hips, 2.5% of all hips) required a revision operation due to adverse reaction to metal debris. Moreover, 157 hips exhibited definitive adverse reaction to metal debris, but a revision operation was not performed (157 of 1329 hips, 11.8% of all hips). Overall, 190 out of 1329 (14.3%) hips had definitive adverse reaction to metal debris. Pain, subluxation sensation, clicking, swelling, a small head size, and a fair/poor Oxford Hip Score were associated with definitive adverse reaction to metal debris. Conclusion: We found a high prevalence of adverse reaction to metal debris in the ReCap-M2a-Magnum total hip arthroplasty patients in this study; however, most of the patients did not require revision operations.


2013 ◽  
Vol 84 (6) ◽  
pp. 549-554 ◽  
Author(s):  
Jari Mokka ◽  
Mika Junnila ◽  
Matti Seppänen ◽  
Petri Virolainen ◽  
Tuukka Pölönen ◽  
...  

2018 ◽  
Vol 28 (2_suppl) ◽  
pp. 35-42 ◽  
Author(s):  
Fabio D’Angelo ◽  
Davide Tanas ◽  
Enrico Gallazzi ◽  
Luigi Zagra

Introduction: Failures due to adverse reaction to metal debris (ARMD) have become an area of common focus among surgeons performing hip replacements. Several authors have reported data on the prevalence of these masses, in both symptomatic and asymptomatic patients after either large-diameter head metal-on-metal (MoM) total hip arthroplasty (THA) or hip resurfacing arthroplasty, with a large variability of rate. To our knowledge, few data are reported on the association of this lesion with the use of small-head diameter MoM. Methods: 15 hips that were revised for ARMD in small-head MoM THA were included in this study. We focused our attention on the difficulties of diagnosis and treatment and also on the histologic aspects of the harvested pathologic tissue. Results: The histological examination of our cases showed a presence of lymphocytic infiltrate suggesting a delayed hypersensitivity reaction to the metal of type IV (ALVAL), but different from each other in term of the prevalence of the cellular component. Osteolysis and severe soft tissue damage were also observed. Revision resulted in remission of the lesion and successful implant. Conclusions: Our observation suggests that the evidence of ARMD should be considered even in case of small-head MoM arthroplasty and therefore these patients should be followed scrupulously with 2nd level diagnostic tools such as magnetic resonance imaging with metal artifact reduction sequence (MARS-MRI) and metal ion levels at least once. Further investigations are necessary to establish the real prevalence of this phenomenon in the whole population of small-head MoM THAs.


Author(s):  
Lauren N Pearson ◽  
Robert L Schmidt ◽  
Kenneth Cahoon ◽  
Christopher E Pelt

Abstract Background Total nucleated cell (TNC) count and differential are used to classify joint effusions as inflammatory or noninflammatory. Further diagnostic evaluation and management is contingent on this classification. TNC count can be measured by automated analyzers or by manual assessment using a hemocytometer. Studies have raised concerns regarding the accuracy of TNC counts measured by automated instruments, particularly in the setting of joint arthroplasty. The objective of this study was to determine whether metallosis, a complication of total hip arthroplasty in which metal debris accumulates in periprosthetic tissues and synovial fluid, is associated with inaccurate TNC counts in synovial fluid. Methods We compared the accuracy of cell counts measured by the Sysmex XN-1000 and Beckman Coulter Iris iQ200 with the gold standard of manual assessment using a hemocytometer in synovial fluid from patients with suspected metallosis and in fluid obtained from controls from patients with native joints and a history of arthroplasty for other indications. Results TNC counts produced by automated analyzers were associated with increased levels of discordance (relative to manual counts) in patients with metallosis. Metallosis was not associated with increased levels of discordance for RBC counts or WBC differentials. The Sysmex XN flagged all but 1 metallosis sample for manual verification of the results. Conclusions Automated methods are generally reliable for analysis of synovial fluid. TNC counts can be inaccurate in the context of metallosis following total hip arthroplasty. Laboratories should correlate automated cell counts with a microscopic assessment of the specimen, as recommended by instrument manufacturers.


Sign in / Sign up

Export Citation Format

Share Document