Selection of palm oil mill effluent treatment for biogas generation or compost production using an analytic hierarchy process

2017 ◽  
Vol 20 (2) ◽  
pp. 787-799 ◽  
Author(s):  
Muhammad Ansori Nasution ◽  
Dhani S. Wibawa ◽  
Tofael Ahamed ◽  
Ryozo Noguchi
2017 ◽  
Vol 9 (1) ◽  
Author(s):  
Imam Setiadi ◽  
Dinda Rita K. Hartaja

Selection of the appropriate composition desalination units can be done with a variety of method approaches, one of the method is the Analytic Hierarchy Process. In determining the desalination unit with AHP method to consider is setting a goal, an alternative criteria and pairwise comparison. Research for the determination of the exact composition of the desalination unit in order to achieve sustainable drinking water suppy in coastal areas and small islands has been conducted. The results of the study are as follows, the energy demand of 50.83%, operator costs of 26.64%, maintenance costs of 14.13% and chemical requirement 8.4%. For an alternative composition desalination unit of RO 10 m3 / day is the best alternative composition with value of 59.61%, the composition of the next alternative is RO 20 m3/ day of 30.40% and the last alternative of the desalination unit composition is RO 120 m3/ day of 09.99%.Key words : Desalination, Mukti Stage Flash Composition, AHP


2016 ◽  
Vol 1 (1) ◽  
pp. 088
Author(s):  
Wahyu Joni Kurniawan

This study was conducted to assist in the selection of martial assistant coach, to determine who is right. Its results will didadaptkan by comparing the two methods in the decision support system, by using the Analytic Hierarchy Process (AHP) and the Simple Additive Weight (SAW) in limiting the problems in producing the desired solution, using multiple criteria (multi-criteria). AHP and SAW has a different way of doing the calculation. This is done to determine which method is looking for help in making decisions. And in this study are the criteria Discipline, Knowledge, Leadership, Attitude, and Level. And there are sub criteria on Level, which Black (AND I) and Red Black II.


2021 ◽  
Vol 294 ◽  
pp. 126295
Author(s):  
Ainil Farhan Mohd Udaiyappan ◽  
Hassimi Abu Hasan ◽  
Mohd Sobri Takriff ◽  
Siti Rozaimah Sheikh Abdullah ◽  
Nazlina Haiza Mohd Yasin ◽  
...  

2014 ◽  
Vol 54 (11) ◽  
pp. 3044-3053 ◽  
Author(s):  
M.A. Abdullah ◽  
M. Afzaal ◽  
Z. Ismail ◽  
A. Ahmad ◽  
M.S. Nazir ◽  
...  

2021 ◽  
Vol 411 ◽  
pp. 67-78
Author(s):  
Ivy Ai Wei Tan ◽  
J.R. Selvanathan ◽  
M.O. Abdullah ◽  
N. Abdul Wahab ◽  
D. Kanakaraju

Palm oil mill effluent (POME) discharged without treatment into watercourses can pollute the water source. Microbial fuel cell (MFC) has gained high attention as a green technology of converting organic wastewater into bio-energy. As an approach to overcome the limitations of the existing POME treatment methods, air-cathode MFC-Adsorption system is introduced as an innovative technology to treat POME and generate bio-electricity simultaneously. However, the use of conventional MFC with proton exchange membrane in large scale applications is restricted by the high cost and low power generation. Addition of mediator in MFC is essential in order to increase the electron transfer efficiency, hence enhancing the system performance. This study therefore aims to investigate the effect of different type of mediators i.e. congo red (CR), crystal violet (CV) and methylene blue (MB) on the performance of an affordable air-cathode MFC-Adsorption system made from earthen pot with POME as the substrate. The addition of different mediators altered the pH of the MFC-Adsorption system, in which more alkaline system showed better performance. The voltage generated in the system with CR, CV and MB mediator was 120.58 mV, 168.63 mV and 189.25 mV whereas the current generated was 2.41 mA, 3.37 mA and 3.79 mA, respectively. The power density of 290.79 mW/m3, 568.72 mW/m3 and 716.31 mW/m3 was produced in the MFC-Adsorption system with CR, CV and MB mediator, respectively. The highest POME treatment efficiency was achieved in MFC-Adsorption system with MB mediator, which resulted in biochemical oxygen demand, chemical oxygen demand, total suspended solids, turbidity and ammoniacal nitrogen removal of 75.3%, 84.8%, 91.5%, 86.1% and 23.31%, respectively. Overall, the air-cathode MFC-Adsorption system with addition of MB mediator was feasible for POME treatment and simultaneous bio-energy generation.


Sign in / Sign up

Export Citation Format

Share Document