The Effect of Thickness of the Dead Layer on the Magnetization of Ni0.5−xCoxZn0.5Fe2O4 Ferrite Nanopowders and Determination of Optimal Permeability

Author(s):  
F. Malakouti Khah ◽  
A. Arab ◽  
E. Kiani
Keyword(s):  
2017 ◽  
Vol 315 (1) ◽  
pp. 95-101 ◽  
Author(s):  
Truong Thi Hong Loan ◽  
Vu Ngoc Ba ◽  
Truong Huu Ngan Thy ◽  
Huynh Thi Yen Hong ◽  
Ngo Quang Huy

2000 ◽  
Vol 655 ◽  
Author(s):  
L. J. Sinnamon ◽  
R. M. Bowman ◽  
J. M. Gregg

AbstractThin film capacitors with barium strontium titanate (BST) dielectric layers of 7.5 to 950 nm were fabricated by Pulsed Laser Deposition. XRD and EDX analyses confirmed a strongly oriented BST cubic perovskite phase with the desired cation stoichiometry. Room temperature frequency dispersion (ε100 kHz / ε100 Hz) for all capacitors was greater than 0.75. Absolute values for the dielectric constant were slightly lower than expected. This was attributed to the use of Au top electrodes since the same sample showed up to a threefold increase in dielectric constant when Pt was used in place of Au. Dielectric constant as a function of thicknesses greater than 70 nm, was fitted using the series capacitor model. The large interfacial parameter ratio di / εi of 0.40 ± 0.05 nm implied a significant dead-layer component within the capacitor structure. Modelled consideration of the dielectric behaviour for BST films, whose total thickness was below that of the dead layer, predicted anomalies in the plots of d/ ε against d at the dead layer thickness. For the SRO/BST/Au system studied, no anomaly was observed. Therefore, either (i) 7.5 nm is an upper limit for the total dead layer thickness in this system, or (ii) dielectric collapse is not associated with a distinct interfacial dead layer, and is instead due to a through-film effect.


1994 ◽  
Vol 194-196 ◽  
pp. 619-620
Author(s):  
P.W. Adams ◽  
V. Pant ◽  
A.F. Hebard
Keyword(s):  

2019 ◽  
Vol 24 ◽  
pp. 174
Author(s):  
V. Angelopoulou ◽  
E. Kouvaris ◽  
V. Lagaki ◽  
T. J. Mertzimekis ◽  
P. Papagiannis

A decommissioned co-axial HPGe detector has been recently acquired and returned to operational mode in an effort to build an environmental radiation spectrometer at the University of Athens. The new counting station, GEROS (Germanium for Environmental RadiOactivity Studies), was fully characterized prior to operation to obtain detailed information on its linear response, efficiency and energy resolution. In addition to using point-like calibration sources (60Co,137Cs,152Eu and 226Ra), several bulk sample geometries were calibrated by means of an IAEA standard, focusing on soils, sediments and solid materials. In lieu of deteailed technical specifications, the crystal integrity, especially in regards to the dead layer known to build up over the years was studied by means of γ-ray tomography. The 3D geometry of the crystal was fully reconstructed considering the absorption coefficients, and the dead layer thickness was estimated. The overall crystal alignment inside the case was also checked. The results were verified by placing GEROS inside a medical CT scanner and irradiating it to obtain detailed longitudinal and transverse sections. The results were combined to provide input data for subsequent MCNP5 simulations. Good overall agreement between simulations and measurements was achieved. Despite some expected loss of resolution, the detector was found to perform substantially well.


Author(s):  
S.G. Ekhilevskiy ◽  
◽  
O.V. Golubeva ◽  
E.P. Potapenko ◽  
◽  
...  

At present, the main prospects for improving the insulating means of respiratory protection are associated with the chemical method of oxygen reservation. The arguments in favor of this choice are the high packing density of oxygen and its self-regulating supply, depending on the physical activity of a person. The main schemes of the air duct part of breathing apparatus on chemically bound oxygen are circular and pendulum. The attempt is made in the article to combine the advantages of the circular (small harmful space) and pendulum (small volume of the dead layer) schemes of breathing apparatus on chemically bound oxygen. For these purposes, the formalism method was developed, which allows mathematically and with the help of a computer to simulate the dynamic sorption activity of the regenerative cartridge of a breathing apparatus with a hybrid (circular-pendulum) scheme of the air duct part. The increase in the protective action of the apparatus is determined due to the use of the resource of the dead sorbent layer in the result of the air flow reverse in the pendulum part of the regenerative cartridge. Feasibility of using a hybrid scheme in the self-rescuers with a short period of protective action is shown. The optimal length of the pendulum part is determined, at which the breathing resistance decreases, and the harmful space occupied by the air returning for inhalation without contact with the unreacted layers of the oxygen-containing product is not increased. Its weak dependence on the total length of the regenerative cartridge and the maximum permissible concentration of carbon dioxide in the air returning to inhalation is shown, which makes the circular pendulum scheme realizable in practice.


Heliyon ◽  
2020 ◽  
Vol 6 (2) ◽  
pp. e03302
Author(s):  
Rinaldi Idroes ◽  
Muslem ◽  
Mahmudi ◽  
Saiful ◽  
Ghazi Mauer Idroes ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document