Development of a doctor blade printing method for fabrication of neutron activation foil arrays

2021 ◽  
Vol 330 (1) ◽  
pp. 385-394
Author(s):  
Jiseok Kim ◽  
Dong Jin Kim ◽  
Seung S. Lee
2016 ◽  
Vol 106 ◽  
pp. 05010
Author(s):  
Ben Volmert ◽  
Manuel Pantelias ◽  
R.K. Mutnuru ◽  
Erwin Neukaeter ◽  
Beat Bitterli

2016 ◽  
Author(s):  
Thomas Martin Miller ◽  
Cihangir Celik ◽  
Kimberly L. McMahan ◽  
Yi-kang Lee ◽  
Emmanuel Gagnier ◽  
...  

2010 ◽  
Vol 6 (2) ◽  
pp. 170-174
Author(s):  
Sunardi Sunardi ◽  
Muryono Muryono

Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec).  At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and  experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are  2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively.  The data  indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator.   Keywords: limit detection, AANC, neutron generator


2019 ◽  
Vol 23 ◽  
pp. 58
Author(s):  
I. E. Stamatelatos ◽  
T. Vasilopoulou ◽  
P. Batistoni ◽  
S. Conroy ◽  
B. Obryk ◽  
...  

In the present work, the preanalysis of activation foil experiments to determine neutron fluence rates along JET hall ducts and labyrinths is discussed. Simulations were performed using computational codes MCNPX and FISPACT-II and a detailed model of the JET hall, including the tokamak, biological shield and penetrations. The induced activity and detector count rate were predicted for activation foils placed at selected positions within the JET hall for Deuterium-Deuterium and Deuterium-Tritium JET plasma sources. The results of the calculations showed that satisfactory counting statistics can be obtained with the use of activation detectors and therefore activation analysis offers an unbiased and robust cross-benchmarking tool for comparison against other experimental and computation techniques applied in neutron streaming studies at JET.


2016 ◽  
Author(s):  
Thomas Martin Miller ◽  
Cihangir Celik ◽  
Kimberly McMahan Isbell ◽  
Yi-kang Lee ◽  
Emmanuel Gagnier ◽  
...  

Author(s):  
R. E. Heffelfinger ◽  
C. W. Melton ◽  
D. L. Kiefer ◽  
W. M. Henry ◽  
R. J. Thompson

A methodology has been developed and demonstrated which is capable of determining total amounts of asbestos fibers and fibrils in air ranging from as low as fractional nanograms per cubic meter (ng/m3) of air to several micrograms/m3. The method involves the collection of samples on an absolute filter and provides an unequivocal identification and quantification of the total asbestos contents including fibrils in the collected samples.The developed method depends on the trituration under controlled conditions to reduce the fibers to fibrils, separation of the asbestos fibrils from other collected air particulates (beneficiation), and the use of transmission microscopy for identification and quantification. Its validity has been tested by comparative analyses by neutron activation techniques. It can supply the data needed to set emissions criteria and to serve as a basis for assessing the potential hazard for asbestos pollution to the populace.


1963 ◽  
Vol 03 (02) ◽  
pp. 175-182 ◽  
Author(s):  
Bo Bergman ◽  
Rune Söremark

SummaryBy means of neutron activation and gamma-ray spectrometry the concentrations in the human mandibular articular disc of the following elements have been determined: Na, Mn, Cu, Zn, Rb, Sr, Cd, W, and Au. The discs were obtained at necropsy from seven men and nine women, ranging in age from 56 to 71 years.The activation was carried out in a thermal neutron flux of about 1.7 XlO12 neutrons × cm−2 × sec.−1 for about 20 hours. A chemical group separationwas performed before the gamma-ray spectrometry. Quantitative data based on the dry weight of the cartilage samples were obtained by comparing the photo-peak area of the identified elements with those of appropriate standards.


Sign in / Sign up

Export Citation Format

Share Document