scholarly journals Automated Pupillometry Identifies Absence of Intracranial Pressure Elevation in Intracerebral Hemorrhage Patients

Author(s):  
Antje Giede-Jeppe ◽  
Maximilian I. Sprügel ◽  
Hagen B. Huttner ◽  
Matthias Borutta ◽  
Joji B. Kuramatsu ◽  
...  

Abstract Introduction Although automated pupillometry is increasingly used in critical care settings, predictive value of automatically assessed pupillary parameters during different intracranial pressure (ICP) levels and possible clinical implications are unestablished. Methods This retrospective cohort study at the neurocritical care unit of the University of Erlangen-Nuremberg (2016–2018) included 23 nontraumatic supratentorial (intracerebral hemorrhage) ICH patients without signs of abnormal pupillary function by manual assessment, i.e., absent light reflex. We assessed ICP levels by an external ventricular drain simultaneously with parameters of pupillary reactivity [i.e., maximum and minimum apertures, light reflex latency (Lat), constriction and redilation velocities (CV, DV), and percentage change of apertures (per-change)] using a portable pupillometer (NeurOptics®). Computed tomography (CT) scans were analyzed to determine lesion location, size, intraventricular hemorrhage, hydrocephalus, midline shift, and compression or absence of the basal cisterns. We performed receiver operating characteristics analysis to investigate associations of ICP levels with pupillary parameters and to determine best cutoff values for prediction of ICP elevation. After dichotomization of assessments according to ICP values (normal: < 20 mmHg, elevated: ≥ 20 mmHg), prognostic performance of the determined cutoff parameters of pupillary function versus of CT-imaging findings was analyzed by calculating sensitivity, specificity, positive and negative predictive values (logistic regression, corresponding ORs with 95% CIs). Results In 23 patients (11 women, median age 59.0 (51.0–69.0) years), 1,934 assessments were available for analysis. A total of 74 ICP elevations ≥ 20 mmHg occurred in seven patients. Best discriminative thresholds for ICP elevation were: CV < 0.8 mm/s (AUC 0.740), per-change < 10% (AUC 0.743), DV < 0.2 mm/s (AUC 0.703), and Lat > 0.3 s (AUC 0.616). Positive predictive value of all four parameters to indicate ICP elevation ranged between 7.2 and 8.3% only and was similarly low for CT abnormalities (9.1%). We found high negative predictive values of pupillary parameters [CV: 99.2% (95% CI 98.3–99.6), per-change: 98.7% (95% CI 97.8–99.2), DV: 98.0% (95% CI 97.0–98.7), Lat: 97.0% (95% CI 96.0–97.7)], and CT abnormalities [99.7% (95% CI 99.2–99.9)], providing evidence that both techniques adequately identified ICH patients without ICP elevation. Conclusions Our data suggest an association between noninvasively detected changes in pupillary reactivity and ICP levels in sedated ICH patients. Although automated pupillometry and neuroimaging seem not sufficient to noninvasively indicate ICP elevation, both techniques, however, adequately identified ICH patients without ICP elevation. This finding may facilitate routine management by saving invasive ICP monitoring or repeated CT controls in patients with specific automated pupillometry readings.

2020 ◽  
pp. archdischild-2020-320549
Author(s):  
Fang Hu ◽  
Shuai-Jun Guo ◽  
Jian-Jun Lu ◽  
Ning-Xuan Hua ◽  
Yan-Yan Song ◽  
...  

BackgroundDiagnosis of congenital syphilis (CS) is not straightforward and can be challenging. This study aimed to evaluate the validity of an algorithm using timing of maternal antisyphilis treatment and titres of non-treponemal antibody as predictors of CS.MethodsConfirmed CS cases and those where CS was excluded were obtained from the Guangzhou Prevention of Mother-to-Child Transmission of syphilis programme between 2011 and 2019. We calculated sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) using receiver operating characteristics (ROC) in two situations: (1) receiving antisyphilis treatment or no-treatment during pregnancy and (2) initiating treatment before 28 gestational weeks (GWs), initiating after 28 GWs or receiving no treatment for syphilis seropositive women.ResultsAmong 1558 syphilis-exposed children, 39 had confirmed CS. Area under the curve, sensitivity and specificity of maternal non-treponemal titres before treatment and treatment during pregnancy were 0.80, 76.9%, 78.7% and 0.79, 69.2%, 88.7%, respectively, for children with CS. For the algorithm, ROC results showed that PPV and NPV for predicting CS were 37.3% and 96.4% (non-treponemal titres cut-off value 1:8 and no antisyphilis treatment), 9.4% and 100% (non-treponemal titres cut-off value 1:16 and treatment after 28 GWs), 4.2% and 99.5% (non-treponemal titres cut-off value 1:32 and treatment before 28 GWs), respectively.ConclusionsAn algorithm using maternal non-treponemal titres and timing of treatment during pregnancy could be an effective strategy to diagnose or rule out CS, especially when the rate of loss to follow-up is high or there are no straightforward diagnostic tools.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Diagnostics ◽  
2019 ◽  
Vol 9 (3) ◽  
pp. 109 ◽  
Author(s):  
Ukweh ◽  
Ugbem ◽  
Okeke ◽  
Ekpo

Background: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting. Materials and Methods: We surveyed fetal morphology ultrasound performed across five facilities and followed-up each fetus to ascertain the outcome. Fetuses were surveyed in the second trimester (18th–22nd weeks) using the International Society of Ultrasound in Obstetrics and Gynecology (ISUOG) guideline. Clinical and surgical reports were used as references to assess the diagnostic efficacy of ultrasound in livebirths, and autopsy reports to confirm anomalies in terminated pregnancies, spontaneous abortions, intrauterine fetal deaths, and still births. We calculated sensitivity, specificity, positive and negative predictive values, Area under the curve (AUC), Youden index, likelihood ratios, and post-test probabilities. Results: In total, 6520 fetuses of women aged 15–46 years (mean = 31.7 years) were surveyed. The overall sensitivity, specificity, and AUC were 77.1 (95% CI: 68–84.6), 99.5 (95% CI: 99.3–99.7), and 88.3 (95% CI: 83.7–92.2), respectively. Other performance metrics were: positive predictive value, 72.4 (95% CI: 64.7–79.0), negative predictive value, 99.6 (95% CI: 99.5–99.7), and Youden index (77.1%). Abnormality prevalence was 1.67% (95% CI: 1.37–2.01), and the positive and negative likelihood ratios were 254 (95% CI: 107.7–221.4) and 0.23 (95% CI: 0.16–0.33), respectively. The post-test probability for positive test was 72% (95% CI: 65–79). Conclusion: Fetal morphology assessment is valuable in a poor economics setting, however, the variation in the diagnostic efficacy across facilities and the limitations associated with the detection of circulatory system anomalies need to be addressed.


2021 ◽  
Vol 104 (3) ◽  
pp. 003685042110368
Author(s):  
Ananya Trongpisutsak ◽  
Vorapong Phupong

The objective was to determine whether a combination of serum micro RNA-210 level and uterine artery Doppler can predict preeclampsia in pregnant women at 16–24 weeks gestation. A prospective observational study conducted in singleton pregnant women at 16–24 weeks of gestation who had prenatal care at the King Chulalongkorn Memorial Hospital, Department of Obstetrics and Gynecology, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand between 2017 and 2018. Uterine artery Doppler ultrasound and blood testing for serum micro RNA-210 were performed. Pregnancy outcomes were recorded. Optimal cut-off for uterine artery pulsatility index (PI) and serum micro RNA-210 were obtained to calculate the predictive values for preeclampsia. Data from 443 participants were analyzed. Twenty-two cases developed preeclampsia (5.0%) and seven of these preeclamptic cases had early-onset preeclampsia (1.6%). Pregnant women with preeclampsia had higher mean PI of the uterine artery (1.34 ± 0.52 vs 0.98 ± 0.28, p = 0.004), higher detection rates of diastolic notching (45.5% vs 11.2%, p < 0.001), and lower median serum micro RNA-210 level (22.86 vs 795.78, p < 0.001) than pregnant women without preeclampsia. Using abnormal serum micro RNA-210 level, abnormal mean PI or uterine artery diastolic notches to predict for preeclampsia, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 95.5%, 54.9%, 10.0%, and 99.6%, respectively. For early-onset preeclampsia prediction, the sensitivity, specificity, PPV, and NPV were 100.0%, 53.2%, 3.3%, and 100.0%, respectively. This study demonstrated that a combination of serum micro RNA-210 and uterine artery Doppler is effective in predicting preeclampsia in the second trimester.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Konuralp Yakar

Aim. To compare the clinical performance of the Spot Vision Screener used to detect amblyopia risk factors (ARFs) in children before and after induction of cycloplegia; the children were referred because they met the screening criteria of the American Association for Pediatric Ophthalmology and Strabismus (AAPOS). Methods. The Spot Vision Screener and a standard autorefractometer were used to examine 200 eyes of 100 children aged 3–10 years, before and after cycloplegia induction, in terms of ARFs. Sensitivity, specificity, and positive and negative predictive values for the detection of significant refractive errors were measured using the AAPOS referral criteria. It was explored that Spot Screener data were affected by cycloplegia. The extent of agreement between cycloplegic/noncycloplegic photoscreening data and cycloplegic autorefraction measurements was assessed using Wilcoxon and Spearman correlation analyses. Results. The Spot’s sensitivity was improved from 60.9% to 85.3% and specificity from 94.9% to 87.4% with cycloplegia compared to cycloplegic standard autorefractometer results. The positive predictive value of Spot was 75.7%, and the negative predictive value was 90.4% without cycloplegia. With cycloplegia, the positive predictive value of Spot was 63.6% and the negative predictive value was 95.8%. Conclusions. The Spot Screener afforded moderate sensitivity and high specificity prior to cycloplegia. The sensitivity and negative predictive value improved after induction of cycloplegia. Examiners should be aware of the effects of cycloplegia on their findings.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Xiaohong Pu ◽  
Hongwei Zheng ◽  
Xin Yang ◽  
Qing Ye ◽  
Zhiwen Fan ◽  
...  

Abstract Background Using fluorescence in situ hybridisation (FISH) to detect any gain of chromosomes 3, 7, or 17 and loss of the 9p21 locus has been proven to be sensitive in the diagnosis of pancreatobiliary tumors. However, both genetic and environmental factors contribute to the pathogenesis of pancreatobiliary tumors. Therefore, it is unknown whether this method is suitable for Chinese patients with pancreatobiliary tumors. This study aims to compare the sensitivity, specificity, predictive values and accuracy of cytology, ERCP/MRCP and FISH based on Chinese patients with pancreatobiliary tumors,and to analyze differences between brushing-based and formalin-fixed paraffin-embedded (FFPE)-based FISH. Methods A total of 66 brush cytology specimens obtained during ERCP were detected by FISH and cytology test respectively to compare the sensitivity, specificity, predictive values and accuracy. Besides, FFPE-based FISH was performed on 46 corresponding paraffin sections of pancreatobiliary tumors obtained by surgical resection. Results Our findings demonstrate that FISH greatly improves diagnostic sensitivity and negative predictive value compared to ERCP/MRCP and cytology without much reduction in specificity and positive predictive value. However, our results also indicate that FFPE-based FISH could not effectively identify the false-negative of brushing-based FISH. Conclusions We believe that FISH can effectively distinguish true positive and false positive results of cytological or radiological suspicions of malignancy. However, FFPE-based FISH still does not precisely recognize the false-negative of brushing-based FISH. Both cytology-based and PPFE-based FISH had limitation in some specimens.


2018 ◽  
Vol 10 (3) ◽  
Author(s):  
Pokpong Piriyakhuntorn ◽  
Adisak Tantiworawit ◽  
Thanawat Rattanathammethee ◽  
Chatree Chai-Adisaksopha ◽  
Ekarat Rattarittamrong ◽  
...  

This study aims to find the cut-off value and diagnostic accuracy of the use of RDW as initial investigation in enabling the differentiation between IDA and NTDT patients. Patients with microcytic anemia were enrolled in the training set and used to plot a receiving operating characteristics (ROC) curve to obtain the cut-off value of RDW. A second set of patients were included in the validation set and used to analyze the diagnostic accuracy. We recruited 94 IDA and 64 NTDT patients into the training set. The area under the curve of the ROC in the training set was 0.803. The best cut-off value of RDW in the diagnosis of NTDT was 21.0% with a sensitivity and specificity of 81.3% and 55.3% respectively. In the validation set, there were 34 IDA and 58 NTDT patients using the cut-off value of >21.0% to validate. The sensitivity, specificity, positive predictive value and negative predictive value were 84.5%, 70.6%, 83.1% and 72.7% respectively. We can therefore conclude that RDW >21.0% is useful in differentiating between IDA and NTDT patients with high diagnostic accuracy


Rheumatology ◽  
2020 ◽  
Vol 60 (1) ◽  
pp. 239-249
Author(s):  
Sara Nysom Christiansen ◽  
Mikkel Østergaard ◽  
Ole Slot ◽  
Viktoria Fana ◽  
Lene Terslev

Abstract Objective To evaluate ultrasound for diagnosing gout using consensus-based Outcome Measures in Rheumatology ultrasound definitions of gout lesions. Methods Ultrasound was performed in patients with clinically suspected gout. Joints (28) and tendons (26) were binarily evaluated for the Outcome Measures in Rheumatology gout lesions—double contour (DC), tophus, aggregates and erosions. Ultrasound assessment was compared with two reference standards: (i) presence of MSU crystals in joint/tophus aspirate (primary outcome) and (ii) ACR/EULAR 2015 gout classification criteria (secondary outcome). Both reference standards were evaluated by rheumatologists blinded to ultrasound findings. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of each ultrasound lesion against both reference standards were determined. Results Eighty-two patients (70 men), mean age 62.4 (range 19–88) years, were included. Fifty-seven patients were MSU-positive whereas 25 patients were MSU-negative (no MSU crystals: 23; aspiration unsuccessful: 2). Of these 25 patients, three patients were classified as ACR/EULAR-positive (i.e. totally 60 ACR/EULAR-positive patients). All ultrasound lesions had high sensitivities for gout (0.77–0.95). DC and tophus showed high specificities (0.88–0.95), positive predictive values (0.94–0.98) and accuracies (0.82–0.84) when both reference standards were used. In contrast, low specificities were found for aggregates and erosions (0.32–0.59). Ultrasound of MTP joints for DC or tophus, knee joint for DC and peroneus tendons for tophus was sufficient to identify all MSU-positive patients with ultrasound signs of gout at any location. Conclusion Ultrasound-visualized DC and tophus, as defined by the Outcome Measures in Rheumatology ultrasound group, show high specificities, positive predictive values and accuracies for diagnosing gout and are therefore valid tools in clinical practice.


2017 ◽  
Vol 45 (4) ◽  
pp. 1347-1358 ◽  
Author(s):  
Chong Qi ◽  
Song Yang ◽  
Lanxi Meng ◽  
Huiyuan Chen ◽  
Zhenlan Li ◽  
...  

Purpose To evaluate the clinical utility of diffusion kurtosis tensor imaging in the characterization of cerebral glioma and investigate correlations between diffusion and kurtosis metrics with tumor cellularity. Materials and Methods A group of 163 patients (age: 40.5 ± 11.5 years) diagnosed with cerebral glioma underwent diffusion kurtosis tensor imaging with a 3 T scanner. Diffusion and kurtosis metrics were measured in the solid part of tumors, and their abilities to distinguish between tumor grades was evaluated. In addition, we analyzed correlations between the metrics and tumor cellularity. Results Mean kurtosis (MK) revealed a significant difference between each pair of tumor grades ( P < 0.05) and produced the best performance in a receiver operating characteristics analysis (area under the curve [AUC] = 0.89, sensitivity/specificity = 83.3/90). In contrast, mean diffusivity (MD) revealed a significant difference only for tumor grade II versus IV ( P < 0.05). No significant differences between grades were detected with fractional anisotropy (FA; P > 0.05). Thus, kurtosis metrics exhibited a positive and strong correlation with tumor cellularity, while MD exhibited a negative or weak correlation with tumor cellularity. Conclusion Diffusion kurtosis metrics, particularly MK, demonstrated superior performance in distinguishing cerebral glioma of different grades compared with conventional diffusion metrics, and were closely associated with tumor cellularity.


2017 ◽  
Vol 29 (11) ◽  
pp. 1763-1769 ◽  
Author(s):  
Pinar Soysal ◽  
Cansu Usarel ◽  
Gul Ispirli ◽  
Ahmet Turan Isik

ABSTRACTBackground:Comprehensive neurocognitive assessment may not be performed in clinical practice, as it takes too much time and requires special training. Development of easily applicable, time-saving, and cost effective screening methods has allowed identifying the individuals that require further evaluation. The aim of present study was to assess the diagnostic value of the Attended With (AW) and Head-Turning Sign (HTS) for screening cognitive impairment (CI).Methods:Comprehensive geriatric assessment was performed in 529 elderly outpatients, and the presence or absence of AW and HTS was investigated in them all.Results:Of the 529 patients, of whom the mean age was 75.67 ± 8.29 years, 126 patients were considered as CI (102 dementia, 24 mild CI). The patients with positive AW had significantly lower scores on Mini-Mental State Examination, Cognitive State Test, and Montreal Cognitive Assessment, and activities of daily living compared to AW (−) patients (p < 0.001). Similar significant findings were obtained in the patients with positive and negative HTS (p < 0.001). The sensitivity, specificity, positive predictive value, and negative predictive value of AW in detecting CI were 92%, 37%, 31.4%, and 93.7%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of HTS were 80%, 64%, 41.8%, and 91.5%, respectively. The area under the receiver-operating characteristics curve was 0.90 for AW and 0.82 for HTS.Conclusion:AW and HTS are fast, simple, effective, and sensitive methods for detecting CI. Therefore, they can be used for older adults attending the primary care settings with memory loss. Those with positive AW or HTS can be referred to the relevant centers for detailed cognitive assessment.


Sign in / Sign up