The results of 394 consecutive cases of knee joint radiation synovectomy (radiosynoviorthesis) using 90Y

2019 ◽  
Vol 34 (2) ◽  
pp. 94-101 ◽  
Author(s):  
Marcin Miszczyk ◽  
Bożena Jochymek ◽  
Leszek Miszczyk ◽  
Jacek Matysiakiewicz ◽  
Jerzy Spindel ◽  
...  
2006 ◽  
Vol 45 (01) ◽  
pp. 57-61
Author(s):  
M. Puille ◽  
D. Steiner ◽  
R. Bauer ◽  
R. Klett

Summary Aim: Multiple procedures for the quantification of activity leakage in radiation synovectomy of the knee joint have been described in the literature. We compared these procedures considering the real conditions of dispersion and absorption using a corpse phantom. Methods: We simulated different distributions of the activity in the knee joint and a different extra-articular spread into the inguinal lymph nodes. The activity was measured with a gammacamera. Activity leakage was calculated by measuring the retention in the knee joint only using an anterior view, using the geometric mean of anterior and posterior views, or using the sum of anterior and posterior views. The same procedures were used to quantify the activity leakage by measuring the activity spread into the inguinal lymph nodes. In addition, the influence of scattered rays was evaluated. Results: For several procedures we found an excellent association with the real activity leakage, shown by an r² between 0.97 and 0.98. When the real value of the leakage is needed, e. g. in dosimetric studies, simultaneously measuring of knee activity and activity in the inguinal lymph nodes in anterior and posterior views and calculation of the geometric mean with exclusion of the scatter rays was found to be the procedure of choice. Conclusion: When measuring of activity leakage is used for dosimetric calculations, the above-described procedure should be used. When the real value of the leakage is not necessary, e. g. for comparing different therapeutic modalities, several of the procedures can be considered as being equivalent.


2007 ◽  
Vol 27 (8) ◽  
pp. 729-734 ◽  
Author(s):  
Beata Chrapko ◽  
Robert Zwolak ◽  
Anna Nocuń ◽  
Renata Gołębiewska ◽  
Maria Majdan

Author(s):  
Martin Goetz ◽  
Stefan Klug ◽  
Kolja Gelse ◽  
Bernd Swoboda ◽  
Hans-Dieter Carl

2016 ◽  
Vol 15 (3) ◽  
pp. 206 ◽  
Author(s):  
BhagwantRai Mittal ◽  
Ashwani Sood ◽  
Aman Sharma ◽  
DevendraKumar Chouhan ◽  
Kirti Gupta ◽  
...  

1987 ◽  
Vol 16 (1) ◽  
pp. 121-129
Author(s):  
M. Möttönen ◽  
M. Pantio ◽  
T. Nevalainen

1993 ◽  
Vol 06 (02) ◽  
pp. 100-104 ◽  
Author(s):  
D. M. Pickles ◽  
C. R. Bellenger

SummaryTotal removal of a knee joint meniscus is followed by osteoarthritis in many mammalian species. Altered load-bearing has been observed in the human knee following meniscectomy but less is known about biochemical effects of meniscectomy in other species. Using pressure sensitive paper in sheep knee (stifle) joints it was found that, for comparable loads, the load-bearing area on the medial tibial condyle was significantly reduced following medial meniscectomy. Also, for loads of between 50 N and 500 N applied to the whole joint, the slope of the regression of contact area against load was much smaller. Following medial meniscectomy, the ability to increase contact area as load increased was markedly reduced.The load bearing area on the medial tibial condyle was reduced following meniscectomy.


1997 ◽  
Vol 36 (02) ◽  
pp. 71-75 ◽  
Author(s):  
S. Glatz ◽  
S. N. Reske ◽  
K. G. Grillenberger

Summary Aim: One therapeutic approach to rheumatoid arthritis and other inflammatory arthropathies besides surgical removal of inflamed synovium is radiation synovectomy using beta-emitting radionuclides to destroy the affected synovial tissue. Up to now the major problem associated with the use of labeled particles or colloids has been considerable leakage of radionuclides from the injected joint coupled with high radiation doses to liver and other non target organs. In this study we compared 188Re labeled hydroxyapatite particles and 188Re rhenium sulfur colloid for their potential use in radiation synovectomy. Methods: To this end we varied the labeling conditions (concentrations, pH-value, heating procedure) and analyzed the labeling yield, radiochemical purity, and in vitro stability of the resulting radiopharmaceutical. Results: After optimizing labeling conditions we achieved a labeling yield of more than 80% for 188Re hydroxyapatite and more than 90% for the rhenium sulfur colloid. Both of the radiopharmaceuticals can be prepared under aseptic conditions using an autoclav for heating without loss of activity. In vitro stability studies using various challenge solutions (water, normal saline, diluted synovial fluid) showed that 188Re labeled hydroxyapatite particles lost about 80% of their activity within 5 d in synovial fluid. Rhenium sulfur colloid on the other hand proved to be very stable with a remaining activity of more than 93% after 5 d in diluted synovial fluid. Conclusion: These in vitro results suggest that 188Re labeled rhenium sulfur colloid expects to be more suitable for therapeutic use in radiation synovectomy than the labeled hydroxyapatite particles.


Sign in / Sign up

Export Citation Format

Share Document