Detection of Legionella Species in Clinical Samples: Comparison of Polymerase Chain Reaction and Urinary Antigen Detection Kits

Infection ◽  
2006 ◽  
Vol 34 (5) ◽  
pp. 264-268 ◽  
Author(s):  
M. Koide ◽  
F. Higa ◽  
M. Tateyama ◽  
I. Nakasone ◽  
N. Yamane ◽  
...  
2014 ◽  
Vol 104 (3) ◽  
pp. 233-237 ◽  
Author(s):  
María José Iglesias Sánchez ◽  
Ana María Pérez Pico ◽  
Félix Marcos Tejedor ◽  
María Jesús Iglesias Sánchez ◽  
Raquel Mayordomo Acevedo

Background Dermatomycoses are a group of pathologic abnormalities frequently seen in clinical practice, and their prevalence has increased in recent decades. Diagnostic confirmation of mycotic infection in nails is essential because there are several pathologic conditions with similar clinical manifestations. The classical method for confirming the presence of fungus in nail is microbiological culture and the identification of morphological structures by microscopy. Methods We devised a nested polymerase chain reaction (PCR) that amplifies specific DNA sequences of dermatophyte fungus that is notably faster than the 3 to 4 weeks that the traditional procedure takes. We compared this new technique and the conventional plate culture method in 225 nail samples. The results were subjected to statistical analysis. Results We found concordance in 78.2% of the samples analyzed by the two methods and increased sensitivity when simultaneously using the two methods to analyze clinical samples. Now we can confirm the presence of dermatophyte fungus in most of the positive samples in just 24 hours, and we have to wait for the result of culture only in negative PCR cases. Conclusions Although this PCR cannot, at present, substitute for the traditional culture method in the detection of dermatophyte infection of the nails, it can be used as a complementary technique because its main advantage lies in the significant reduction of time used for diagnosis, in addition to higher sensitivity.


2020 ◽  
Vol 17 (1) ◽  
Author(s):  
Yang Zhang ◽  
Chunyang Dai ◽  
Huiyan Wang ◽  
Yong Gao ◽  
Tuantuan Li ◽  
...  

Abstract Background Coronavirus disease 2019 (COVID-19), caused by SARS-CoV-2, is posing a serious threat to global public health. Reverse transcriptase real-time quantitative polymerase chain reaction (qRT-PCR) is widely used as the gold standard for clinical detection of SARS-CoV-2. Due to technical limitations, the reported positive rates of qRT-PCR assay of throat swab samples vary from 30 to 60%. Therefore, the evaluation of alternative strategies to overcome the limitations of qRT-PCR is required. A previous study reported that one-step nested (OSN)-qRT-PCR revealed better suitability for detecting SARS-CoV-2. However, information on the analytical performance of OSN-qRT-PCR is insufficient. Method In this study, we aimed to analyze OSN-qRT-PCR by comparing it with droplet digital PCR (ddPCR) and qRT-PCR by using a dilution series of SARS-CoV-2 pseudoviral RNA and a quality assessment panel. The clinical performance of OSN-qRT-PCR was also validated and compared with ddPCR and qRT-PCR using specimens from COVID-19 patients. Result The limit of detection (copies/ml) of qRT-PCR, ddPCR, and OSN-qRT-PCR were 520.1 (95% CI: 363.23–1145.69) for ORF1ab and 528.1 (95% CI: 347.7–1248.7) for N, 401.8 (95% CI: 284.8–938.3) for ORF1ab and 336.8 (95% CI: 244.6–792.5) for N, and 194.74 (95% CI: 139.7–430.9) for ORF1ab and 189.1 (95% CI: 130.9–433.9) for N, respectively. Of the 34 clinical samples from COVID-19 patients, the positive rates of OSN-qRT-PCR, ddPCR, and qRT-PCR were 82.35% (28/34), 67.65% (23/34), and 58.82% (20/34), respectively. Conclusion In conclusion, the highly sensitive and specific OSN-qRT-PCR assay is superior to ddPCR and qRT-PCR assays, showing great potential as a technique for detection of SARS-CoV-2 in patients with low viral loads.


Author(s):  
Yogita Singh ◽  
Raji Vasanth ◽  
Shrikala Baliga ◽  
Dhanashree B

Objectives: Cultivation and identification of mycobacteria to species level remains difficult and time-consuming. Hence, easy and rapid diagnostic methods are necessary for the differentiation of Mycobacterium tuberculosis (MTB) from non-tuberculous mycobacteria (NTM). The present study aims to detect and differentiate MTB from NTM isolated from clinical samples by immunochromatographic test (ICT) and polymerase chain reaction (PCR). Methods: Over a period of 1 year, clinical samples (n=496) received from suspected cases of TB, at the Department of Microbiology, Kasturba Medical College Hospital, Mangalore were cultured to isolate Mycobacterium spp. Identification of all the isolates was done by conventional biochemical technique, ICT, and PCR. Results: Among the 496 samples processed, 49 (9.87%) were acid-fast bacilli smear positive and 59 (11.89%) samples showed the growth of Mycobacterium spp. Among these, 10 were rapid growers, 49 were slow-growing mycobacteria, out of which 30 were MTB as identified by conventional biochemical reaction. Out of 59 Mycobacterial isolates subjected to ICT for the detection of MPT 64 antigen, only 28 were identified as MTB. However, all the 30 isolates were correctly identified as MTB by PCR. Conclusion: Hence, PCR is essential for rapid differentiation of non-tuberculous Mycobacterium from MTB. False negative results seen with immunochromatographic MPT 64 antigen assay could be due to mutations within the mpt64 gene. Further studies are necessary to characterize these PCR-positive and immunochromatographic assay negative MTB isolates.


2010 ◽  
Vol 134 (3) ◽  
pp. 444-448 ◽  
Author(s):  
Zhengming Gu ◽  
Jianmin Pan ◽  
Matthew J. Bankowski ◽  
Randall T. Hayden

Abstract Context.—BK virus infections among immunocompromised patients are associated with disease of the kidney or urinary bladder. High viral loads, determined by quantitative polymerase chain reaction (PCR), have been correlated with clinical disease. Objective.—To develop and evaluate a novel method for real-time PCR detection and quantification of BK virus using labeled primers. Design.—Patient specimens (n = 54) included 17 plasma, 12 whole blood, and 25 urine samples. DNA was extracted using the MagNA Pure LC Total Nucleic Acid Isolation Kit (Roche Applied Science, Indianapolis, Indiana); sample eluate was PCR-amplified using the labeled primer PCR method. Results were compared with those of a user-developed quantitative real-time PCR method (fluorescence resonance energy transfer probe hybridization). Results.—Labeled primer PCR detected less than 10 copies per reaction and showed quantitative linearity from 101 to 107 copies per reaction. Analytical specificity of labeled primer PCR was 100%. With clinical samples, labeled primer PCR demonstrated a trend toward improved sensitivity compared with the reference method. Quantitative assay comparison showed an R2 value of 0.96 between the 2 assays. Conclusions.—Real-time PCR using labeled primers is highly sensitive and specific for the quantitative detection of BK virus from a variety of clinical specimens. These data demonstrate the applicability of labeled primer PCR for quantitative viral detection and offer a simplified method that removes the need for separate oligonucleotide probes.


Sign in / Sign up

Export Citation Format

Share Document