Residual load-bearing capacity of spannglass-beams: effect of post-tensioned reinforcement

2018 ◽  
Vol 4 (1) ◽  
pp. 83-97 ◽  
Author(s):  
Michael Engelmann ◽  
Bernhard Weller
2020 ◽  
Author(s):  
Antonino Recupero ◽  
Nino Spinella ◽  
Antonio Marì ◽  
Jesús Miguel Bairan

An experimental campaign on corroded post-tensioned concrete beams is being carried out at the University of Messina (Italy). The main goal of the research project is to study the influence of the tendon corrosion on the response behaviour of post-tensioned concrete beams subjected to a transversal load. In 2006, six beams were cast with a tendon placed at the centroid of the cross-section. Corrosion of the tendons was artificially induced in each specimen by injecting a chemical solution or an acid in some parts of the duct. The experimental results have showed how external causes, reproduced by artificial defects, can induce several critical issues, and undermine both the durability and the load bearing capacity of the beams. The load bearing capacity of the beam with defects was reduced until half of the one recorded for the specimen with not corroded tendon. In addition, a non-linear and time dependent analysis model, developed at UPC in Barcelona, was used to simulate the response of the tested beams, with the purpose of experimentally verifying the capacity of the model to capture the effects of corrosion along the time. A parametric study was performed with the numerical model to capture the influence of the degree of corrosion, (defined as the % loss of steel mass) on the serviceability response and on the ultimate capacity. By comparing the theoretical and the experimental results, the degree of corrosion was estimated and compared with that observed subsequently on the tested beams. Good correlation was obtained, thus allowing the numerical model to be used as a “virtual lab” to study the influence of several parameters on the structural response of corroded post-tensioned beams.


2016 ◽  
Vol 837 ◽  
pp. 38-43
Author(s):  
Ondrej Slowik ◽  
David Lehky ◽  
Martina Somodikova ◽  
Drahomir Novak

In the paper small-sample double-loop optimization method is employed to find selected design parameters of a single-span post-tensioned composite bridge to ensure its reliability and load-bearing capacity. The selected approach consists in nesting the computation of the failure probability with respect to the current design within the optimization loop. The analyzed bridge is made of precast post-tensioned concrete girders, each composed of six segments that are connected by the transverse joints. Bridge spatial deterioration brings uncertainty into actual values of concrete strength in transversal joints and of actual loss of pre-stressing. Due to their significant effect on the bridge load-bearing capacity, both were considered as uncertain design parameters with the aim to find their critical values corresponding to desired reliability level and load-bearing capacity.


2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


2021 ◽  
Vol 60 (1) ◽  
pp. 503-518
Author(s):  
Juan Han ◽  
Lu Zhu ◽  
Hai Fang ◽  
Jian Wang ◽  
Peng Wu

Abstract This article proposed an innovative composite sandwich structure reinforced with trapezoidal latticed webs with angles of 45°, 60° and 75°. Four specimens were conducted according to quasi-static compression methods to investigate the compressive behavior of the novel composite structures. The experimental results indicated that the specimen with 45° trapezoidal latticed webs showed the most excellent energy absorption ability, which was about 2.5 times of the structures with vertical latticed webs. Compared to the traditional composite sandwich structure, the elastic displacement and ultimate load-bearing capacity of the specimen with 45° trapezoidal latticed webs were increased by 624.1 and 439.8%, respectively. Numerical analysis of the composite sandwich structures was carried out by using a nonlinear explicit finite element (FE) software ANSYS/LS-DYNA. The influence of the thickness of face sheets, lattice webs and foam density on the elastic ultimate load-bearing capacity, the elastic displacement and initial stiffness was analyzed. This innovative composite bumper device for bridge pier protection against ship collision was simulated to verify its performance. The results showed that the peak impact force of the composite anti-collision device with 45° trapezoidal latticed webs would be reduced by 17.3%, and the time duration will be prolonged by about 31.1%.


Friction ◽  
2021 ◽  
Author(s):  
Luyao Gao ◽  
Xiaoduo Zhao ◽  
Shuanhong Ma ◽  
Zhengfeng Ma ◽  
Meirong Cai ◽  
...  

AbstractSilicone elastomers-based materials have been extensively involved in the field of biomedical devices, while their use is extremely restricted due to the poor surface lubricity and inherent hydrophobicity. This paper describes a novel strategy for generating a robust layered soft matter lubrication coating on the surface of the polydimethylsiloxane (PDMS) silicone elastomer, by entangling thick polyzwitterionic polyelectrolyte brush of poly (sulfobetaine methacrylate) (PSBMA) into the sub-surface of the initiator-embedded stiff hydrogel coating layer of P(AAm-co-AA-co-HEMA-Br)/Fe, to achieve a unified low friction and high load-bearing properties. Meanwhile, the stiff hydrogel layer with controllable thickness is covalently anchored on the surface of PDMS by adding iron powder to provide catalytic sites through surface catalytically initiated radical polymerization (SCIRP) method and provides high load-bearing capacity, while the topmost brush/hydrogel composite layer is highly effective for aqueous lubrication. Their synergy effects are capable of attaining low friction coefficient (COFs) under wide range of loaded condition in water environment with steel ball as sliding pair. Furthermore, the influence of mechanical modulus of the stiff hydrogel layer on the lubrication performance of layered coating is investigated, for which the COF is the lowest only when the modulus of the stiff hydrogel layer well matches the PDMS substrate. Surprisingly, the COF of the modified PDMS could remain low friction (COF < 0.05) stably after encountering 50,000 sliding cycles under 10 N load. Finally, the surface wear characterizations prove the robustness of the layered lubricating coating. This work provides a new route for engineering lubricious silicon elastomer with low friction, high load-bearing capacity, and considerable durability.


Sign in / Sign up

Export Citation Format

Share Document