scholarly journals The effects of ejector adiabatic absorber on heat and mass transfer of binary nanofluid with heat transfer additives

Author(s):  
Umar Aliyu Muhammad ◽  
Debabratta Bhattacharyya ◽  
Jose Louis Endrino ◽  
Sonia Fereres

AbstractThis paper presents experimental results on the study of the effects of ejector adiabatic absorber on heat and mass transfer of binary nanofluid with heat transfer additives (2-ethyl-1-hexanol and gum Arabic). In this case, H2O/lithium bromide-alumina nanofluid was suggested due to a growing interest in absorption heat transfer working fluid for solar energy application. An experimental setup — ejector test rig — was designed to study the absorption, heat, and mass transfer rate as a result of refrigerant vapour mass flow entrained by the ejector adiabatic absorber. The study was carried out at different solution mass flowrate (0.051 to 0.17 kg/s) with three prepared sample solutions, which include pure LiBr solution, LiBr-Alumina nanofluid without heat transfer additives, and LiBr-Alumina nanofluid with heat transfer additives. The absorption rate, mass transfer coefficient, heat transfer rate, and heat transfer coefficient for the three samples were reported. On the other hand, the percentage enhancements for all the parameters — at a suitable flow rate of 0.085 kg/s — due to the addition of alumina without and with heat transfer additives were recorded. The absorption rate enhancements were 25% and 96%, the enhancement rates of mass transfer coefficient recorded were 20% and 82%, the heat transfer rate enhancements were 85% and 183%, and the heat transfer coefficient enhancements obtained were 72% and 156% with addition of alumina nanoparticles only and alumina nanoparticles with heat transfer additives respectively. Material mass balance analysis suggests that mass inflow in the ejector equals to the mass outflow from the ejector, indicating a complete absorption of the entrained refrigerant vapour beyond which falling film absorption can occur due to concentration. This article also presents experimental evidence of the capability of ejector as strong adiabatic absorber, heat, and mass transfer component, which were earlier reported using numerical models.

2012 ◽  
Vol 204-208 ◽  
pp. 4305-4314
Author(s):  
Jing Jing Zhang ◽  
Dan Dan Zhao ◽  
Lu Chun Wan ◽  
Bao Huai Zhang ◽  
Ya Ping Chen

A mathematical model of heat and mass transfer process in plate falling film absorber with wire-meshed fins was developed. The model could predict temperature and concentration distribution as well as the solution side heat transfer coefficient and the absorption rate. The results verify that heat and mass transfer performance of the plate falling film absorber with wire-meshed fins is better than the past absorber. Compared with the plate falling film absorber without fins, heat transfer coefficient of the absorber in this article increases 1.06 times and the absorption rate increases 2.32 times.


Author(s):  
Gligor H. Kanevce ◽  
Ljubica P. Kanevce ◽  
George S. Dulikravich ◽  
Marcelo J. Colac¸o

The inverse problem of using temperature measurements to estimate the moisture content and temperature-dependent moisture diffusivity together with the heat and mass transfer coefficients is analyzed in this paper. In the convective drying practice, usually the mass transfer Biot number is very high and the heat transfer Biot number is very small. This leads to a very small temperature sensitivity coefficient with respect to the mass transfer coefficient when compared to the temperature sensitivity coefficient with respect to the heat transfer coefficient. Under these conditions the relative error of the estimated mass transfer coefficient is high. To overcome this problem, in this paper the mass transfer coefficient is related to the heat transfer coefficient through the analogy between the heat and mass transfer processes in the boundary layer. The resulting parameter estimation problem is then solved by using a hybrid constrained optimization algorithm OPTRAN.


2019 ◽  
Vol 141 (6) ◽  
Author(s):  
David A. Aderibigbe

The paper reviews the present understanding of the analysis of the heat and mass transfer processes in single-slope solar stills. By using the results of published experiments, it is proposed that the heat and mass transfer phenomena from the basin water to the glass cover are coupled. This coupling makes it possible to derive the dependence of the heat transfer coefficient for condensation on the inclination of the glass cover of the still. The derived relation, i.e., Nucon = 0.738 (Grcon*Prcon*sin β/Ja*)¼ A−1 where A is the aspect ratio, has been demonstrated to be an important expression for predicting the heat transfer coefficient for condensation hcon necessary for a more realistic evaluation of the overall efficiency of single-slope solar still of a given cover angle β.


2020 ◽  
Vol 194 ◽  
pp. 01027
Author(s):  
Shibo Zhao ◽  
Yonghui Zhang ◽  
Yunqi Nie ◽  
Pengyu Qu ◽  
Wenqiang Sun

The traditional refrigeration method of internet data center (IDC) is mostly air refrigeration, which has undesired cooling effect and high power consumption. This study addresses this problem and proposes an evaporative air cooler (EAC) suitable for IDC. Given the high specific heat capacity of water, the evaporative condensing coil and spray device are added to the evaporative cooler to enhance the heat transfer effect. Heat and mass transfer mathematical models are established to analyze the heat transfer performance. The mathematical model is used to simulate the profile of the heat and mass transfer coefficient of the EAC with the amount of spray water and air flow. The results show that when the air flow changes from 10 to 20 kg/s, the air equivalent heat transfer coefficient increases by about 41%. When the air flow rate is 20 kg/s and the spray water volume is 0.00124 kg/(mꞏs), the total heat transfer coefficient is increased by about 308% compared with the case without spray water.


2019 ◽  
Vol 23 (1) ◽  
pp. 331-345 ◽  
Author(s):  
Raheel Ahmed ◽  
Nasir Ali ◽  
Khurram Javid

In the present study heat and mass transfer phenomena in flow of non-Newtonian Sisko fluid induced by peristaltic activity through a curved channel have been investigated numerically using an implicit finite difference scheme. The governing equations are formulated in terms of curvilinear co-ordinates with appropriate boundary conditions. Numerically solution is carried out under long wavelength and low Reynolds number assumptions. The velocity field, pressure rise per wavelength, stream function, temperature, and concentration fields have been analyzed for the effects of curvature parameter, viscosity parameter, and power law index. Additionally, the computation for heat transfer coefficient and Sherwood number carried out for selected thermophysical parameters. The main results that are extracted out this study is that for strong shear-thinning biofluids (power-law rheological index, n < 1) the flow exhibits the boundary-layer character near the boundary walls. Both temperature and mass concentration are found to increase with increasing the generalized ratio of infinite shear rate viscosity to the consistency index. The amplitude of heat transfer coefficient and Sherwood number is also an increasing function of generalized ratio of infinite shear rate viscosity to the consistency index.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Mapula Lucey Moropeng ◽  
Andrei Kolesnikov ◽  
Mykhaylo Lototskyy ◽  
Avhafunani Mavhungu

AbstractThis paper presents the investigation of a two dimensional coupled model of heat and mass transfer in a mixture of AB2 – AB5 metal hydride (MH) systems of a cylindrical configuration during hydrogen sorption using COMSOL 5.3a commercial software. The parametric study on the sorption process has been studied with variation of heat transfer coefficient (HTC), and activation energy (AE) to understand the effects they have on the reaction kinetics of the sorption process. The simulation results demonstrate the importance of mutual dependence between the temperature propagation in the body of metal hydride, the absorbed concentration of the hydrogen gas, and the gas pressure for the absorption of hydrogen gas in metal hydrides. The decrease in the activation energy is found to have significant effect on the dynamic performances of hydrogen absorption in the MH reactors with an increased amount of hydrogen conversion, whilst the variation of heat transfer coefficient displayed insignificant change in hydrogen conversion. The simulated results show good agreement with the experimental results obtained from HYSA Systems and were implemented for use in the STILL RX60-30L electric forklift fuel cell applications designed by HYSA Systems in the University of the Western Cape.


2021 ◽  
Vol 25 (1) ◽  
pp. 53-65
Author(s):  
N. P. Grigorova ◽  
P. V. Monastyrev ◽  
E. G. Pakhomova ◽  
N. Ye. Semicheva

Purpose of research. is to investigate the degree of augmentation of the mass transfer coefficient of a heat transfer medium in contact with a "spot" of liquid on the surface of the vortex blade when it is bombarded with dispersed contaminants in a vortex heat exchanger in order to identify a pattern that allows obtaining design values of the heat transfer coefficient of the heat transfer medium that have the best agreement with the experimental values provided in previously published articles [4, 6, 7].Methods. A complex analysis of the degree of augmentation of the mass transfer coefficient of the heat transfer medium on the surface of the vortex blade in a vortex heat exchanger based on the known theoretical positions and equations of heat and mass transfer processes.Results. The dependence of the augmentation of the mass transfer coefficient of the heat transfer medium in contact with the "spot" of liquid on the surface of the vortex blade when it is bombarded with dispersed contaminants was obtained, which allows obtaining the best agreement of the design and experimental values of the heat transfer coefficient in the vortex heat exchanger of a gas pressure regulating and metering station.Conclusion. The values of the heat transfer coefficient of the heat transfer medium calculated using the obtained dependence of the augmentation of the mass transfer coefficient of the heat transfer medium have a satisfactory convergence with the experimental data, which allows us to use this dependence in engineering calculations of the design parameters of the vortex heat exchanger used as a heat exchanger for the heating system of the working area of the gas pressure regulating and metering station. This technical solution allows not only saving natural gas as a source of heat generation, but also reducing the negative impact on the environment, since there is no need to burn natural gas. In this case, the production of thermal energy is carried out due to a regulated pressure drop of natural gas coming from the main line to consumers.


2021 ◽  
Vol 45 (03) ◽  
Author(s):  
NGUYEN HIEU NGHIA ◽  
LE CHI HIEP ◽  
DUONG CONG TRUYEN

The absorption process has been confirmed as the most important process in absorption refrigeration machines in terms of improving their total efficiency. One of the key research directions is the selection of absorber structure which is expected to be fabricated in Vietnam without demand of new infrastructure investment. In this study, a local model of the coupled heat and mass transfer during absorption process of NH3 vapor by a NH3-H2O diluted solution flowing over horizontal round tubes of an absorber was made. The heat transfer coefficient obtained from the coupled heat and mass transfer mathematic model. This heat transfer coefficient is used to calculate the variation of the simulated value of heat load. The correlations which give the heat transfer coefficient and mass transfer coefficient in the absorption process in range of solution concentration ω = 28% ÷ 31%, solution mass flow rate per unit tube length Γ = 0.001 ÷ 0.03 kgm-1s-1, coolant temperature twater = 28 oC ÷ 38 oC are set as two functions. The practical decrease of wetted ratio analyses were taken into account when the solution flow from the top to the bottom of the parallel tube bundle. The deviation of theoretical heat load and experimental heat load is about 12.3%. Based on these simulations, the theoretical studies were done for absorption refrigeration system in order to narrow the working area where the experiments later focused on. The results of this study will be the basis for subsequent application research of falling film absorbers.