Coal Usage and Control of CO2 Emissions

Author(s):  
Dilip Kumar ◽  
Deepak Kumar
Keyword(s):  
Sensors ◽  
2019 ◽  
Vol 19 (13) ◽  
pp. 2901 ◽  
Author(s):  
Hossain ◽  
Georges ◽  
Rondeau ◽  
Divoux

There are all sort of indications that Internet usage will go only upwards, resulting in an increase in energy consumption and CO2 emissions. At the same time, a significant amount of this carbon footprint corresponds to the information and communication technologies (ICT) sector, with around one third being due to networking. In this paper we have approached the problem of green networking from the point of view of sustainability. Here, alongside energy-aware routing, we have also introduced pollution-aware routing with environmental metrics like carbon emission factor and non-renewable energy usage percentage. We have proposed an algorithm based on these three candidate-metrics. Our algorithm provides optimum data and control planes for three different metrics which regulate the usage of different routers and adapt the bandwidth of the links while giving the traffic demand requirements utmost priority. We have made a comparison between these three metrics in order to show their impact on greening routing. The results show that for a particular scenario, our pollution-aware routing algorithm can reduce 36% and 20% of CO2 emissions compared to shortest path first and energy-based solutions, respectively.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1212 ◽  
Author(s):  
Yao Qian ◽  
Lang Sun ◽  
Quanyi Qiu ◽  
Lina Tang ◽  
Xiaoqi Shang ◽  
...  

Decomposing main drivers of CO2 emissions and predicting the trend of it are the key to promoting low-carbon development for coping with climate change based on controlling GHG emissions. Here, we decomposed six drivers of CO2 emissions in Changxing County using the Logarithmic Mean Divisia Index (LMDI) method. We then constructed a model for CO2 emissions prediction based on a revised version of the Stochastic Impacts by Regression on Population, Affluence, and Technology (STIRPAT) model and used it to simulate energy-related CO2 emissions in five scenarios. Results show that: (1) From 2010 to 2017, the economic output effect was a significant, direct, dominant, and long-term driver of increasing CO2 emissions; (2) The STIRPAT model predicted that energy structure will be the decisive factor restricting total CO2 emissions from 2018 to 2035; (3) Low-carbon development in the electric power sector is the best strategy for Changxing to achieve low-carbon development. Under the tested scenarios, Changxing will likely reach peak total CO2 emissions (17.95 million tons) by 2030. Measures focused on optimizing the overall industrial structure, adjusting the internal industry sector, and optimizing the energy structure can help industry-oriented counties achieve targeted carbon reduction and control, while simultaneously achieving rapid economic development.


Author(s):  
Whitney G. Colella

We evaluate innovative design, installation, and control strategies for generating combined cooling, heating, and electric power (CCHP) with fuel cell systems (FCS). The addition of an absorptive cooling cycle allows unrecovered FCS heat to be converted into cooling power, such as for air-conditioning. For example, unrecovered low temperature (80–160°C) heat can be used to drive absorption chillers to create a chilled water stream to cool building spaces. Compared with separate devices that individually generate electricity, heat, and cooling power, such CCHP FCS can reduce feedstock fuel consumption and the resulting greenhouse gas emissions (GHG) by at least 30%. We develop economic and environmental models that optimize the installed capacity of CCHP FCS to minimize either global carbon dioxide (CO2) emissions or global energy costs. Our models evaluate innovative engineering design, installation, and control strategies not commonly pursued by industry, and identify strategies most beneficial for reducing CO2 emissions or costs. Our models minimize costs for building owners consuming cooling power, electricity, and heat by changing the installed capacity of the FCS and by changing FCS operating strategies. Our models optimize for a particular location, climatic region, building load curve set, FCS type, and competitive environment. Our models evaluate the benefits and drawbacks of pursuing more innovative FCS operating strategies; these include 1) connecting FCS to distribution networks for cooling power, heat, and electricity; 2) implementing a variable heat-to-power ratio, to intentionally produce additional heat to meet higher heat demands; 3) designing in the ability to tune the quantity of cooling power from the absorption chiller compared with the amount of recoverable heat from the FCS; and 4) employing the ability to load-follow demand for cooling, heat, or electricity. We base our datum design conditions on measured data describing generator performance in-use, and on measured data describing real-time electricity, heating, and cooling demand over time. A unique feature of our data sets is that the space cooling demand is directly measured and distinguishable from electricity demand (unlike as with standard air conditioning systems). We report results for optimal installed capacities and optimal FCS operating strategies. We generalize these results so that they are applicable to a wide-range of environments throughout the world.


Author(s):  
R. R. Dils ◽  
P. S. Follansbee

Electric fields have been applied across oxides growing on a high temperature alloy and control of the oxidation of the material has been demonstrated. At present, three-fold increases in the oxidation rate have been measured in accelerating fields and the oxidation process has been completely stopped in a retarding field.The experiments have been conducted with an iron-base alloy, Pe 25Cr 5A1 0.1Y, although, in principle, any alloy capable of forming an adherent aluminum oxide layer during oxidation can be used. A specimen is polished and oxidized to produce a thin, uniform insulating layer on one surface. Three platinum electrodes are sputtered on the oxide surface and the specimen is reoxidized.


Author(s):  
D. M. DePace

The majority of blood vessels in the superior cervical ganglion possess a continuous endothelium with tight junctions. These same features have been associated with the blood brain barrier of the central nervous system and peripheral nerves. These vessels may perform a barrier function between the capillary circulation and the superior cervical ganglion. The permeability of the blood vessels in the superior cervical ganglion of the rat was tested by intravenous injection of horseradish peroxidase (HRP). Three experimental groups of four animals each were given intravenous HRP (Sigma Type II) in a dosage of.08 to.15 mg/gm body weight in.5 ml of.85% saline. The animals were sacrificed at five, ten or 15 minutes following administration of the tracer. Superior cervical ganglia were quickly removed and fixed by immersion in 2.5% glutaraldehyde in Sorenson's.1M phosphate buffer, pH 7.4. Three control animals received,5ml of saline without HRP. These were sacrificed on the same time schedule. Tissues from experimental and control animals were reacted for peroxidase activity and then processed for routine transmission electron microscopy.


Author(s):  
G. Mazzocchi ◽  
P. Rebuffat ◽  
C. Robba ◽  
P. Vassanelli ◽  
G. G. Nussdorfer

It is well known that the rat adrenal zona glomerulosa steroidogenic activity is controlled by the renin-angiotensin system. The ultrastructural changes in the rat zona glomerulosa cells induced by renovascular hypertension were described previously, but as far as we are aware no correlated biochemical and morphometric investigations were performed.Twenty adult male albino rats were divided into 2 experimental groups. One group was subjected to restriction of blood flow to the left kidney by the application of a silver clip about the left renal artery. The other group was sham-operated and served as a control. Renovascular hypertension developed in about 10 days: sistolic blood pressure averaged 165 ± 6. 4 mmHg, whereas it was about 110 ± 3. 8 mmHg in the control animals. The hypertensive and control rats were sacrificed 20 days after the operation. The blood was collected and plasma renin activity was determined by radioimmunological methods. The aldosterone concentration was radioimmunologically assayed both in the plasma and in the homogenate of the left capsular adrenal gland.


Author(s):  
Henry I. Smith ◽  
D.C. Flanders

Scanning electron beam lithography has been used for a number of years to write submicrometer linewidth patterns in radiation sensitive films (resist films) on substrates. On semi-infinite substrates, electron backscattering severely limits the exposure latitude and control of cross-sectional profile for patterns having fundamental spatial frequencies below about 4000 Å(l),Recently, STEM'S have been used to write patterns with linewidths below 100 Å. To avoid the detrimental effects of electron backscattering however, the substrates had to be carbon foils about 100 Å thick (2,3). X-ray lithography using the very soft radiation in the range 10 - 50 Å avoids the problem of backscattering and thus permits one to replicate on semi-infinite substrates patterns with linewidths of the order of 1000 Å and less, and in addition provides means for controlling cross-sectional profiles. X-radiation in the range 4-10 Å on the other hand is appropriate for replicating patterns in the linewidth range above about 3000 Å, and thus is most appropriate for microelectronic applications (4 - 6).


Sign in / Sign up

Export Citation Format

Share Document