cooling power
Recently Published Documents


TOTAL DOCUMENTS

598
(FIVE YEARS 221)

H-INDEX

28
(FIVE YEARS 6)

2022 ◽  
Vol 3 (1) ◽  
pp. 20-36
Author(s):  
Bruno Costa Feijó ◽  
◽  
Ana Pavlovic ◽  
Luiz Alberto Oliveira Rocha ◽  
Liércio André Isoldi ◽  
...  

Microchannels are important devices to improve the heat exchange in several engineering applications as heat, ventilation and air conditioning, microelectronic cooling, power generation systems and others. The present work performs a numerical study of a microchannel with two trapezoidal blocks subjected to laminar flows, aiming to analyze the influence of the boiling process on the geometric configuration of the microchannel. Constructal Design and Exhaustive Search are used for the geometrical evaluation of the blocks. The Mixture multi-phase model and the Lee phase change model were both employed for the numerical simulation of the boiling process. In this study, the influence of the height and higher width of the first block (H11/L11) over the heat transfer rate and pressure drop for different magnitudes of the ratio between the lower width and higher width (L12/L11) was investigated. It is considered water in monophase cases and water/vapor mixture for multiphase flow. Two different Reynolds numbers (ReH = 0.1 and 10.0) were investigated. Results indicated that, for the present thermal conditions, the consideration of boiling flows were not significant for prediction of optimal configurations. Results also showed that in the cases where the boiling process was enabled, the multi-objective performance was higher than in the cases without boiling, especially for ReH = 0.1.


2022 ◽  
Vol 6 (1) ◽  
pp. 1-28
Author(s):  
Rongrong Wang ◽  
Duc Van Le ◽  
Rui Tan ◽  
Yew-Wah Wong

At present, a co-location data center often applies an identical and low temperature setpoint for its all server rooms. Although increasing the temperature setpoint is a rule-of-thumb approach to reducing the cooling energy usage, the tenants may have different mentalities and technical constraints in accepting higher temperature setpoints. Thus, supporting distinct temperature setpoints is desirable for a co-location data center in pursuing higher energy efficiency. This calls for a new cooling power attribution scheme to address the inter-room heat transfers that can be up to 9% of server load as shown in our real experiments. This article describes our approaches to estimating the inter-room heat transfers, using the estimates to rectify the metered power usages of the rooms’ air handling units, and fairly attributing the power usage of the shared cooling infrastructure (i.e., chiller and cooling tower) to server rooms by following the Shapley value principle. Extensive numeric experiments based on a widely accepted cooling system model are conducted to evaluate the effectiveness of the proposed cooling power attribution scheme. A case study suggests that the proposed scheme incentivizes rational tenants to adopt their highest acceptable temperature setpoints under a non-cooperative game setting. Further analysis considering distinct relative humidity setpoints shows that our proposed scheme also properly and inherently addresses the attribution of humidity control power.


2022 ◽  
Vol 9 ◽  
Author(s):  
Yicen Zhang ◽  
Yang Du ◽  
Xiaochen Lu ◽  
Pan Zhao ◽  
Yiping Dai

The wide utilization of solar energy is beneficial for the emission reduction of carbon dioxide. This paper proposes a novel power cycle system driven by solar energy, which consists of a recompression supercritical carbon dioxide cycle (RSCO2) and an ammonia-water cooling-power cycle (ACPC). The power system operates in a “self-production and self-sale” mode, which means that the refrigeration capacity produced by the ACPC is utilized to cool the main compressor inlet fluid of the RSCO2. The comprehensive energy and exergy analyses of the proposed novel system are presented. The effects of the six parameters on the system thermodynamic performance are evaluated, which are direct normal irradiation, the ammonia concentration of a basic solution, the pinch point temperature difference of an evaporator, the effectiveness of a recuperator, the pressure ratio of the RSCO2 and the molten salt outlet temperature. The results show that compared with the stand-alone RSCO2, the net power and energy efficiency of the proposed system are improved by 15.94 and 10.61%, respectively. In addition, the increasing ammonia concentration of the basic solution leads to the rise of the ACPC refrigeration output, and the inlet temperature of the main compressor can be declined to 32.97°C with the ammonia concentration of the basic solution of 0.88. Moreover, when the effectiveness of the recuperator in RSCO2 rises up to 0.98, the system energy and exergy efficiencies can reach their maximum value of 30.68 and 33.10%, respectively.


Author(s):  
Yv-Ting Huang ◽  
Zhong-Xiao Man ◽  
Yun-Jie Xia

We study the effects of common reservoirs on the performance of an autonomous three-level quantum refrigerator. We show that the common reservoirs can result not only in additional transitions but also different types of interferences between them. For the case that the sole object to be cooled is a cold reservoir, it turns out that the cooling power can be greatly enhanced by the common reservoirs as well as by the induced interference. For the configuration that the refrigerator acts on both the cold reservoir and a qubit, we find that though the common reservoirs can improve the cooling power, which instead is detrimental to the cooling of the qubit. The interference also manifests different effects on the cooling of the cold reservoir and the qubit. Our results provide an evidence of possibility on applying the common reservoirs to enhance the performance of the refrigerator.


Author(s):  
Zhexu Li ◽  
Julian Gonzalez-Ayala ◽  
Han-Xin Yang ◽  
Juncheng Guo ◽  
A Calvo Hernandez

Abstract In the present paper, a general non-combined model of three-terminal refrigerator is established based on the low-dissipation assumption. The relation between the optimized cooling power and the corresponding coefficient of performance (COP) is analytically derived, according to which the COP at maximum cooling power (CMP) can be further determined. At two dissipation asymmetry limits, upper and lower bounds of CMP are obtained and found to be in good agreement with experimental and simulated results. Additionally, comparison of the obtained bounds with previous combined model is presented. In particular it is found that the upper bounds are the same, whereas the lower bounds are quite different. This feature indicates that the claimed universal equivalence for the combined and non-combined models under endoreversible assumption is invalid within the frame of low-dissipation assumption. Then, the equivalence between various finite-time thermodynamic models needs to be reevaluated regarding multi-terminal systems. Moreover, the correlation between the combined and non-combined models is further revealed by the derivation of the equivalent condition according to which the identical upper bounds and distinct lower bounds are theoretically shown. Finally, the proposed non-combined model is proved to be the appropriate model for describing various types of thermally driven refrigerator. This work may provide some instructive information for the further establishments and performance analyses of multi-terminal low-dissipation models.


Joule ◽  
2022 ◽  
Author(s):  
Heng Cui ◽  
Quan Zhang ◽  
Yiwen Bo ◽  
Peijia Bai ◽  
Mengyan Wang ◽  
...  

Author(s):  
Satyam Saini ◽  
Pardeep Shahi ◽  
Pratik V Bansode ◽  
Jimil M. Shah ◽  
Dereje Agonafer

Abstract Continuous rise in cloud computing and other web-based services propelled the data center proliferation seen over the past decade. Traditional data centers use vapor-compression-based cooling units that not only reduce energy efficiency but also increase operational and initial investment costs due to involved redundancies. Free air cooling and airside economization can substantially reduce the IT Equipment (ITE) cooling power consumption, which accounts for approximately 40% of energy consumption for a typical air-cooled data center. However, this cooling approach entails an inherent risk of exposing the IT equipment to harmful ultrafine particulate contaminants, thus, potentially reducing the equipment and component reliability. The present investigation attempts to quantify the effects of particulate contamination inside the data center equipment and ITE room using CFD. An analysis of the boundary conditions to be used was done by detailed modeling of IT equipment and the data center white space. Both 2-D and 3-D simulations were done for detailed analysis of particle transport within the server enclosure. An analysis of the effect of the primary pressure loss obstructions like heat sinks and DIMMs inside the server was done to visualize the localized particle concentrations within the server. A room-level simulation was then conducted to identify the most vulnerable locations of particle concentration within the data center space. The results show that parameters such as higher velocities, heat sink cutouts, and higher aspect ratio features within the server tend to increase the particle concentration inside the servers.


2021 ◽  
Author(s):  
Yao-Dong Wu ◽  
Wei-Wei Duan ◽  
Qiu-Yue Li ◽  
Yong-Liang Qin ◽  
Zhen-Fa Zi ◽  
...  

Abstract The magnetic and magnetocaloric properties were studied in a stuffed honeycomb polycrystalline antiferromagnet GdInO3. The onset temperature of antiferromagnetic ordering was observed at ~ 2.1 K. Negligible thermal and magnetic hysteresis suggest a reversible magnetocaloric effect (MCE) in the GdInO3 compound. In the magnetic field changes of 0–50 kOe and 0–70 kOe, the maximum magnetic entropy change values are 9.65 J/kg K and 18.37 J/kg K, respectively, near the liquid helium temperature, with the corresponding relative cooling power values of 115.01 J/kg and 211.31 J/kg. The MCE investigation of the polycrystalline GdInO3 serves to illuminate more exotic properties in this frustrated stuffed honeycomb magnetic system.


Energies ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 8376
Author(s):  
Abdellah Khodja ◽  
Raphael Paul ◽  
Andreas Fischer ◽  
Karl Heinz Hoffmann

Vuilleumier refrigerators provide cooling power by utilizing a heat source at temperatures above the ambient. This is particularly helpful in situations where waste heat is available and other power sources are limited. Vuilleumier refrigerators come in different technical configurations; here we analyze the thermodynamic performance of a configuration utilizing two displacer pistons with integrated regenerators. More specifically, we optimize the cooling power by optimizing the piston movement for a range of operation speeds. The optimization is based on the AS motion class for cyclic dynamics and uses an endoreversible model for the refrigerator. Our focus is on the influence of the regeneration extent present, and we find performance gains of about 17% for high regeneration extent and of about 28% for lower regeneration extent.