PAS-seq 2: A fast and sensitive method for global profiling of polyadenylated RNAs

Author(s):  
Yoseop Yoon ◽  
Lindsey V. Soles ◽  
Yongsheng Shi
1992 ◽  
Vol 68 (02) ◽  
pp. 160-164 ◽  
Author(s):  
P J Braun ◽  
K M Szewczyk

SummaryPlasma levels of total prothrombin and fully-carboxylated (native) prothrombin were compared with results of prothrombin time (PT) assays for patients undergoing oral anticoagulant therapy. Mean concentrations of total and native prothrombin in non-anticoagulated patients were 119 ± 13 µg/ml and 118 ± 22 µg/ml, respectively. In anticoagulated patients, INR values ranged as high as 9, and levels of total prothrombin and native prothrombin decreased with increasing INR to minimum values of 40 µg/ml and 5 µg/ml, respectively. Des-carboxy-prothrombin increased with INR, to a maximum of 60 µg/ml. The strongest correlation was observed between native prothrombin and the reciprocal of the INR (1/INR) (r = 0.89, slope = 122 µg/ml, n = 200). These results indicated that native prothrombin varied over a wider range and was more closely related to INR values than either total or des-carboxy-prothrombin. Levels of native prothrombin were decreased 2-fold from normal levels at INR = 2, indicating that the native prothrombin antigen assay may be a sensitive method for monitoring low-dose oral anticoagulant therapy. The inverse relationship between concentration of native prothrombin and INR may help in identification of appropriate therapeutic ranges for oral anticoagulant therapy.


1993 ◽  
Vol 34 (4) ◽  
pp. 376-380 ◽  
Author(s):  
J. Merikanto ◽  
S. -O. Hietala ◽  
F. Lithner ◽  
E. Hagg ◽  
M. Paivansalo

2018 ◽  
Author(s):  
Maykel Hernández-Mesa ◽  
David Moreno-González ◽  
Carmen Cruces-Blanco ◽  
Ana M. García-Campaña

2010 ◽  
Vol 21 (6) ◽  
pp. 1426-1437
Author(s):  
Jia-Jing LI ◽  
Zhi-Yin LIANG ◽  
Tao WEI ◽  
Wei ZOU ◽  
Jian MAO
Keyword(s):  

2020 ◽  
Vol 16 ◽  
Author(s):  
Ikko Mikami ◽  
Eri Shibayama ◽  
Kengo Takagi

Background: Determination of a reducing substance based on the reaction between Ce(IV) and a reducing substance and fluorescence detection of Ce(III) generated has been reported as a selective and sensitive method. However, this method could not be applied to the determination of alcohol due to the low reaction rate of alcohol and Ce(IV). Objective: We found that thiosulfate catalytically enhanced reaction of alcohols (such as, methanol, ethanol, and propanol) and Ce(IV). Utilizing this effect, we developed a new method for the determination of alcohols. Results: In the presence of thiosulfate, an increase in fluorescence intensity was detected by injecting alcohol at concentrations of several millimolar, whereas it was not observed even at the concentration of 10% v/v (2 M for ethanol) in the absence of thiosulfate. The optimum detection conditions were determined to be 4.0 mM Ce(IV) sulfate and 0.50 mM thiosulfate, and the detection limit (S/N = 3) of ethanol under these conditions was 1 mM. In the calibration curves, changes in the slope were observed when the alcohol concentrations were approximately 10–25 mM. Using a thiosulfate solution containing ethanol as the reaction solution, a calibration curve without any change in slope was obtained, although the concentration of ethanol at the detection limit increased. The alcohols in the liquor and fuel were successfully analyzed using the proposed detection method as a postcolumn reaction. Conclusion: This new alcohol detection method using a versatile fluorescence detector can be applied to the postcolumn reaction of HPLC omitting need of time-consuming pretreatment processes.


2021 ◽  
Vol 132 ◽  
pp. S275
Author(s):  
Alison Muir ◽  
Juliana Troiani ◽  
Alicia Mosley ◽  
Zhiqian Fan ◽  
Matthew Dulik ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document