Optimization of an enzyme-coupling method by spectrophotometer for serum adenosine deaminase: As a candidate reference method

2019 ◽  
Vol 587 ◽  
pp. 113462
Author(s):  
Liqiao Han ◽  
Xiaoting Huang ◽  
Jianbing Wang ◽  
Haibiao Lin ◽  
Qiaoxuan Zhang ◽  
...  
2014 ◽  
Vol 596 ◽  
pp. 826-829
Author(s):  
Qing Song Wei ◽  
Zhe Chen ◽  
Yun Han Luo ◽  
Yue Ma ◽  
Xiao Li He ◽  
...  

A coupler of single mode fiber with photonic crystal fiber with a coupling ratio of 0 to 90% was fabricated with a new method called Auto-deposition Fused Side-adhere. A model for coupler of side-polished single mode fiber with side-polished photonic crystal fiber was established which proves it feasible to make such a coupler practically. In the range of 1520~1620nm, the Wavelength Dependent Loss (WDL) of the through port was 0.3dB and of the coupled port was 5dB. The Polarization Dependent Loss of through port was 0.25dB and 0.31dB at 1310nm and 1550nm, and the WDL of coupled port was 1.46dB and 1.75dB. When temperature changed from 10°C to 80°C and humidity changed from 10% to 70%, coupling ratio changed about 7% to 16%. It can be concluded that a steady coupler of single mode fiber with photonic crystal fiber can be made with the Auto-deposition Fused Side-adhere Coupling method, which can give a reference method and lay an experimental foundation for the fabrication of photonic crystal fiber coupler.


1990 ◽  
Vol 167 (1) ◽  
pp. 9-15 ◽  
Author(s):  
Pascal Michalon ◽  
Roger Couturier ◽  
Marie-Françoise Hacques ◽  
Guy Favre-Bonvin ◽  
Albert Ville ◽  
...  

1994 ◽  
Vol 72 (01) ◽  
pp. 084-088 ◽  
Author(s):  
E M Duncan ◽  
C R Casey ◽  
B M Duncan ◽  
J V Lloyd

SummaryThe aim of this study was to determine whether the concentration of trisodium citrate used to anticoagulate blood has an effect on the INR of the sample and the ISI of the thromboplastin. Five thromboplastins including and Australian reference material were used to measure the prothrombin time of normal and patient samples collected into two concentrations of trisodium citrate - 109 mM and 129 mM. There was no effect of citrate concentration on the INRs determined with the reference material. However for the other four thromboplastins there was a significant difference between INRs for the two citrate groups. The prothrombin times of the samples collected into 129 mM were longer than those collected into 109 mM. This difference was only slight in normal plasma but more marked in patients receiving oral anticoagulants, causing the INRs for patient plasmas collected into 129 mM citrate to be higher then the corresponding samples collected into 109 mM citrate.From orthogonal regression of log prothrombin times by the reference method against each thromboplastin, we found that the ISI for each thromboplastin was approximately 10% lower when determined with samples collected into 129 mM citrate than with samples collected into 109 mM. These results suggest that the concentration of trisodium citrate used for collection of blood samples can affect the calculation of the INR and the calibration of the ISI of thromboplastin. This was found both for commercial thromboplastins prepared by tissue extraction and for a recombinant tissue factor.


2011 ◽  
Vol 3 (10) ◽  
pp. 1-3 ◽  
Author(s):  
Dr. Amit P Trivedi ◽  
◽  
Dr. Kiran P Chauhan ◽  
Dr. N Haridas Dr. N Haridas

2017 ◽  
Vol 20 (1) ◽  
pp. 22-27
Author(s):  
O. Tsakanyan ◽  
◽  
V. Goloshchapov ◽  
S. Koshel ◽  
N. Ganzha ◽  
...  
Keyword(s):  

2007 ◽  
Vol 3 (1) ◽  
pp. 89-113
Author(s):  
Zoltán Gillay ◽  
László Fenyvesi

There was a method developed that generates the three-dimensional model of not axisymmetric produce, based on an arbitrary number of photos. The model can serve as a basis for calculating the surface area and the volume of produce. The efficiency of the reconstruction was tested on bell peppers and artificial shapes. In case of bell peppers 3-dimensional reconstruction was created from 4 images rotated in 45° angle intervals. The surface area and the volume were estimated on the basis of the reconstructed area. Furthermore, a new and simple reference method was devised to give precise results for the surface area of bell pepper. The results show that this 3D reconstruction-based surface area and volume calculation method is suitable to determine the surface area and volume of definite bell peppers with an acceptable error.


Sign in / Sign up

Export Citation Format

Share Document