Clinical variables predicting inappropriate use of implantable cardioverter-defibrillator in patients with coronary heart disease or nonischemic dilated cardiomyopathy

2005 ◽  
Vol 95 (2) ◽  
pp. 271-274 ◽  
Author(s):  
Dominic A.M.J. Theuns ◽  
A. Peter J. Klootwijk ◽  
Maarten L. Simoons ◽  
Luc J. Jordaens
2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Sem Briongos‐Figuero ◽  
Arcadio García‐Alberola ◽  
Jerónimo Rubio ◽  
José María Segura ◽  
Aníbal Rodríguez ◽  
...  

Background Large‐scale studies describing modern populations using an implantable cardioverter‐defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real‐world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes. From November 2005 to November 2017, 4296 patients were followed up. After 46.6±27.3 months, 16 067 episodes of sustained ventricular arrhythmia occurred in 1344 patients (31.3%). Appropriate ICD therapy occurred in 27.3% of study population. Patients with ischemic cardiomyopathy (hazard ratio [HR], 1.51; 95% CI, 1.29–1.78), dilated cardiomyopathy (HR, 1.28; 95% CI, 1.07–1.53), and valvular heart disease (HR, 1.94; 95% CI, 1.43–2.62) exhibited a higher risk of appropriate ICD therapies, whereas patients with hypertrophic cardiomyopathy (HR, 0.72; 95% CI, 0.54–0.96) and Brugada syndrome (HR, 0.25; 95% CI, 0.14–0.45) showed a lower risk. All‐cause death was 13.4% at follow‐up. Ischemic cardiomyopathy (HR, 3.09; 95% CI, 2.58–5.90), dilated cardiomyopathy (HR, 3.33; 95% CI, 2.18–5.10), and valvular heart disease (HR, 3.97; 95% CI, 2.25–6.99) had the worst prognoses. Delayed high‐rate detection was enabled in 39.7% of patients, and single‐zone programming occurred in 52.6% of primary prevention patients. Both parameters correlated with lower risk of first appropriate ICD therapy, with no excess risk of mortality. The rate of inappropriate shocks at follow‐up was low (6%) and did not differ among type of ICD but was lower in SmartShock‐capable devices. Conclusions Irrespective of the cause, contemporary ICD patients with heart failure–related disorders had a similar risk of ICD life‐saving interventions and death. Current ICD programming recommendations still need to be implemented. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NTC01561144.


2011 ◽  
Vol 3 (1) ◽  
pp. 77
Author(s):  
Cyril YK Ko ◽  
Jeffrey WH Fung ◽  
◽  

Sudden cardiac death (SCD) is a serious medical problem worldwide. Multiple landmark studies have demonstrated the benefit of implantable cardioverter–defibrillator (ICD) therapy in preventing SCD in at-risk patients. Although the data available in Asia are limited, the disease pattern seems to be different from that in the western world. The Asian population seems to have a lower incidence of SCD. Coronary heart disease, which is the major underlying cause of SCD in the west, may play a less important role in Asian countries. In addition, non-structural heart disease seems to be a more prevalent cause of SCD in Asia. It is thus questionable whether the results of ICD trials can be applied directly to Asian countries, as most of these trials seldom recruited Asian patients. This article will review SCD in Asia, focusing on the epidemiology and risk factors for SCD in Asia and highlighting some unique features that may be different from those seen in the western world.


2018 ◽  
Vol 41 (6) ◽  
pp. 583-588 ◽  
Author(s):  
Maria Licia Ribeiro Cury Pavão ◽  
Elerson Arfelli ◽  
Adilson Scorzoni-Filho ◽  
Anis Rassi ◽  
Antônio Pazin-Filho ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document