Analysis of the quantitative correlation between the heat source temperature and the critical temperature of the optimal pure working fluid for subcritical organic Rankine cycles

2016 ◽  
Vol 99 ◽  
pp. 383-391 ◽  
Author(s):  
Huixing Zhai ◽  
Qingsong An ◽  
Lin Shi
2011 ◽  
Vol 32 (3) ◽  
pp. 57-70 ◽  
Author(s):  
Dariusz Mikielewicz ◽  
Jarosław Mikielewicz

Utilisation of bleed steam heat to increase the upper heat source temperature in low-temperature ORC In the paper presented is a novel concept to utilize the heat from the turbine bleed to improve the quality of working fluid vapour in the bottoming organic Rankine cycle (ORC). That is a completely novel solution in the literature, which contributes to the increase of ORC efficiency and the overall efficiency of the combined system of the power plant and ORC plant. Calculations have been accomplished for the case when available is a flow rate of low enthalpy hot water at a temperature of 90 °C, which is used for preliminary heating of the working fluid. That hot water is obtained as a result of conversion of exhaust gases in the power plant to the energy of hot water. Then the working fluid is further heated by the bleed steam to reach 120 °C. Such vapour is subsequently directed to the turbine. In the paper 5 possible working fluids were examined, namely R134a, MM, MDM, toluene and ethanol. Only under conditions of 120 °C/40 °C the silicone oil MM showed the best performance, in all other cases the ethanol proved to be best performing fluid of all. Results are compared with the "stand alone" ORC module showing its superiority.


2020 ◽  
pp. 1-27
Author(s):  
Ahmad K. Sleiti ◽  
Wahib Al-Ammari ◽  
Mohammed Al-Khawaja

Abstract Refrigerants of the conventional cooling systems contribute to global warming and ozone depletion significantly, therefore it is necessary to develop new cooling systems that use renewable energy resources and waste heat to perform the cooling function with eco-friendly working fluids. To address this, the present study introduces and analyzes a novel regenerative thermo-mechanical refrigeration system that can be powered by renewable heat sources (solar, geothermal, or waste heat). The system consists of a novel expander-compressor unit (ECU) integrated with a vapor compression refrigeration system. The integrated system operates at the higher-performance supercritical conditions of the working fluids as opposed to the lower-performance subcritical conditions. The performance of the system is evaluated based on several indicators including the power loop efficiency, the coefficient of performance (COP) of the cooling loop, and the expander-compressor diameters. Several working fluids were selected and compared for their suitability based on their performance and environmental effects. It was found that for heat source temperature below 100 °C, adding the regenerator to the system has no benefit. However, the regenerator increases the power efficiency by about 1 % for a heat source temperature above 130 °C. This was achieved with a very small size regenerator (Dr = 6.5 mm, Lr = 142 mm). Results show that there is a trade-off between high-performance fluids and their environmental effects. Using R32 as a working fluid at heat source temperature Th=150 °C and cold temperature Tc1=40 °C, the system produces a cooling capacity of 1 kW with power efficiency of 10.23 %, expander diameter of 53.12 mm, and compressor diameter of 75.4mm.


Energy ◽  
2015 ◽  
Vol 88 ◽  
pp. 897-906 ◽  
Author(s):  
Wei Liu ◽  
Dominik Meinel ◽  
Moritz Gleinser ◽  
Christoph Wieland ◽  
Hartmut Spliethoff

Entropy ◽  
2020 ◽  
Vol 23 (1) ◽  
pp. 43
Author(s):  
Guanglin Liu ◽  
Qingyang Wang ◽  
Jinliang Xu ◽  
Zheng Miao

Organic Rankine cycle (ORC) power generation is an effective way to convert medium and low temperature heat into high-grade electricity. In this paper, the subcritical saturated organic Rankine cycle system with a heat source temperature of 100~150 °C is studied with four different organic working fluids. The variations of the exergy efficiencies for the single-stage/two-stage systems, heaters, and condensers with the heat source temperature are analyzed. Based on the condition when the exergy efficiency is maximized for the two-stage system, the effects of the mass split ratio of the geothermal fluid flowing into the preheaters and the exergy efficiency of the heater are studied. The main conclusions include: The exergy efficiency of the two-stage system is affected by the evaporation temperatures of the organic working fluid in both the high temperature and low temperature cycles and has a maximum value. Under the same heat sink and heat source parameters, the exergy efficiency of the two-stage system is larger than that of the single-stage system. For example, when the heat source temperature is 130 °C, the exergy efficiency of the two-stage system is increased by 9.4% compared with the single-stage system. For the two-stage system, analysis of the four organic working fluids shows that R600a has the highest exergy efficiency, although R600a is only suitable for heat source temperature below 140 °C, while other working fluids can be used in systems with higher heat source temperatures. The mass split ratio of the fluid in the preheaters of the two-stage system depends on the working fluid and the heat source temperature. As the heat source temperature increases, the range of the split ratio becomes narrower, and the curves are in the shape of an isosceles triangle. Therefore, different working fluids are suitable for different heat source temperatures, and appropriate working fluid and split ratio should be determined based on the heat source parameters.


2018 ◽  
Vol 140 (5) ◽  
Author(s):  
Bhargav Pandya ◽  
Vinay Kumar ◽  
Jatin Patel ◽  
V. K. Matawala

This comprehensive investigation has been executed to compare the thermodynamic performance and optimization of LiCl–H2O and LiBr–H2O type absorption system integrated with flat-plate collectors (FPC), parabolic-trough collectors (PTC), evacuated-tube collectors (ETC), and compound parabolic collectors (CPC). A model of 10 kW is analyzed in engineering equation solver (ees) from thermodynamic perspectives. Solar collectors are integrated with a storage tank which fueled the LiCl–H2O and LiBr–H2O vapor absorption system to produce refrigeration at 7 °C in evaporator for Gujarat Region of India. The main objective includes the evaluation and optimization of critical performance and design parameters to exhibit the best working fluid pair and collector type. Optimum heat source temperature corresponding to energetic and exergetic aspects for LiCl–H2O pair is lower than that of LiBr–H2O pair for all collectors. Simulation shows that FPC has lowest capital cost, exergetic performance wise PTC is optimum, and ETC requires lowest collector area. On the basis of overall evaluation, solar absorption cooling systems are better to be powered by ETC with LiCl–H2O working fluid pair.


2021 ◽  
Author(s):  
Aram Mohammed Ahmed ◽  
Attila R. Imre

AbstractThermodynamic efficiency is a crucial factor of a power cycle. Most of the studies indicated that efficiency increases with increasing heat source temperature, regardless of heat source type. Although this assumption generally is right, when the heat source temperature is close to the critical temperature, increasing the heat source temperature can decrease efficiency. Therefore, in some cases, the increase in the source temperature, like using improved or more collectors for a solar heat source can have a double negative effect by decreasing efficiency while increasing the installation costs. In this paper, a comparison of the CO2 subcritical cycle and the Trilateral Flash Cycle will be presented to show the potential negative effect of heat source temperature increase.


2019 ◽  
Vol 9 (15) ◽  
pp. 3024 ◽  
Author(s):  
Chinedu K. Unamba ◽  
Paul Sapin ◽  
Xiaoya Li ◽  
Jian Song ◽  
Kai Wang ◽  
...  

Several heat-to-power conversion technologies are being proposed as suitable for waste-heat recovery (WHR) applications, including thermoelectric generators, hot-air (e.g., Ericsson or Stirling) engines and vapour-cycle engines such as steam or organic Rankine cycle (ORC) power systems. The latter technology has demonstrated the highest efficiencies at small and intermediate scales and low to medium heat-source temperatures and is considered a suitable option for WHR in relevant applications. However, ORC systems experience variations in performance at part-load or off-design conditions, which need to be predicted accurately by empirical or physics-based models if one is to assess accurately the techno-economic potential of such ORC-WHR solutions. This paper presents results from an experimental investigation of the part-load performance of a 1-kWe ORC engine, operated with R245fa as a working fluid, with the aim of producing high-fidelity steady-state and transient data relating to the operational performance of this system. The experimental apparatus is composed of a rotary-vane pump, brazed-plate evaporator and condenser units and a scroll expander magnetically coupled to a generator with an adjustable resistive load. An electric heater is used to provide a hot oil-stream to the evaporator, supplied at three different temperatures in the current study: 100, 120 and 140 ∘ C. The optimal operating conditions, that is, pump speed and expander load, are determined at various heat-source conditions, thus resulting in a total of 124 steady-state data points used to analyse the part-load performance of the engine. A maximum thermal efficiency of 4.2 ± 0.1% is reported for a heat-source temperature of 120 ∘ C, while a maximum net power output of 508 ± 2 W is obtained for a heat-source temperature at 140 ∘ C. For a 100- ∘ C heat source, a maximum exergy efficiency of 18.7 ± 0.3% is achieved. A detailed exergy analysis allows us to quantify the contribution of each component to the overall exergy destruction. The share of the evaporator, condenser and expander components are all significant for the three heat-source conditions, while the exergy destroyed in the pump is negligible by comparison (below 4%). The data can be used for the development and validation of advanced models capable of steady-state part-load and off-design performance predictions, as well as predictions of the transient/dynamic operation of ORC systems.