Evaluation of high-linearity bone radiation detectors exposed to gamma-rays via FTIR measurements

2021 ◽  
Vol 170 ◽  
pp. 109598
Author(s):  
Lucas Nonato de Oliveira ◽  
Eriberto Oliveira do Nascimento ◽  
Pedro de Aquino Morais Júnior ◽  
Patrícia de Lara Antonio ◽  
Linda V.E. Caldas
Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3376
Author(s):  
Xi Zhang ◽  
Qiangqiang Xie ◽  
Siwei Xie ◽  
Xin Yu ◽  
Jianfeng Xu ◽  
...  

Portable radiation detectors are widely used in environmental radiation detection and medical imaging due to their portability feature, high detection efficiency, and large field of view. Lutetium-yttrium oxyorthosilicate (LYSO) is a widely used scintillator in gamma radiation detection. However, the structure and the arrangement of scintillators limit the sensitivity and detection accuracy of these radiation detectors. In this study, a novel portable sensor based on a monolithic LYSO ring was developed for the detection of environmental radiation through simulation, followed by construction and assessments. Monte Carlo simulations were utilized to prove the detection of gamma rays at 511 keV by the developed sensor. The simulations data, including energy resolutions, decoding errors, and sensitivity, showed good potential for the detection of gamma rays by the as-obtained sensor. The experimental results using the VA method revealed decoding errors in the energy window width of 50 keV less than 2°. The average error was estimated at 0.67°, a sufficient value for the detection of gamma radiation. In sum, the proposed radiation sensor appears promising for the construction of high-performance radiation detectors and systems.


1993 ◽  
Vol 302 ◽  
Author(s):  
Dominique C. David ◽  
R. B. James ◽  
H. Feemster ◽  
R. Anderson ◽  
A. J. Antolak ◽  
...  

ABSTRACTSignificant developments have occurred in the technology of room-temperature PbI2 nuclear sensors which lead to some improvements in the detection of high energy gamma-rays. Discussion of crystal growth, purification, monitoring purification, and detector processing are reviewed as they relate to device performance.


1967 ◽  
Vol 31 ◽  
pp. 469-471
Author(s):  
J. G. Duthie ◽  
M. P. Savedoff ◽  
R. Cobb
Keyword(s):  

A source of gamma rays has been found at right ascension 20h15m, declination +35°, with an uncertainty of 6° in each coordinate. Its flux is (1·5 ± 0·8) x 10-4photons cm-2sec-1at 100 MeV. Possible identifications are reviewed, but no conclusion is reached. The mechanism producing the radiation is also uncertain.


1994 ◽  
Vol 144 ◽  
pp. 635-639
Author(s):  
J. Baláž ◽  
A. V. Dmitriev ◽  
M. A. Kovalevskaya ◽  
K. Kudela ◽  
S. N. Kuznetsov ◽  
...  

AbstractThe experiment SONG (SOlar Neutron and Gamma rays) for the low altitude satellite CORONAS-I is described. The instrument is capable to provide gamma-ray line and continuum detection in the energy range 0.1 – 100 MeV as well as detection of neutrons with energies above 30 MeV. As a by-product, the electrons in the range 11 – 108 MeV will be measured too. The pulse shape discrimination technique (PSD) is used.


Author(s):  
T. M. Seed ◽  
M. H. Sanderson ◽  
D. L. Gutzeit ◽  
T. E. Fritz ◽  
D. V. Tolle ◽  
...  

The developing mammalian fetus is thought to be highly sensitive to ionizing radiation. However, dose, dose-rate relationships are not well established, especially the long term effects of protracted, low-dose exposure. A previous report (1) has indicated that bred beagle bitches exposed to daily doses of 5 to 35 R 60Co gamma rays throughout gestation can produce viable, seemingly normal offspring. Puppies irradiated in utero are distinguishable from controls only by their smaller size, dental abnormalities, and, in adulthood, by their inability to bear young.We report here our preliminary microscopic evaluation of ovarian pathology in young pups continuously irradiated throughout gestation at daily (22 h/day) dose rates of either 0.4, 1.0, 2.5, or 5.0 R/day of gamma rays from an attenuated 60Co source. Pups from non-irradiated bitches served as controls. Experimental animals were evaluated clinically and hematologically (control + 5.0 R/day pups) at regular intervals.


Sign in / Sign up

Export Citation Format

Share Document