Adverse Reactions to Metal Debris in Metal-On-Polyethylene Total Hip Arthroplasty Using a Titanium-Molybdenum-Zirconium-Iron Alloy Stem

2015 ◽  
Vol 30 (2) ◽  
pp. 277-281 ◽  
Author(s):  
Manish Kiran ◽  
Petros J. Boscainos
2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


Author(s):  
Lauren N Pearson ◽  
Robert L Schmidt ◽  
Kenneth Cahoon ◽  
Christopher E Pelt

Abstract Background Total nucleated cell (TNC) count and differential are used to classify joint effusions as inflammatory or noninflammatory. Further diagnostic evaluation and management is contingent on this classification. TNC count can be measured by automated analyzers or by manual assessment using a hemocytometer. Studies have raised concerns regarding the accuracy of TNC counts measured by automated instruments, particularly in the setting of joint arthroplasty. The objective of this study was to determine whether metallosis, a complication of total hip arthroplasty in which metal debris accumulates in periprosthetic tissues and synovial fluid, is associated with inaccurate TNC counts in synovial fluid. Methods We compared the accuracy of cell counts measured by the Sysmex XN-1000 and Beckman Coulter Iris iQ200 with the gold standard of manual assessment using a hemocytometer in synovial fluid from patients with suspected metallosis and in fluid obtained from controls from patients with native joints and a history of arthroplasty for other indications. Results TNC counts produced by automated analyzers were associated with increased levels of discordance (relative to manual counts) in patients with metallosis. Metallosis was not associated with increased levels of discordance for RBC counts or WBC differentials. The Sysmex XN flagged all but 1 metallosis sample for manual verification of the results. Conclusions Automated methods are generally reliable for analysis of synovial fluid. TNC counts can be inaccurate in the context of metallosis following total hip arthroplasty. Laboratories should correlate automated cell counts with a microscopic assessment of the specimen, as recommended by instrument manufacturers.


2016 ◽  
Vol 2016 ◽  
pp. 1-5
Author(s):  
Tomoya Takasago ◽  
Tomohiro Goto ◽  
Keizo Wada ◽  
Daisuke Hamada ◽  
Toshiyuki Iwame ◽  
...  

The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a metal femoral head provides satisfactory results. We report an unusual case of progressive osteolysis due to metallosis that developed after revision THA for ceramic liner dissociation without a liner fracture performed using a metal femoral head and polyethylene liner. The residual metal debris and abnormal pumping motion of the polyethylene liner due to the breakage of the locking system or the aspherical metal shell being abraded by the ceramic head seemed to be the cause of the progressive osteolysis.


2017 ◽  
Vol 21 (05) ◽  
pp. 616-629 ◽  
Author(s):  
Iman Khodarahmi ◽  
Jan Fritz

AbstractRecent metal artifact reduction techniques in magnetic resonance imaging (MRI) have sparked a new aera in visualization of the peri-implant region and assessment of failing orthopaedic hardware. Modes of failure after total hip arthroplasty can be classified into four broad categories: osseous abnormalities, implant instability and dislocation, implant-associated synovitis, and soft tissue abnormalities. Although MRI is complementary to plain radiography and computed tomography to diagnose the first two categories, it is paramount to investigate the complications related to the synovium and soft tissues. We review the most common modes of failure of hip implants and the MRI characteristics of various causes of pain and dysfunction after hip arthroplasty including osseous stress reaction and fracture, implant loosening, implant instability, polyethylene wear–induced synovitis, adverse reaction to metal debris, infection, hematoma, recurrent hemarthrosis, heterotopic ossification, muscle, tendon, and nerve abnormalities, and periprosthetic neoplasms.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Kilian Elia Stockhausen ◽  
Christoph Riedel ◽  
Alex Victoria Belinski ◽  
Dorothea Rothe ◽  
Thorsten Gehrke ◽  
...  

AbstractDegradation at the modular head-neck interface in total hip arthroplasty (THA) is predominately expressed in the form of corrosion and fretting, potentially causing peri-prosthetic failure by adverse reactions to metal debris. This retrieval study aimed to quantify variations in stem taper surface topographies and to assess the influence on the formation of corrosion and/or fretting in titanium alloy stem tapers combined with metal and ceramic heads. Four hip stem designs (Alloclassic, CLS, Bicontact and SL-Plus) were characterized using high-resolution 3D microscopy, and corrosion and fretting were rated using the Goldberg scoring scheme. Quantification of the taper surface topographies revealed a high variability in surface characteristics between threaded stem tapers: Alloclassic and CLS tapers feature deeply threaded trapezoid-shaped profiles with thread heights over 65 µm. The sawtooth-shaped Bicontact and triangular SL-Plus taper are characterized by low thread heights below 14 µm. Significantly lower corrosion and fretting scores were observed in lightly threaded compared to deeply threaded tapers in ceramic head combinations. No significant differences in corrosion or fretting scores with thread height were found in pairings with metal heads. Understanding the relationship between stem taper surface topography and the formation of corrosion and fretting could help to improve the performance of modern THAs and lead to longer-lasting clinical results.


2018 ◽  
Vol 100-B (6) ◽  
pp. 720-724 ◽  
Author(s):  
H. B. Waterson ◽  
M. R. Whitehouse ◽  
N. V. Greidanus ◽  
D. S. Garbuz ◽  
B. A. Masri ◽  
...  

AimsFretting and corrosion at the modular head/neck junction, known as trunnionosis, in total hip arthroplasty (THA) is a cause of adverse reaction to metal debris (ARMD). We describe the outcome of revision of metal-on-polyethylene (MoP) THA for ARMD due to trunnionosis with emphasis on the risk of major complications.Patients and MethodsA total of 36 patients with a MoP THA who underwent revision for ARMD due to trunnionosis were identified. Three were excluded as their revision had been to another metal head. The remaining 33 were revised to a ceramic head with a titanium sleeve. We describe the presentation, revision findings, and risk of complications in these patients.ResultsThe patients presented with pain, swelling, stiffness, or instability and an inflammatory mass was confirmed radiologically. Macroscopic material deposition on the trunnion was seen in all patients, associated with ARMD. Following revision, six (18.2%) dislocated, requiring further revision in four. Three (9.1%) developed a deep infection and six (18.2%) had significant persistent pain without an obvious cause. One developed a femoral artery thrombosis after excision of an iliofemoral pseudotumor, requiring a thrombectomy.ConclusionThe risk of serious complications following revision MoP THA for ARMD associated with trunnionosis is high. In the presence of extensive tissue damage, a constrained liner or dual mobility construct is recommended in these patients. Cite this article: Bone Joint J 2018;100-B:720–4.


2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Peter Caspar Bünemann ◽  
Stefan Luck ◽  
Malte Ohlmeier ◽  
Thorsten Gehrke ◽  
Tobias Malte Ballhause

Osteoarthritis of the hip joint (coxarthrosis) is the most common hip disease in adults. Since the 1960s, total hip arthroplasty (THA) has made great progress and is nowadays one of the most frequently used procedures in orthopedic surgery. Different bearing concepts exist in various implant designs. A metal-on-metal bearing can create metal debris and lead to metallosis. We present a unique case of a 78-year old woman, who received hip resurfacing with a McMinn-like prosthesis 15 years ago. Over the cause of time, metallosis developed and created a bone cyst in the Os ilium, and osteolysis led to a dislocation of the femoral implant. A minor stumble fall led to a fracture of the Os ilium. We present our treatment method with implantation of a cemented THA and refill of the bone cyst with bone from allogene femoral heads. The surgery led to a reconstruction of the physiological center of rotation in the hip. Consequently, to the inpatient stay, the patient took part in a follow-up treatment with intensive physiotherapy. Taken together, the results after total hip arthroplasty are more superior to other hip surface replacements in terms of longevity and patient satisfaction. Especially, metal-on-metal bearing couples carry a great risk of metallosis, which goes a long with pseudotumors, osteolysis, and the elevated metal ions in the blood. Since this case is unique in the literature, no guidelines are noted for surgical treatment. In our opinion, a periprosthetic fracture of this type should be performed in a hospital using extensive endoprosthetic expertise.


2018 ◽  
Vol 52 (1) ◽  
pp. 26-30
Author(s):  
Jagandeep S Virk ◽  
Sudhir K Garg ◽  
Purnima Aggarwal ◽  
Reetu Kundu ◽  
Robin Bohat

ABSTRACT Second-generation metal-on-metal (MoM) total hip arthroplasty (THA) was introduced to overcome the complications associated with the wear debris from ultrahigh molecular weight polyethylene (UHMWPE). However, a new type of complication began appearing, described as aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL). Patients with ALVAL complain of pain and, in some cases, extensive swelling around the hip joint known as “pseudotumors.” The cause is unknown and probably multifactorial. This may be an adverse reaction to an excess of particulate metal wear debris or a hypersensitivity reaction to a normal amount of metal debris. Surgical findings are typical and symptoms tend to resolve reliably following conversion to an alternative bearing surface. We report one such case of a 55-year-old male, who underwent a revision of bearing surfaces because of ALVAL and pseudotumor formation following an MoM THA at our institute. How to cite this article Virk JS, Garg SK, Aggarwal P, Kundu R, Bohat R. Pseudotumor in Metal-on-metal Total Hip Arthroplasty: An Unusual Complication. J Postgrad Med Edu Res 2018;52(1):26-30.


2017 ◽  
Vol 106 (4) ◽  
pp. 342-349 ◽  
Author(s):  
H. Mäntymäki ◽  
M. Junnila ◽  
P. Lankinen ◽  
M. Seppänen ◽  
T. Vahlberg ◽  
...  

Background and Aims: An adverse reaction to metal debris is a known complication after large diameter head metal-on-metal total hip arthroplasty. However, the failure rate varies depending on the implant design. Therefore, we investigated the prevalence of adverse reaction to metal debris, as well as the symptoms and risk factors after undergoing a ReCap-M2a-Magnum large diameter head metal-on-metal total hip arthroplasty. Materials and Methods: Between 2005 and 2012, 1188 patients (1329 hips) underwent ReCap-M2a-Magnum total hip arthroplasty at our institution. Systematic screening for adverse reaction to metal debris was arranged using the Oxford Hip Score questionnaire, hip and pelvic radiographs, and assessments of the serum chromium and cobalt ion levels. Clinical evaluation and magnetic resonance imaging were performed for the symptomatic patients, as well as those with either chromium or cobalt ion levels ⩾5 µg/L. The prevalence of adverse reaction to metal debris after ReCap-M2a-Magnum total hip arthroplasty was assessed, and the risk factors for adverse reaction to metal debris were evaluated using logistic regression. The mean follow-up time was 5.2 (0.003–9.1) years. This study was an extension of a previous study conducted at our institution with 80 patients. Results: In total, 33 patients (33 hips, 2.5% of all hips) required a revision operation due to adverse reaction to metal debris. Moreover, 157 hips exhibited definitive adverse reaction to metal debris, but a revision operation was not performed (157 of 1329 hips, 11.8% of all hips). Overall, 190 out of 1329 (14.3%) hips had definitive adverse reaction to metal debris. Pain, subluxation sensation, clicking, swelling, a small head size, and a fair/poor Oxford Hip Score were associated with definitive adverse reaction to metal debris. Conclusion: We found a high prevalence of adverse reaction to metal debris in the ReCap-M2a-Magnum total hip arthroplasty patients in this study; however, most of the patients did not require revision operations.