Microfluidic chip coupled with optical biosensors for simultaneous detection of multiple analytes: A review

2019 ◽  
Vol 126 ◽  
pp. 697-706 ◽  
Author(s):  
Zerong Liao ◽  
Yang Zhang ◽  
Yongrui Li ◽  
Yunfei Miao ◽  
Shimeng Gao ◽  
...  
Author(s):  
Shancy Augustine ◽  
Pan Gu ◽  
Xiangjun Zheng ◽  
Toshikazu Nishida ◽  
Z. Hugh Fan

There is a need for low-cost immunoassays that measure the presence and concentration of multiple harmful agents in one device. Currently, comparable immunoassays employ a one-analyte-per-test format that is time consuming and not cost effective for the requirement of detecting multiple analytes in a single sample. For instance, if a spectrum of harmful agents, including E. coli O157, cholera toxin, and Salmonella typhimurium, should be simultaneously monitored in foods and drinking water, then a one-analyte-per-test would be inefficient. This work demonstrates a platform capable of simultaneous detection of multiple analytes in a single, low-cost, microvalve array-enabled multiplexed immunoassay. This multiplexed immunoassay platform is demonstrated in a prototype COC (cyclic olefin copolymer) device with a 2×3 array in which 6 analytes can be detected simultaneously. In order to contain and regulate the flow of reagents in the multichannel device, an array of microfluidic valves actuated by a thermally expandable material and microfabricated resistors have been developed to direct the flow to the necessary assay sites. The microvalve-based immunoassay is shown to be reliable, easy to operate, and compatible with large-scale integration. The all-plastic microvalves use paraffin wax as the thermally sensitive material which drastically reduces power consumption by latching upon closing so that pulsed power is required only to close and latch the microvalve until it is necessary to re-open the valve. The multiplexed detection scheme has been demonstrated by using three proteins, C reactive protein (CRP) and transferrin, both of which are biomarkers associated with traumatic brain injury (TBI) as well as bovine serum albumin (BSA) as the negative control. Since there are no external bulky pneumatic accessories required to operate/latch the microvalves in the device, this compact, thermally actuated and latching microvalve-enabled multiplexed immunoassay has the potential to realize a portable, low power, battery operated microfluidic device for biological assays.


Author(s):  
Frances S. Ligler ◽  
James W. Hazzard ◽  
Joel P. Golden ◽  
Chris A. Rowe

2021 ◽  
Author(s):  
Yan Zhang ◽  
Taisuke Kojima ◽  
Ge-Ah Kim ◽  
Monica P. McNerney ◽  
Shuichi Takayama ◽  
...  

AbstractSimultaneous detection of multiple analytes from a single sample (multiplexing), particularly when at the point of need, can guide complex decision-making without increasing the required sample volume or cost per test. Despite recent advances, multiplexing still typically faces the critical limitation of measuring only one type of molecule per assay platform – for example, only small molecules or only nucleic acids. In this work, we address this bottleneck with a customizable platform that integrates cell-free expression (CFE) with a polymer-based aqueous two-phase system (ATPS) to produce membrane-less “protocells” containing transcription and translation machinery used for analyte detection. Multiple protocells are arrayed in microwells where each protocell droplet performs distinct reactions to detect chemically diverse targets including small molecules, minerals, and nucleic acid sequences, all from the same sample. We demonstrate that these protocell arrays can measure analytes in a human biofluid matrix, maintain function after lyophilization and rehydration, and produce visually interpretable readouts, illustrating its potential for application as a minimal-equipment, field-deployable, multi-analyte detection tool.


2021 ◽  
Author(s):  
Binfeng Yin ◽  
Xinhua Wan ◽  
Mingzhu Yang ◽  
Changcheng Qian ◽  
A S M Muhtasim Fuad Sohan

Abstract Background: Simultaneous and timely detection of C-reactive protein (CRP), procalcitonin (PCT), and interleukin-6 (IL-6) provides effective information for the accurate diagnosis of infections. Early diagnosis and classification of infections increase the cure rate while decreasing complications, which is significant for severe infections, especially for war surgery. However, traditional methods rely on laborious operations and bulky devices. On the other hand, point-of-care (POC) methods suffer from limited robustness and accuracy. Therefore, it is of urgent demand to develop POC devices for rapid and accurate diagnosis of infections to fulfill on-site militarized requirements.Methods: We developed a wave-shaped microfluidic chip (WMC) assisted multiplexed detection platform (WMC-MDP). WMC-MDP reduces detection time and improves repeatability through premixing of the samples and reaction of the reagents. We further combined the detection platform with the streptavidin-biotin (SA-B) amplified system to enhance the sensitivity while using chemiluminescence (CL) intensity as signal readout. We realized simultaneous detection of CRP, PCT, and IL-6 on the detection platform and evaluated the sensitivity, linear range, selectivity, and repeatability. Finally, we finished detecting 15 samples from volunteers and compared the results with commercial ELISA kits.Results: Detection of CRP, PCT, and IL-6 exhibited good linear relationships between CL intensities and concentrations in the range of 1.25-40 μg/mL, 0.4-12.8 ng/mL, and 50-1600 pg/mL. The limit of detection (LOD) of CRP, PCT, and IL-6 were 0.54 μg/mL, 0.11 ng/mL, and 16.25 pg/mL, respectively. WMC-MDP is capable of good adequate selectivity and repeatability. The whole detection procedure takes only 22 minutes that meets the requirements of a POC device. Results of 15 samples from volunteers were consistent with the results detected by commercial ELISA kits.Conclusion: WMC-MDP allows simultaneous, rapid, and sensitive detection of CRP, PCT, and IL-6 with satisfactory selectivity and repeatability, requiring minimal manipulation. However, WMC-MDP takes advantage of being a microfluidic device showing the coefficients of variation less than 10% enabling WMC-MDP to be a type of POCT. Therefore, WMC-MDP provides a promising alternative to point-of-care testing (POCT) of multiple biomarkers. We believe the practical application of WMC-MDP in militarized fields will revolutionize infection diagnosis for soldiers.


2018 ◽  
Vol 12 (2) ◽  
pp. 024109 ◽  
Author(s):  
Wenjia Liu ◽  
Antony Warden ◽  
Jiahui Sun ◽  
Guangxia Shen ◽  
Xianting Ding

2012 ◽  
Author(s):  
Hyoungseon Choi ◽  
Kwang Bok Kim ◽  
Changsu Jun ◽  
Taek Dong Chung ◽  
Hee Chan Kim

Sign in / Sign up

Export Citation Format

Share Document