scholarly journals Arterial pulse pressure and postoperative morbidity in high-risk surgical patients

2018 ◽  
Vol 120 (1) ◽  
pp. 94-100 ◽  
Author(s):  
G.L. Ackland ◽  
T.E.F. Abbott ◽  
R.M. Pearse ◽  
S.N. Karmali ◽  
J. Whittle ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Jean-Luc Fellahi ◽  
Emmanuel Futier ◽  
Camille Vaisse ◽  
Olivier Collange ◽  
Olivier Huet ◽  
...  

AbstractDespite a large body of evidence, the implementation of guidelines on hemodynamic optimization and goal-directed therapy remains limited in daily routine practice. To facilitate/accelerate this implementation, a panel of experts in the field proposes an approach based on six relevant questions/answers that are frequently mentioned by clinicians, using a critical appraisal of the literature and a modified Delphi process. The mean arterial pressure is a major determinant of organ perfusion, so that the authors unanimously recommend not to tolerate absolute values below 65 mmHg during surgery to reduce the risk of postoperative organ dysfunction. Despite well-identified limitations, the authors unanimously propose the use of dynamic indices to rationalize fluid therapy in a large number of patients undergoing non-cardiac surgery, pending the implementation of a “validity criteria checklist” before applying volume expansion. The authors recommend with a good agreement mini- or non-invasive stroke volume/cardiac output monitoring in moderate to high-risk surgical patients to optimize fluid therapy on an individual basis and avoid volume overload. The authors propose to use fluids and vasoconstrictors in combination to achieve optimal blood flow and maintain perfusion pressure above the thresholds considered at risk. Although purchase of disposable sensors and stand-alone monitors will result in additional costs, the authors unanimously acknowledge that there are data strongly suggesting this may be counterbalanced by a sustained reduction in postoperative morbidity and hospital lengths of stay. Beside existing guidelines, knowledge and explicit clinical reasoning tools followed by decision algorithms are mandatory to implement individualized hemodynamic optimization strategies and reduce postoperative morbidity and duration of hospital stay in high-risk surgical patients.


1993 ◽  
Vol 264 (5) ◽  
pp. R1024-R1030 ◽  
Author(s):  
P. Norsk ◽  
P. Ellegaard ◽  
R. Videbaek ◽  
C. Stadeager ◽  
F. Jessen ◽  
...  

The hypothesis was tested that narrowing of arterial pulse pressure (PP) is a determinant of arginine vasopressin (AVP) release in humans. Six normal males completed a two-step lower body negative pressure (LBNP) protocol of -20 and -50 mmHg, respectively, for 10 min each. None of these subjects experienced presyncopal symptoms. Arterial plasma AVP and plasma renin activity (PRA) (at 2-min intervals) only increased subsequent to a decrease in PP (invasive brachial arterial measurements) and stroke volume (ultrasound Doppler technique, n = 4). Simultaneously, mean arterial pressure did not change. A selective decrease in central venous pressure and left atrial diameter (echocardiography, n = 4) at LBNP of -20 mmHg did not affect AVP or PRA, whereas arterial plasma norepinephrine increased (n = 4). During LBNP, significant (P < 0.05) intraindividual linear correlations were observed between log(AVP) and PP in four of the subjects with r values from -0.75 to -0.99 and between log(PRA) and PP in all six subjects with r values from -0.89 to -0.98. In conclusion, these results are in compliance with the hypothesis that narrowing of PP in humans during central hypovolemia is a determinant of AVP and renin release.


2016 ◽  
Vol 31 (suppl_1) ◽  
pp. i183-i183
Author(s):  
Maarten A de Jong ◽  
Arie M van Roon ◽  
Jens T Bakker ◽  
Wernard Kersten ◽  
Pieter W. Kamphuisen ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-10 ◽  
Author(s):  
Ramin Bighamian ◽  
Jin-Oh Hahn

Arterial pulse pressure has been widely used as surrogate of stroke volume, for example, in the guidance of fluid therapy. However, recent experimental investigations suggest that arterial pulse pressure is not linearly proportional to stroke volume. However, mechanisms underlying the relation between the two have not been clearly understood. The goal of this study was to elucidate how arterial pulse pressure and stroke volume respond to a perturbation in the left ventricular blood volume based on a systematic mathematical analysis. Both our mathematical analysis and experimental data showed that the relative change in arterial pulse pressure due to a left ventricular blood volume perturbation was consistently smaller than the corresponding relative change in stroke volume, due to the nonlinear left ventricular pressure-volume relation during diastole that reduces the sensitivity of arterial pulse pressure to perturbations in the left ventricular blood volume. Therefore, arterial pulse pressure must be used with care when used as surrogate of stroke volume in guiding fluid therapy.


Shock ◽  
2008 ◽  
Vol 30 (Suppl 1) ◽  
pp. 18-22 ◽  
Author(s):  
Jose Otavio C. Auler ◽  
Filomena R.B.G. Galas ◽  
Marcia R. Sundin ◽  
Ludhmila A. Hajjar

2007 ◽  
Vol 29 (6) ◽  
pp. 578-582 ◽  
Author(s):  
P. K. Eide ◽  
M. Czosnyka ◽  
W. Sorteberg ◽  
J. D. Pickard ◽  
P. Smielewski

Sign in / Sign up

Export Citation Format

Share Document