Does aerobic capacity predict the spatial position of individuals within schools in juvenile qingbo (Spinibarbus sinensis)?

Author(s):  
Ling-Qing Zeng ◽  
Cheng Fu ◽  
Shi-Jian Fu
Author(s):  
F. Seehofer ◽  
W. Schulz

AbstractThe phenomenon of the smoulder stream flowing through the cigarette during smouldering and during the puff intervals is demonstrated for the first time and its dependence upon physical conditions is examined. The volume of the smoulder stream can amount up to 180 ml per cigarette. Increasing draw resistance of the cigarette and augmenting moisture content of the tobacco as well as perforation of the cigarette paper have a decreasing effect on volume and velocity of the smoulder stream. The porosity of the cigarette paper has no perceptible influence. The spatial position of the cigarette affects volume and velocity of the smoulder stream. The influence exercised by the smoulder stream on the yields of total condensate, nicotine, phenols, aldehydes, and acroleine when the cigarette tip is open during the puff intervals is determined. When the moisture contents of the tobacco were extremely high, yield decreases reaching 50 % could be observed.


2020 ◽  
Vol 9 (3) ◽  
pp. 113-117
Author(s):  
Garett Griffith ◽  
Badeia Saed ◽  
Tracy Baynard

ABSTRACT Background: Multiple sclerosis (MS) is an autoimmune disease that impacts the central nervous system. MS generally results in decreased mobility and work capacity. Our objective was to determine exercise testing responses on both a treadmill and cycle ergometer among individuals with MS who were able to ambulate freely. Methods: Twenty-six individuals with MS participated in a cross-sectional study (44 ± 11 years; body mass index 26.8 ± 6.2 kg·m−2; expanded disability scale score 3.1 ± 0.9), with 24 individuals with complete test data for both treadmill and cycle ergometry tests. Peak aerobic capacity (VO2peak) for both treadmill and cycle ergometry tests were measured with indirect calorimetry. Results: Participants safely completed both treadmill and cycle ergometry tests, and treadmill testing yielded higher values (26.7 ± 6.4 mL·kg−1·min−1) compared with cycle ergometry (23.7 ± 5.7 mL·kg−1·min−1), with values ~12% greater for treadmill. When comparing tests to their respected predicted values within modality, treadmill tests were 8% lower and cycle ergometry tests were 10% lower than predicted. Conclusions: While peak aerobic capacity was very low for this population, treadmill tests were still higher than cycle ergometry data, with this difference between modes being similar to that observed in healthy adult populations. Additional research is required to determine if these findings are impacted by participation in physical activity or regular exercise.


Sign in / Sign up

Export Citation Format

Share Document