Stability of amino acids and acylcarnitines in dried blood spots stored at room temperature over a one-year period

2019 ◽  
Vol 493 ◽  
pp. S590-S591
Author(s):  
A. Cambra ◽  
B. Besga ◽  
A. Montero ◽  
M. González-Rivera ◽  
M.L. Ruano
2008 ◽  
Vol 54 (3) ◽  
pp. 542-549 ◽  
Author(s):  
Devin Oglesbee ◽  
Karen A Sanders ◽  
Jean M Lacey ◽  
Mark J Magera ◽  
Bruno Casetta ◽  
...  

Abstract Background: Newborn screening for maple syrup urine disease (MSUD) relies on finding increased concentrations of the branched-chain amino acids (BCAAs) leucine, isoleucine, and valine by tandem mass spectrometry (MS/MS). d-Alloisoleucine (allo-Ile) is the only pathognomonic marker of MSUD, but it cannot be identified by existing screening methods because it is not differentiated from isobaric amino acids. Furthermore, newborns receiving total parenteral nutrition often have increased concentrations of BCAAs. To improve the specificity of newborn screening for MSUD and to reduce the number of diet-related false-positive results, we developed a LC-MS/MS method for quantifying allo-Ile. Methods: Allo-Ile and other BCAAs were extracted from a 3/16-inch dried blood spot punch with methanol/H2O, dried under nitrogen, and reconstituted into mobile phase. Quantitative LC-MS/MS analysis of allo-Ile, its isomers, and isotopically labeled internal standards was achieved within 15 min. To determine a reference interval for BCAAs including allo-Ile, we analyzed 541 dried blood spots. We also measured allo-Ile in blinded samples from 16 MSUD patients and 21 controls and compared results to an HPLC method. Results: Intra- and interassay imprecision (mean CVs) for allo-Ile, leucine, isoleucine, and valine ranged from 1.8% to 7.4%, and recovery ranged from 91% to 129%. All 16 MSUD patients were correctly identified. Conclusions: The LC-MS/MS method can reliably measure allo-Ile in dried blood spots for the diagnosis of MSUD. Applied to newborn screening as a second-tier test, it will reduce false-positive results, which produce family anxiety and increase follow-up costs. The assay also appears suitable for use in monitoring treatment of MSUD patients.


Blood ◽  
2014 ◽  
Vol 124 (21) ◽  
pp. 4566-4566
Author(s):  
Olga Sala Torra ◽  
Lan Beppu ◽  
Susan Branford ◽  
Linda Fletcher ◽  
Gooley Ted ◽  
...  

Abstract In many parts of the world, diagnosis and monitoring of CML patients is limited by the availability and cost of molecular testing. In countries without molecular diagnostic capabilities, blood samples can be shipped to central labs, but this is both hampered by sample degradation, and the high costs of shipping. This study explores the method of directly spotting peripheral blood onto a paper template (dried blood spots), with subsequent shipping, RNA extraction, and BCR-ABL testing. Methods: Blood Spots and Shipment. We received dried blood spots from Australia and African countries by mail or courier, and blood from CML patients from our institution were also used for these experiments. 200μL of blood (PB) was pipetted onto Whatman 503 Protein Saver Cards (PSC; Sigma-Aldrich), where each card contains four 50μL spots. Cards were allowed to dry for at least 24 hours at room temperature. For mailing, PSCs were sealed into glassine envelopes with a packet of desiccant, and then placed inside a mailing envelope following DOT and IATA regulation for shipping non-regulated, exempt human specimens. RNA Extraction from Cards and %BCR-ABL determination. Blood spots were incubated with proteinase K followed by RNA isolation using RNeasy Mini Kits (Qiagen). Extracted RNA was quantified using a NanoDrop spectrometer (Thermo Scientific). %BCR-ABL was determined using the automated Cepheid GeneXpert platform or manual two-step quantitative RT-PCR on the 7900HT Fast Real-Time PCR System (Applied Biosystems). Results: Bench top time course: To test for effects of long transit times on RNA quality, we performed a time course study of cards at room temperature (RT) with 5 samples. For each sample, multiple cards were spotted with PB. The cards were then allowed to sit at RT for predetermined amounts of time, up to 42 days, before extracting RNA. We measured RNA integrity for one of the specimens (CML # 5) and found rapid degradation with the RIN number going from 8.7 for the fresh blood to 2.8 after 28 days on the card. However the amplification for both BCR-ABL and ABL differed less than one cycle between the fresh blood and the last time point by manual qRT-PCR (BCR-ABL Ct = 23.63 for fresh blood and 24.06 for day 28 PSC; ABL Ct = 26.69 for fresh blood and 27.64 for day 28 PSC). Figure 1 shows the results of the time course experiment for the 5 samples as a plot of ΔCt versus time in days. BCR-ABL qRT-PCR concordance studies: We compared the %BCR-ABL results obtained in fresh specimen at the institution sending the sample with the %BCR-ABL results we obtained from RNA extracted from PSC using the Cepheid GeneXpert. Paired evaluable results were available for 9 samples with a median WBC = 9.8 x 109/L (range: 3.37x109/L – 85.5x109/L). Samples were 8 to 49 days old at the time of extraction. The amount of RNA input into the GeneXpert reaction ranged from 38.75ng to 1μg. The %BCR-ABL detected ranged from 0.37% to 27% (see Table). The mean absolute difference between fresh blood and PSC BCR-ABL% is 2%; the relative mean percent change for BCR-ABL, using fresh blood as the reference is 13.1% (S.D., 31.2), P = 0.24. Conclusions and future directions: Dried blood spots are relatively inexpensive method to transport blood that preserves enough RNA stability to allow highly accurate BCR-ABL detection, when compared to results performed on an identical platform using fresh peripheral blood samples. Further studies are undergoing to accurately determine the sensitivity of this method and the feasibility of using regular mail for inexpensive transport of specimens. Table 1IDWBC (1000/μL)Sample Age at Spotting (Days)Sample Age at RNA extraction (Days)RNA ng/μlVolume GeneXPert (μL)Paper %BCR-ABL (IS)GeneXpertFresh Blood % BCR-ABL (IS) GeneXpertI1na010426349naI224.101311092745I38009181544naI47.4285102.4*3.1I55.50495241.92I63.61307.4225912I785.5130102102439I812.212912.415128.8I9na1281.5250.37*0.71I103.370273257.85.7I1115.912731102325I126.612714.415na2.3 *%BCR-ABL was manually calculated due to late ABL Cts because of low starting material. Figure 1 Figure 1. Disclosures No relevant conflicts of interest to declare.


2008 ◽  
Vol 54 (4) ◽  
pp. 657-664 ◽  
Author(s):  
Coleman Turgeon ◽  
Mark J Magera ◽  
Pierre Allard ◽  
Silvia Tortorelli ◽  
Dimitar Gavrilov ◽  
...  

Abstract Background: Tyrosinemia type I (TYR 1) is a disorder causing early death if left untreated. Newborn screening (NBS) for this condition is problematic because determination of the diagnostic marker, succinylacetone (SUAC), requires a separate first-tier or only partially effective second-tier analysis based on tyrosine concentration. To overcome these problems, we developed a new assay that simultaneously determines acylcarnitines (AC), amino acids (AA), and SUAC in dried blood spots (DBS) by flow injection tandem mass spectrometry (MS/MS). Methods: We extracted 3/16-inch DBS punches with 300 μL methanol containing AA and AC stable isotope-labeled internal standards. This extract was derivatized with butanol-HCl. In parallel, we extracted SUAC from the residual filter paper with 100 μL of a 15 mmol/L hydrazine solution containing the internal standard 13C5-SUAC. We combined the derivatized aliquots in acetonitrile for MS/MS analysis of AC and AA with additional SRM experiments for SUAC (m/z 155–137) and 13C5-SUAC (m/z 160–142). Analysis time was 1.2 min. Results: SUAC was increased in retrospectively analyzed NBS samples of 11 TYR 1 patients (length of storage, 52 months to 1 week; SUAC range, 13–81 μmol/L), with Tyr concentrations ranging from 65 to 293 μmol/L in the original NBS analysis. The mean concentration of SUAC in 13 521 control DBS was 1.25 μmol/L. Conclusion: The inclusion of SUAC analysis into routine analysis of AC and AA allows for rapid and cost-effective screening for TYR 1 with no tangible risk of false-negative results.


2011 ◽  
Vol 412 (15-16) ◽  
pp. 1385-1390 ◽  
Author(s):  
Donald H. Chace ◽  
Víctor R. De Jesús ◽  
Timothy H. Lim ◽  
W. Harry Hannon ◽  
Reese H. Clark ◽  
...  

1999 ◽  
Vol 45 (8) ◽  
pp. 1269-1277 ◽  
Author(s):  
Donald H Chace ◽  
Barbara W Adam ◽  
S Jay Smith ◽  
J Richard Alexander ◽  
Steven L Hillman ◽  
...  

Abstract Background: Advances in technology and the earlier release of newborns from hospitals have pressed the demand for accurate calibration and improved interlaboratory performance for newborn screening tests. As a first step toward standardization of newborn screening aminoacidopathy tests, we have produced six-pool sets of multianalyte dried-blood-spot amino acid reference materials (AARMs) containing predetermined quantities of five amino acids. We describe here the production of the AARMs, validation of their amino acid contents, and characterization of their homogeneity and their stability in storage. Methods: To each of six portions of a pool of washed erythrocytes suspended in serum we added Phe (0–200 mg/L), Leu (0–200 mg/L), Met (0–125 mg/L), Tyr (0–125 mg/L), and Val (0–125 mg/L). Six-pool sets (1300) were prepared, dried, and packaged. We used isotope-dilution mass spectrometry to estimate the endogenous amino acid concentrations of the AARMs and validate their final amino acid concentrations. We used additional tandem mass spectrometry analyses to examine the homogeneity of amino acid distribution in each AARM, and HPLC analyses to evaluate the stability of the amino acid contents of the AARMs. Results: The absolute mean biases across the analytic range for five amino acids were 2.8–9.4%. One-way ANOVAs of the homogeneity results predicted no statistically significant differences in amino acid concentrations within the blood spots or within the pools (P >0.05). Regression slopes (0 ± 0.01) for amino acid concentrations vs storage times and their P values (>0.05) showed no evidence of amino acid degradation at ambient temperatures, 4 °C, or −20 °C during the intervals tested. Conclusion: The validation, homogeneity, and stability of these blood spots support their use as a candidate national reference material for calibration of assays that measure amino acids in dried-blood spots.


2018 ◽  
Vol 34 (12) ◽  
pp. 1013-1016
Author(s):  
Anna L. Eisenberg ◽  
Eshan U. Patel ◽  
Zoe R. Packman ◽  
Reinaldo E. Fernandez ◽  
Estelle Piwowar-Manning ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document