Experimental results and modeling of boiling heat transfer coefficients in falling film evaporator usable for evaporator design

2009 ◽  
Vol 48 (4) ◽  
pp. 961-968 ◽  
Author(s):  
Tarif Ali Adib ◽  
Bertrand Heyd ◽  
Jean Vasseur
2019 ◽  
Vol 141 (7) ◽  
Author(s):  
J. A. Hernández-Magallanes ◽  
W. Rivera

This paper reports the experimental data of boiling heat transfer coefficients for the ammonia–lithium nitrate mixture in a laminar falling film. The analyzed heat exchanger consists of a shell with an internal helical coil. More than one hundred test runs were carried out in steady-state conditions to determine the boiling heat transfer coefficients at generation temperatures, concentrations, and mass flow rates typical of absorption cooling systems of capacities between 5 and 10 kW. Ammonia vapor was produced at generation temperatures between 80 °C and 105 °C obtaining boiling heat transfer coefficients between 85 and 340 W/m2K. Semi-empirical correlations were used by diverse authors to correlate the experimental data. A new correlation was proposed with which the best adjustments were obtained. Also, the influence of the heat flux, the refrigerant solution mass flow rates, and the exit vapor qualities were analyzed in the boiling heat transfer coefficients.


2017 ◽  
Vol 139 (10) ◽  
Author(s):  
Jinsub Kim ◽  
Seongchul Jun ◽  
Jungho Lee ◽  
Juan Godinez ◽  
Seung M. You

The effect of surface roughness on the pool boiling heat transfer of water was investigated on superhydrophilic aluminum surfaces. The formation of nanoscale protrusions on the aluminum surface was confirmed after immersing it in boiling water, which modified surface wettability to form a superhydrophilic surface. The effect of surface roughness was examined at different average roughness (Ra) values ranging from 0.11 to 2.93 μm. The boiling heat transfer coefficients increased with an increase in roughness owing to the increased number of cavities. However, the superhydrophilic aluminum surfaces exhibited degradation of the heat transfer coefficients when compared with copper surfaces owing to the flooding of promising cavities. The superhydrophilic aluminum surfaces exhibited a higher critical heat flux (CHF) than the copper surfaces. The CHF was 1650 kW/m2 for Ra = 0.11 μm, and it increased to 2150 kW/m2 for Ra = 0.35 μm. Surface roughness is considered to affect CHF as it improves the capillary wicking on the superhydrophilic surface. However, further increase in surface roughness above 0.35 μm did not augment the CHF, even at Ra = 2.93 μm. This upper limit of the CHF appears to result from the hydrodynamic limit on the superhydrophilic surface, because the roughest surface with Ra = 2.93 μm still showed a faster liquid spreading speed.


2016 ◽  
Vol 138 (8) ◽  
Author(s):  
Cong Qi ◽  
Yongliang Wan ◽  
Lin Liang ◽  
Zhonghao Rao ◽  
Yimin Li

Considering mass transfer and energy transfer between liquid phase and vapor phase, a mixture model for boiling heat transfer of nanofluid is established. In addition, an experimental installation of boiling heat transfer is built. The boiling heat transfer of TiO2–water nanofluid is investigated by numerical and experimental methods, respectively. Thermal conductivity, viscosity, and boiling bubble size of TiO2–water nanofluid are experimentally investigated, and the effects of different nanoparticle mass fractions, bubble sizes and superheat on boiling heat transfer are also discussed. It is found that the boiling bubble size in TiO2–water nanofluid is only one-third of that in de-ionized water. It is also found that there is a critical nanoparticle mass fraction (wt.% = 2%) between enhancement and degradation for TiO2–water nanofluid. Compared with water, nanofluid enhances the boiling heat transfer coefficient by 77.7% when the nanoparticle mass fraction is lower than 2%, while it reduces the boiling heat transfer by 30.3% when the nanoparticle mass fraction is higher than 2%. The boiling heat transfer coefficients increase with the superheat for water and nanofluid. A mathematic correlation between heat flux and superheat is obtained in this paper.


Author(s):  
Todd M. Bandhauer ◽  
Taylor A. Bevis

The principle limit for achieving higher brightness of laser diode arrays is thermal management. State of the art laser diodes generate heat at fluxes in excess of 1 kW cm−2 on a plane parallel to the light emitting edge. As the laser diode bars are packed closer together, it becomes increasingly difficult to remove large amounts of heat in the diminishing space between neighboring diode bars. Thermal management of these diode arrays using conduction and natural convection is practically impossible, and, therefore, some form of forced convective cooling must be utilized. Cooling large arrays of laser diodes using single-phase convection heat transfer has been investigated for more than two decades by multiple investigators. Unfortunately, either large fluid temperature increases or very high flow velocities must be utilized to reject heat to a single phase fluid, and the practical threshold for single phase convective cooling of laser diodes appears to have been reached. In contrast, liquid-vapor phase change heat transport can occur with a negligible increase in temperature and, due to a high enthalpy of vaporization, at comparatively low mass flow rates. However, there have been no prior investigations at the conditions required for high brightness edge emitting laser diode arrays: >1 kW cm−2 and >10 kW cm−3. In the current investigation, flow boiling heat transfer at heat fluxes up to 1.1 kW cm−2 was studied in a microchannel heat sink with plurality of very small channels (45 × 200 microns) using R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio in the vicinity of the laser diode. To characterize the heat transfer performance, a test facility was constructed that enabled testing over a range of fluid saturation temperatures (15°C to 25°C). Due to the very small geometric features, significant heat spreading was observed, necessitating numerical methods to determine the average heat transfer coefficient from test data. This technique is crucial to accurately calculate the heat transfer coefficients for the current investigation, and it is shown that the analytical approach used by many previous investigations requires assumptions that are inadequate for the very small dimensions and heat fluxes observed in the present study. During the tests, the calculated outlet vapor quality exceeded 0.6 and the base heat flux reached a maximum of 1.1 kW cm−2. The resulting experimental heat transfer coefficients are found to be as large a 58.1 kW m−2 K−1 with an average uncertainty of ±11.1%, which includes uncertainty from all measured and calculated values, required assumptions, and geometric discretization error from meshing.


2006 ◽  
Vol 10 (4) ◽  
pp. 55-61 ◽  
Author(s):  
Zoltan Zavargo ◽  
Aleksandar Jokic ◽  
Bojana Prodanic ◽  
Jasna Grbic ◽  
Rada Jeftic-Mucibabic

General trend of free trade in regional level as well as in the direction of European Union has motivated sugar factories located in Serbia to invest into technologies that are more efficient in order to make their products more competitive at the markets in Europe. The aim of this work was to evaluate effects of falling film plate evaporators on the energy consumption of evaporation plant, as well as to validate performance of this type of evaporators. It was found that this type of evaporator decreased energy requirements and in the same time evaporation process was more effective due to high values of heat transfer coefficients. .