Corrosion resistance and photocatalytic activity evaluation of electrophoretically deposited TiO2-rGO nanocomposite on 316L stainless steel substrate

2019 ◽  
Vol 45 (11) ◽  
pp. 13747-13760
Author(s):  
Maryam Azadeh ◽  
Sahar Parvizy ◽  
Abdollah Afshar
Coatings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 622
Author(s):  
Xiaolong Xie ◽  
Bingbing Yin ◽  
Fucheng Yin ◽  
Xuemei Ouyang

The corrosion of galvanizing equipment parts by liquid zinc is an urgent problem that needs solving. In this work, FeB-30 wt.% Al0.25FeNiCoCr cermet coating was deposited on the surface of 316L stainless steel by AC-HVAF to protect galvanizing equipment parts from corrosion by liquid zinc. The microstructures and phase compositions of powders and the coating were determined by SEM, EDS, and XRD in detail. Additionally, the microhardness, fracture toughness, abrasion wear resistance, and corrosion resistance of the coating to liquid zinc were also studied. The results indicate that the abrasion wear resistance and corrosion resistance of the coating are much better than that of the 316L stainless steel substrate. The failure of the coating in liquid zinc is mainly due to the penetration of liquid zinc into macro-cracks, which causes the coating to peel off.


Metals ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1104
Author(s):  
Zexu Du ◽  
Zhengfei Hu ◽  
Yuqiang Feng ◽  
Fan Mo

Two kinds of 60NiTi powders were prepared by pure Ni mixed with Ti powders, and 55NiTi alloy powder with pure Ni powder and both the powders were fully mixed by alcohol ball milling. Two kinds of coatings (denoted as 60Ni-40Ti and 55NiTi-5Ni) were prepared on a 316L stainless steel substrate by laser cladding. The microstructure, microhardness and electrochemical behavior of the prepared coatings were investigated extensively. The results show that 55NiTi-5Ni has a typical dendritic eutectic structure, but 60Ni-40Ti tends to form a eutectic network structure. The main phases in both coatings are (Ni, Fe)Ti and (Ni, Fe)3Ti; however, the (Ni, Fe)Ti phase is dominant in 55NiTi-5Ni, but the (Ni, Fe)3Ti phase is more prevalent in 60Ni-40Ti. The microhardness was significantly improved with the 316L stainless steel substrate, and the microhardness of 55NiTi-5Ni is slightly higher than 60Ni-40Ti. The corrosion resistance of the two coatings in 3.5 wt% NaCl solution also leads to significant improvements compared with the substrate, and the corrosion resistance of 55NiTi-5Ni was also increased. These different behaviors and characteristics might be related to the different microstructures. Uniform and fine eutectic structure in 55NiTi-5Ni coating lead to better performance, which is also conducive to the formation of the dense oxide film to improve corrosion resistance.


2010 ◽  
Vol 148-149 ◽  
pp. 740-743
Author(s):  
Wei Yan Liu ◽  
Xiu Yan Li ◽  
He Feng Wang ◽  
Rui Feng ◽  
Bin Tang

Titanium surface alloyed layer was fabricated on 316L stainless steel substrate at 1000°C by means of the plasma surface alloying technique. The content of element titanium in the surface alloyed layer shows gradually tapering from surface to the inside of the substrate and it means an excellent metallurgical binding between the surface modified layer and 316L stainless steel substrate. The hardness of the titanium surface alloyed Layer is 1305HK0.5, which is much larger than that of the 316L stainless steel substrate. The wear performance of the treated and untreated 316L stainless steel was studied using a ball-on-disc sliding wear machine. Although the titanium surface alloyed layer does not show a friction-reducing effect, it improves the wear resistance of 316L stainless steel significantly and its wear rate is only one-fifteenth of that for untreated 316L stainless steel.


Coatings ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 963
Author(s):  
Di Pei ◽  
Li Wang ◽  
Ming-hui Ding ◽  
Zhao-nan Hu ◽  
Jun-yu Zhao ◽  
...  

In the paper, by using radio frequency (RF) magnetron sputter technology, the HfC coating grew on a 316L stainless steel substrate in an Ar atmosphere at various substrate bias voltages from 0 to −200 V. From the X-ray diffraction (XRD) and transmission electron microscopy (TEM) experiments, the HfC coatings were well crystallized and (111) preferential growth had been successfully obtained by controlling bias voltage at −200 V. Nanoindentation experimental results for the prepared HfC coatings indicated that they possessed the maximum nanohardness due to the formation of the (111) orientation. The results of electrochemical measurements displayed that 316L stainless steel (316L) coated with the HfC coatings had better corrosion resistance than bare 316L. With the bias voltage increasing to −200 V, adhesion of the 316L substrate with the HfC coating could be greatly improved, as well as corrosion resistance. The antithrombogenicity of the HfC coatings was identified by platelet adhesive and hemolytic ratio assay in vitro. It was shown that the hemocompatibility of coated 316L had been improved greatly compared with bare 316L and the HfC coatings possessed better antithrombogenicity with the bias voltage elevating above −150 V.


2009 ◽  
Vol 23 (06n07) ◽  
pp. 1047-1052 ◽  
Author(s):  
YUJIANG WANG ◽  
XINXIN MA ◽  
GUANGZE TANG

The micro-pores with size of 0.2 to 1.8 µm, which randomly distribute in a 316L stainless steel substrate, were fabricated by the transfer of the porous structure of anodic porous alumina. The mask anodic porous alumina was directly prepared by anodizing of aluminum film, which was deposited on 316L substrate by DC magnetron sputtering. The transfer of the porous structure of anodic alumina into the 316L substrate could be achieved without the additional through-hole treatment to the barrier layer. The localized priority dissolution on porous alumina is observed during the anodizing. And this process is considered to lead to the micro-pores formation on 316L substrate. In addition, the effect of anodizing time on the pores size and number on 316L substrate also was discussed.


2009 ◽  
Vol 419-420 ◽  
pp. 537-540
Author(s):  
Ming Hui Ding ◽  
Ben Li Wang ◽  
Li Li ◽  
Yu Feng Zheng

In this paper, the TaCx coating with thickness around 1.2 μm was prepared by radio frequency magnetron sputtering technique on the 316L stainless steel substrate to improve its hemocompatibility. The structure and morphology of the coating were characterized by XRD and SEM. The XRD results indicated that TaCx, as a new species, appeared on the surface of the 316L stainless steel substrate. SEM images showed that the surface morphology of the TaCx coating was uniform and dense. The mechanical characteristics of the coating were measured by nanoindentation, giving a nanohardness of 13 GPa and a Young’s modulus of 210 GPa. The adhesion strength of the TaCx coating to 316L stainless steel depended on the sputtering bias voltages and increased for a higher bias voltage. The hemocompatibility of the TaCx coating, as evaluated by platelet adhesion tests, was compared to that of the bare 316L stainless steel. The results indicated that the hemocompatibility of 316L stainless steel with TaCx coating was significantly improved as compared to the original one.


Sign in / Sign up

Export Citation Format

Share Document