scholarly journals Analytical performance of the Xpert MTB/XDR® assay for tuberculosis and expanded resistance detection

Author(s):  
Sophia B Georghiou ◽  
Adam Penn-Nicholson ◽  
Margaretha de Vos ◽  
Aurélien Macé ◽  
Melanie W Syrmis ◽  
...  
2018 ◽  
Vol 8 (2) ◽  
pp. 62
Author(s):  
Kwang-Sook Woo ◽  
Gyu-Dae An ◽  
Hyeon-Ho Lim ◽  
Jin-Yeong Han

2020 ◽  
Vol 154 (Supplement_1) ◽  
pp. S12-S13
Author(s):  
Nga Yeung Tang ◽  
Sarosh Rana ◽  
Kiang-Teck J Yeo

Abstract Background Preeclampsia is a leading hypertensive disorder in pregnant women. The angiogenic biomarkers, soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF) ratio, have been shown to be associated with diagnosis and prediction of preeclampsia. The objective of this study is to validate the analytical performance of sFlt-1 and PlGF on the Cobas e602 system (Roche Diagnostics Corporation). Method Intra-day and inter-day precisions for both sFlt-1 and PlGF assays were assessed using quality control materials provided from Roche Diagnostics. The accuracies for both assays were assessed by running 60 patient samples, which have been previously analyzed on the Elecsys 411 analyzer (Roche Diagnostics Corporation) at the Beth Israel Deaconess Medical Center. Linearity studies for both assays were performed using patient plasma spiked with recombinant sFlt-1 and PlGF proteins (R&D systems). Hemolysis, icterus, lipemia and biotin interference studies were performed by spiking hemolysate, bilirubin, intralipid or biotin into either pooled patient plasma with detectable levels of sFlt-1 and PlGF or otherwise, patient plasma spiked with recombinant sFlt-1 and PlGF proteins. Results Total precisions for both assays demonstrated CVs of <5.0%. The sFlt-1 and PlGF assays demonstrated analytical measuring ranges of 3060,000 pg/mL and 79,000 pg/mL, respectively (r2 > 0.98). Lower limit of quantitation (10% CV) was 30 pg/mL for sFlt-1 and 7 pg/mL for PlGF, respectively. Interference studies showed sFlt-1 and PlGF were not significantly affected by hemolysis up to H-indices of 500 and 1000 respectively; both assays were not affected by bilirubin up to an I-index of 60, and lipemia up to an L-index of 2800. Biotin at concentrations >30 ng/mL caused significant negative bias for both sFlt-1 and PlGF assays. Comparison studies showed the following: Cobas e602 sFLT-1 = 1.09 [Elecsys 411 sFLT-1] +203 (r2=0.97, Sy/x=1234, n=58); Cobas e602 PlGF = 1.10 [Elecsys 411 PlGF] +47 (r2=0.99, Sy/x=22.1, n=58); Cobas e602 sFLT-1/PlGF ratio = 0.94 [Elecsys 411 sFLT-1/PlGF ratio] +3.5 (r2=0.91, Sy/x=50, n=58). Conclusion sFlt-1 and PlGF measured on Roche Diagnostics Cobas e602 system demonstrated excellent analytical performance and are acceptable for clinical use once approved in the US.


2021 ◽  
pp. 113043
Author(s):  
Marnix Mylemans ◽  
Eveline Van Honacker ◽  
Louis Nevejan ◽  
Stefanie van den Bremt ◽  
Laura Hofman ◽  
...  

2020 ◽  
Vol 7 (12) ◽  
Author(s):  
Serge Tonen-Wolyec ◽  
Jérémie Muwonga Masidi ◽  
Luc Ferdinand Kamanga Lukusa ◽  
Gaetan Nsiku Dikumbwa ◽  
Angèle Sarassoro ◽  
...  

Abstract The Democratic Republic of the Congo (DRC) has begun implementing HIV self-testing to boost the first “95” of the UNAIDS 95-95-95 targets by 2025. This study aims to assess the performance and usability of the Exacto Test HIV (Biosynex, Strasbourg, France) self-test in the lab and in the field. The Exacto Test HIV self-test demonstrated high virological performance (sensitivity, 99.6%; specificity, 100%) in the lab and in the field in the hand of untrained users (sensitivity, 100%; specificity, 98.9%). Taken together, the excellent performance and usability characteristics of the Exacto Test HIV (Biosynex) self-test make the kit a viable option for HIV self-testing in the DRC.


Author(s):  
Carmen Perich ◽  
Carmen Ricós ◽  
Fernando Marqués ◽  
Joana Minchinela ◽  
Angel Salas ◽  
...  

AbstractThe purpose of this study is to understand the evolution of the analytical performance of the laboratories participating in the Spanish society of laboratory medicine (SEQCML) external quality assurance (EQA) programmes during its 30 years of operation and to compare it with the performance of other EQA programmes to establish whether the results are similar. The results obtained during this period are evaluated by applying the biological variability (BV) and state of the art-derived quality specifications. In addition, the results are compared with those obtained by other EQA programme organisations. It is noted that the laboratories participating in the EQA–SEQCML programmes have improved their performance over 30 years of experience and that the specifications derived from biological variation are achievable. It is difficult to compare EQA programmes, due to lack of accessibility and the differences in the design of these programmes (control materials, calculations used and analytical specifications established). The data from this study show that for some biological magnitudes the results obtained by the programmes are not yet harmonised, although efforts are being made to achieve this. Organisers of EQA programmes should also join the harmonisation effort by providing information on their results to enable comparison.