scholarly journals Effect of the occupant and the inside faces coating of a multi-alveolar structure on the unsteady thermal behavior of a bi-zone building

2017 ◽  
Vol 139 ◽  
pp. 550-557
Author(s):  
Nour Lajimi ◽  
Nour Ben Taher ◽  
Noureddine Boukadida
2015 ◽  
Vol 19 (3) ◽  
pp. 929-938
Author(s):  
Nour Lajimi ◽  
Noureddine Boukadida

This paper presents a numerical study of local thermal behavior. Vertical walls are equipped with alveolar structure and/or simple glazing in East, South and West frontages. Local temperature is assumed to be variable with time or imposed at set point temperature. Results principally show that the simple glazing number has a sensitive effect on convection heat transfer and interior air temperature. They also show that the diode effect is more sensitive in winter. The effect of alveolar structure and simple glazing on the power heating in case with set point temperature is also brought out.


2019 ◽  
Vol 13 ◽  
pp. 670-678
Author(s):  
M. Boukendil ◽  
B. Jamal ◽  
A. Abdelbaki ◽  
Z. Zrikem

Author(s):  
Nour Lajimi ◽  
Nour Ben Taher ◽  
Noureddine Boukadida

Abstract The study of the thermal inertia of buildings is a subject of major interest. The thermal insulation and the nature of the wall sensitively modify the inertia of the building and are the solutions to improve the energy efficiency of the envelope. The roof is well exposed to solar radiation in summer and contributes to significant losses in winter due to convective exchanges. To lead to a thermal comfort, a thermal insulation is necessary. In this context, we carry out a numerical study of the thermal behavior of a building with two zones in variable meteorological conditions for a Tunisian climate (region of Sousse) based on the thermoelectric analogy and using the nodal method as a numerical method. The object of this work is to study the effect of the thermal inertia of the roof equipped with a multi-alveolar structure on the thermal behavior of the air inside the room and on its energy consumption. Taking into account the energy input of occupant, a complete model was established to increase the accuracy of the calculations. The results show that the multi-alveolar structure placed on the outside of the roof reduces energy consumption during the winter period when the alveolar structure is placed in the conductive direction and during the summer period when the alveolar structure is placed in the insulate direction.


2020 ◽  
Vol 40 (suppl 2) ◽  
pp. 597-604
Author(s):  
Zahra NILCHIAN ◽  
Mohamad Reza EHSANI ◽  
Zahra PIRAVI-VANAK ◽  
Hossein BAKHODA

2019 ◽  
Vol 50 (17) ◽  
pp. 1721-1736
Author(s):  
Kaiqiang Hou ◽  
Xiaolong Weng ◽  
Wei Luo ◽  
Le Yuan ◽  
Wei Duan ◽  
...  

2011 ◽  
Vol 7 (2) ◽  
pp. 1338-1347
Author(s):  
Tarek Ali Fahad ◽  
Shaker.A.N. AL-Jadaan

Two new heterocyclic Organmercury compounds   were prepared from the reaction of Sulfamethaxazole and Sulfadiazine with 4-acetaminophenol as a coupler and separated as solids with characteristic colors. these compounds were characterized by F.T.IR-spectroscopy 1H-NMR , Micro-elemental Analysis and UV-Vis spectroscopic techniques . The work involves a study of acid – base properties compounds at different pH values, the ionization and protonation constants were calculated. The thermal behavior of these two compounds   were investigated on the basis of thermogravimetric (TGA) and differential thermogravimetric (DTG) analyses, Thermal decomposition of these compounds is multi-stage processes.


Sign in / Sign up

Export Citation Format

Share Document