scholarly journals Interval optimization based coordination scheduling of gas–electricity coupled system considering wind power uncertainty, dynamic process of natural gas flow and demand response management

2020 ◽  
Vol 6 ◽  
pp. 216-227 ◽  
Author(s):  
Yachao Zhang ◽  
Zhanghao Huang ◽  
Feng Zheng ◽  
Rongyu Zhou ◽  
Xueli An ◽  
...  
1989 ◽  
Vol 111 (1) ◽  
pp. 22-33
Author(s):  
V. C. Ting ◽  
J. J. S. Shen

This paper presents the orifice calibration results for nominal 15.24, 10.16, and 5.08-cm (6, 4, 2-in.) orifice meters conducted at the Chevron’s Sand Hills natural gas flow measurement facility in Crane, Texas. Over 200 test runs were collected in a field environment to study the accuracy of the orifice meters. Data were obtained at beta ratios ranging from 0.12 to 0.74 at the nominal conditions of 4576 kPa and 27°C (650 psig and 80°F) with a 0.57 specific gravity processed, pipeline quality natural gas. A bank of critical flow nozzles was used as the flow rate proving device to calibrate the orifice meters. Orifice discharge coefficients were computed with ANSI/API 2530-1985 (AGA3) and ISO 5167/ASME MFC-3M-1984 equations for every set of data points. The uncertainty of the calibration system was analyzed according to The American National Standard (ANSI/ASME MFC-2M-A1983). The 10.16 and 5.08-cm (4 and 2-in.) orifice discharge coefficients agreed with the ANSI and ISO standards within the estimated uncertainty level. However, the 15.24-cm (6-in.) meter deviated up to − 2 percent at a beta ratio of 0.74. With the orifice bore Reynolds numbers ranging from 1 to 9 million, the Sand Hills calibration data bridge the gap between the Ohio State water data at low Reynolds numbers and Chevron’s high Reynolds number test data taken at a larger test facility in Venice, Louisiana. The test results also successfully demonstrated that orifice meters can be accurately proved with critical flow nozzles under realistic field conditions.


Energy Policy ◽  
2017 ◽  
Vol 106 ◽  
pp. 288-297 ◽  
Author(s):  
Maaike C. Bouwmeester ◽  
J. Oosterhaven

2013 ◽  
Vol 15 ◽  
pp. 27-37 ◽  
Author(s):  
Mahmood Farzaneh-Gord ◽  
Hamid Reza Rahbari ◽  
Mahdi Bajelan ◽  
Lila Pilehvari

Author(s):  
Nataliia Fialko ◽  
◽  
Julii Sherenkovskiy ◽  
Nataliia Meranova ◽  
Serhii Aloshko ◽  
...  

For microjet burners of the stabilizer type, a study of the regularities of the natural gas flow in the inner cavity of the flame stabilizer has been carried out. A comparative analysis of the features of heat transfer from the inner surfaces of the stabilizer walls is carried out for two variants of its configuration: flat and in the presence of trapezoidal niches on its lateral surfaces.


2011 ◽  
Vol 31 (14-15) ◽  
pp. 2605-2615 ◽  
Author(s):  
Hee Bum Lee ◽  
Bum Jin Park ◽  
Shin Hyung Rhee ◽  
Jun Hong Bae ◽  
Kyung Won Lee ◽  
...  

2014 ◽  
Vol 29 (4) ◽  
pp. 1780-1787 ◽  
Author(s):  
Carlos M. Correa-Posada ◽  
Pedro Sanchez-Martin

Sign in / Sign up

Export Citation Format

Share Document