Nosocomial outbreak by imipenem-resistant metallo-β-lactamase-producing Pseudomonas aeruginosa in an adult intensive care unit in a Brazilian teaching hospital

2009 ◽  
Vol 27 (5) ◽  
pp. 269-274 ◽  
Author(s):  
Renata Cristina Cezário ◽  
Lea Duarte De Morais ◽  
Joseane Cristina Ferreira ◽  
Rogério M. Costa-Pinto ◽  
Ana Lúcia da Costa Darini ◽  
...  
2016 ◽  
Vol 111 (9) ◽  
pp. 551-558 ◽  
Author(s):  
Luciana Camila Cacci ◽  
Stephanie Gomes Chuster ◽  
Natacha Martins ◽  
Pâmella Rodrigues do Carmo ◽  
Valéria Brígido de Carvalho Girão ◽  
...  

2007 ◽  
Vol 29 ◽  
pp. S347
Author(s):  
J. Garbino ◽  
P. Rohner ◽  
V. Alencar Nobre ◽  
N. Vernaz ◽  
C. Garzoni ◽  
...  

Author(s):  
Ana C. Gales ◽  
Patrícia L. Torres ◽  
Dominique S. O. Vilarinho ◽  
Renata S. Melo ◽  
Claudinéia F. L. Silva ◽  
...  

Critical Care ◽  
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Gaud Catho ◽  
R. Martischang ◽  
F. Boroli ◽  
M. N. Chraïti ◽  
Y. Martin ◽  
...  

Abstract Background Long-term outbreaks of multidrug-resistant Gram-negative bacilli related to hospital-building water systems have been described. However, successful mitigation strategies have rarely been reported. In particular, environmental disinfection or replacement of contaminated equipment usually failed to eradicate environmental sources of Pseudomonas aeruginosa. Methods We report the investigation and termination of an outbreak of P. aeruginosa producing VIM carbapenemase (PA-VIM) in the adult intensive care unit (ICU) of a Swiss tertiary care hospital with active case finding, environmental sampling and whole genome sequencing (WGS) of patient and environmental strains. We also describe the implemented control strategies and their effectiveness on eradication of the environmental reservoir. Results Between April 2018 and September 2020, 21 patients became either infected or colonized with a PA-VIM strain. For 16 of them, an acquisition in the ICU was suspected. Among 131 environmental samples collected in the ICU, 13 grew PA-VIM in sink traps and drains. WGS confirmed the epidemiological link between clinical and environmental strains and the monoclonal pattern of the outbreak. After removing sinks from patient rooms and implementation of waterless patient care, no new acquisition was detected in the ICU within 8 months after the intervention. Discussion Implementation of waterless patient care with removal of the sinks in patient rooms was successful for termination of a PA-VIM ICU outbreak linked to multiple environmental water sources. WGS provides highly discriminatory accuracy to investigate environment-related outbreaks.


2016 ◽  
Vol 73 (11_Supplement_3) ◽  
pp. S100-S105 ◽  
Author(s):  
Patrick M. Schmees ◽  
Scott J. Bergman ◽  
Brandi D. Strader ◽  
Megan E. Metzke ◽  
Sarah Pointer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document