scholarly journals Novel radiation-adjustable heating terminal based on flat heat pipe combined with air source heat pump

Engineering ◽  
2022 ◽  
Author(s):  
Yifan Wu ◽  
Hongli Sun ◽  
Mengfan Duan ◽  
Borong Lin ◽  
Hengxin Zhao ◽  
...  
2012 ◽  
Vol 170-173 ◽  
pp. 2723-2726 ◽  
Author(s):  
Jia You Liu

Coal mine drainage, exhaust air and bathing wastewater, etc. contain a large amount of waste heat resource. Using the waste heat effectively is beneficial to achieve energy conservation and emissions reduction and improve economic benefit for coal mine. Heat pump and heat pipe are thermal devices recycling waste heat effectively. The ways and purpose of recycling waste heat in coal mine by using water-source heat pump, air-source heat pump and heat pipe exchanger is given. The performance of heat pump and heat pipe is briefly evaluated.


2020 ◽  
Vol 180 ◽  
pp. 107029
Author(s):  
Pin Wu ◽  
Zhichao Wang ◽  
Xiaofeng Li ◽  
Zhaowei Xu ◽  
Yingxia Yang ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1321
Author(s):  
Yu-Jin Hwang ◽  
Jae-Weon Jeong

The objective of this research is to establish an appropriate operating strategy for a radiant floor heating system that additionally has an air source heat pump for providing convective air heating separately, leading to heating energy saving and thermal comfort in residential buildings. To determine the appropriate optimal operating ratio of each system taking charge of combined heating systems, the energy consumption of the entire system was drawn, and the adaptive floor surface temperature was reviewed based on international standards and literature on thermal comfort. For processing heating loads with radiant floor heating and air source heating systems, the heating capacity of radiant floor heating by 1 °C variation in floor temperature was calculated, and the remaining heating load was handled by the heating capacity of the convective air heating heat pump. Consequently, when the floor temperature was 25 °C, all heating loads were removed by radiant floor heating only. When handling all heating loads with the heat pump, 59.2% less energy was used compared with radiant floor heating only. Considering the local discomfort of the soles of the feet, the floor temperature is expected to be suitable at 22–23 °C, and 31.5–37.6% energy saving compared with those of radiant floor heating alone were confirmed.


Author(s):  
Zhang Guihong ◽  
Yang Yi ◽  
Chen Jianbo ◽  
Mei Tianxiang ◽  
Gu Haiqin ◽  
...  

2013 ◽  
Vol 805-806 ◽  
pp. 645-648
Author(s):  
Wei Xiu Shi ◽  
Li Sheng Pan

Under the situation of energy crisis, air source heat pumps are paid more attention recently. In order to save energy, the feasibility and performance of air source heat pump are studied by experiment, and variation laws of exhaust temperature, evaporator outlet temperature and outlet presser of compressor were analyzed in this paper. Air source heat pump apparatus were set up and the experiment was during 10°C, 20°C, 30°C and 40°C. The results were as follows: exhaust temperature of compressor increases gradually with the increase of tank temperature, but the temperature difference between exhaust temperature of compressor and tank temperature becomes little; temperature difference in evaporator decreases; Compressor outlet pressure increases obviously.