Failure analysis on circulating water pump of duplex stainless steel in 1000MW ultra-supercritical thermal power unit

2015 ◽  
Vol 47 ◽  
pp. 162-177 ◽  
Author(s):  
Yue-Yue Ma ◽  
Shi Yan ◽  
Zhen-Guo Yang ◽  
Guo-Shui Qi ◽  
Xin-You He
2018 ◽  
Vol 159 ◽  
pp. 02027 ◽  
Author(s):  
Abdul Hamid ◽  
Sri Nugroho ◽  
Gunawan Dwi Haryadi ◽  
Khaeroman

Pump shafts are generally exposed to the liquid being pumped either on a continual basis or at certain locations along the length of the shaft. The shaft material is austenitic stainless steel, description ASTM AU 79 TY 316. The purpose of this study is to determine the failure of the water pump shaft used in the power plant. Metallography is the study of structure metal shaft can used as a means for CWP metal pelleting (Circulating Water Pump), for the purpose of damaged or deeply degraded areas. SEM test is used to know the beginning of the crack (crack initiation). EDS test is used to chemical composition and Vikers hardness test is also used to know the hardness material. These three tests to support in analyzing the failure of the pump shaft. The conclusion of this failure analysis is the shaft material has porosity. Fatigue cracking comes from the outer surface area.


2014 ◽  
Vol 2 (2) ◽  
pp. 69-75 ◽  
Author(s):  
Jingqiang Yang ◽  
Qiongqi Wang ◽  
Zhongkun Wei ◽  
Kaishu Guan

2012 ◽  
Vol 591-593 ◽  
pp. 1094-1097
Author(s):  
De Qiang Wei ◽  
Xin Dong ◽  
Shan Qiu Li

As a kind of corrosion resistant material, stainless steel is widely used in petroleum, chemical, pharmaceutical. Stress corrosion cracking is a main reason that why the stainless steel became disabled. Therefore, it is very necessary to research and study the stress corrosion cracking of stainless steel .The failure analysis to the sample is conducted aiming at the stress corrosion of the stainless steel piston cylinder in a factory. The analysis includes macro analysis, metallographic observation, scanning electron microscopy analysis and XRD analysis. The results of the study show that it is nonmetallic inclusion on the grain boundary, the chloridion in the industrial circulating water and the rough columnar austenitic grains in the organization of the samples that lead to the stress corrosion cracking of the piston cylinder.


2020 ◽  
Vol 2020 (2) ◽  
pp. 1-9
Author(s):  
Mykola Bosak ◽  
◽  
Oleksandr Hvozdetskyi ◽  
Bohdan Pitsyshyn ◽  
Serhii Vdovychuk ◽  
...  

Analytical hydraulic researches of the circulating water cooling system of the power unit of a thermal power plant with Heller cooling tower have been performed. Analytical studies were performed on the basis of experimental data obtained during the start-up tests of the circulating water cooling system of the “Hrazdan-5” power unit with a capacity of 300 MW. Studies of the circulating water cooling system were carried out at an electric power of the power unit of 200 - 299 MW, with a thermal load of 320 - 396 Gcal/hr. By circulating pumps (CP), water mixed with condensate is fed to the cooling tower, from where it is returned through the turbine for spraying by nozzles in the turbine steam condenser. An attempt to increase the water supply to the condenser by increasing the size of the nozzles did not give the expected results. The amount of the water supply to the circulating pumping station depends on the pressure loss in the circulating water cooling system. The highest pressure losses are in hydro turbines (HT), which are part of the circulating pumping station. Therefore, by adjusting the load of the hydro turbine, with a decrease in water pressure losses, you can increase the water supply by circulating pumps to the condenser. Experimental data and theoretical dependences were used to calculate the changed hydraulic characteristics of the circulating water cooling system. As a result of reducing the pressure losses in the section of the hydro turbine from 1.04 to 0.15 kgf/cm2, the dictating point for the pressure of circulating pumping station will be the turbine steam condenser. The thermal power plant cooling tower is designed to service two power units. Activation of the peak cooler sectors of the cooling tower gives a reduction of the cooled water temperature by 2-4 °С only with the spraying system.


2013 ◽  
Vol 753-755 ◽  
pp. 2727-2730
Author(s):  
Jian Tao Liu ◽  
Xiao Cheng Ma ◽  
Kun Kun You ◽  
Jian Xing Ren ◽  
Yong Wen Yang

The thermal power unit is the major unit in Chinas power supply. Circulating water has large low-temperature waste-heat which can be recycled. The principles of water source heat pump technology is analyzed, characteristic of circulating water system in thermal power unit is studied. Then two kinds of connection methods between circulating water system and water source heat pump (WSHP) are presented.


2010 ◽  
Vol 17 (6) ◽  
pp. 1500-1506 ◽  
Author(s):  
S.S.M. Tavares ◽  
C. Scandian ◽  
J.M. Pardal ◽  
T.S. Luz ◽  
F.J. da Silva