Measurement of mass flow rate and evaluation of heat transfer coefficient for high-pressure pneumatic components during charge and discharge processes

2015 ◽  
Vol 45 ◽  
pp. 391-403 ◽  
Author(s):  
Longlong Gao ◽  
Gang Yang ◽  
Weijia Li ◽  
Baoren Li
2019 ◽  
Vol 16 (1) ◽  
pp. 33-44 ◽  
Author(s):  
M.K. Islam ◽  
Md. Hasanuzzaman ◽  
N.A. Rahim ◽  
A. Nahar

Sustainable power generation, energy security, and global warming are the big challenges to the world today. These issues may be addressed through the increased usage of renewable energy resources and concentrated solar energy can play a vital role in this regard. The performance of a parabolic-trough collector’s receiver is here investigated analytically and experimentally using water based and therminol-VP1based CuO, ZnO, Al2O3, TiO2, Cu, Al, and SiC nanofluids. The receiver size has been optimized by a simulation program written in MATLAB. Thus, numerical results have been validated by experimental outcomes under same conditions using the same nanofluids. Increased volumetric concentrations of nanoparticle is found to enhance heat transfer, with heat transfer coefficient the maximum in W-Cu and VP1-SiC, the minimum in W-TiO2 and VP1-ZnO at 0.8 kg/s flow rate. Changing the mass flow rate also affects heat transfer coefficient. It has been observed that heat transfer coefficient reaches its maximum of 23.30% with SiC-water and 23.51% with VP1-SiC when mass-flow rate is increased in laminar flow. Heat transfer enhancement drops during transitions of flow from laminar to turbulent. The maximum heat transfer enhancements of 9.49% and 10.14% were achieved with Cu-water and VP1-SiC nanofluids during turbulent flow. The heat transfer enhancements of nanofluids seem to remain constant when compared with base fluids during either laminar flow or turbulent flow.


2015 ◽  
Vol 62 (4) ◽  
pp. 509-522 ◽  
Author(s):  
R. Dharmalingam ◽  
K.K. Sivagnanaprabhu ◽  
J. Yogaraja ◽  
S. Gunasekaran ◽  
R. Mohan

Abstract Cooling is indispensable for maintaining the desired performance and reliability over a very huge variety of products like electronic devices, computer, automobiles, high power laser system etc. Apart from the heat load amplification and heat fluxes caused by many industrial products, cooling is one of the major technical challenges encountered by the industries like manufacturing sectors, transportation, microelectronics, etc. Normally water, ethylene glycol and oil are being used as the fluid to carry away the heat in these devices. The development of nanofluid generally shows a better heat transfer characteristics than the water. This research work summarizes the experimental study of the forced convective heat transfer and flow characteristics of a nanofluid consisting of water and 1% Al2O3 (volume concentration) nanoparticle flowing in a parallel flow, counter flow and shell and tube heat exchanger under laminar flow conditions. The Al2O3 nanoparticles of about 50 nm diameter are used in this work. Three different mass flow rates have been selected and the experiments have been conducted and their results are reported. This result portrays that the overall heat transfer coefficient and dimensionless Nusselt number of nanofluid is slightly higher than that of the base liquid at same mass flow rate at same inlet temperature. From the experimental result it is clear that the overall heat transfer coefficient of the nanofluid increases with an increase in the mass flow rate. It shows that whenever mass flow rate increases, the overall heat transfer coefficient along with Nusselt number eventually increases irrespective of flow direction. It was also found that during the increase in mass flow rate LMTD value ultimately decreases irrespective of flow direction. However, shell and tube heat exchanger provides better heat transfer characteristics than parallel and counter flow heat exchanger due to multi pass flow of nanofluid. The overall heat transfer coefficient, Nusselt number and logarithmic mean temperature difference of the water and Al2O3 /water nanofluid are also studied and the results are plotted graphically.


2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Xuan Jin ◽  
Chibing Shen ◽  
Xianyu Wu

The use of kerosene-based regenerative cooling for scramjet has been found widespread attention due to its inherent nature of high energy utilization efficiency and good thermal protection performance. In order to provide a reference for the later design and experiments, three-dimensional turbulence simulations and sensitivity analysis were performed to determine the effects of three operating mode parameters, heat flux, mass flow rate, and outlet pressure, on the regenerative cooling characteristics of kerosene scramjets. A single rectangular-shaped channel for regenerative cooling was assumed. The RNG k-ε turbulence model and kerosene cracking mechanism with single-step global reaction were applied for the supercritical-pressure heat transfer of kerosene flows in the channel. Conclusions can be drawn that as the kerosene temperature rises along the channel, the decrease of fluid density and viscosity contributes to increasing the fluid velocity and heat transfer. When the kerosene temperature is close to the pseudocritical temperature, the pyrolysis reaction results into the rapid increase of fluid velocity. However, the heat transfer deterioration occurs as the specific heat and thermal conductivity experience their turning points. The higher heat flux leads to lower heat transfer coefficient, and the latter stops rising when the wall temperature reaches the pseudocritical temperature. The same rising trend of the heat transfer coefficient is observed under different outlet pressures, but the heat transfer deterioration occurs earlier at smaller outlet pressure for the reason that the corresponding pseudocritical temperature decreases. The heat transfer coefficient increases significantly along with the rise of the mass flow rate, which is mainly attributable to the increase of Reynolds number. Quantitative results indicate that as the main influence factors, the heat flux and mass flow rate are respectively negatively and positively relative to the intensification of heat transfer, but outlet pressure always has little effects on cooling performance.


2013 ◽  
Vol 448-453 ◽  
pp. 3312-3315
Author(s):  
Bin Sun ◽  
Bin Bin Cui ◽  
Chao Liang

A three-dimensional physical mode of metal foam tube was built by CFD software. The Brinkman-Forchheimer extended Darcy equation and user-defined function (UFD) of the mass transfer and energy transfer between vapor phase and liquid phase compiled by C language were used in the simulation of boiling heat transfer in metal foam tube. The results show that, at a given mass flow rate, the pressure drop nonlinearly increases as the vapor quality rises; At the low mass flow rate, with the increasing of vapor quality, the flow pattern is transferred to wavy flow from stratified flow and then transfer to stratified wavy flow, while the heat transfer coefficient decreases with the increasing of vapor quality. At the high mass flow rate, with the increasing of vapor quality, the flow pattern is transferred to annular flow from slug flow, while the heat transfer coefficient increases with the increasing of vapor quality. The simulation results agree well with the experimental data.


Author(s):  
Kannan M. Munisamy ◽  
Hanan Mokhtar ◽  
Hasril Hasini ◽  
Mohd Zamri Yusof ◽  
Mohd Azree Idris

This paper presents the investigation on the effect of blade angle to the mass flow and heat transfer coefficient of a ventilated brake disc. Six different blade angle configurations are simulated using commercial computational fluid dynamics code, FLUENT. Important parameters such as mass flow rate of air through the ventilated blade and surface heat transfer coefficient are predicted and analyzed. Prediction shows reasonable estimation of mass flow rate and heat transfer coefficient on the disc brake. Linear trend is achieved on the mass flow and heat transfer coefficient as the vehicle speed increases. It is also concluded that the optimum mass flow and heat transfer coefficient are predicted at blade angle of 15°. The prediction provides an insight into the behavior of the air flow through the restricted passage of the brake disc design.


2019 ◽  
Vol 256 ◽  
pp. 03001
Author(s):  
Zhou Ying ◽  
He Chao ◽  
Bing Bai ◽  
Juan Ning

Extensive numerical study on the heat transfer performance of the gaseous nitrogen (GN) thermoregulation shroud surface was conducted in this work. The average heat transfer coefficient was investigated under different shroud length and nitrogen parameters (such as velocity, temperature and mass flow rate). The result shows that the heat transfer performance is affected less by shroud length but largely by mass flow rate. When the mass flow rate is constant, the inlet temperature increases heat transfer coefficient. Finally, dimensionless correlation of the average Nusselt number over shroud surface with Reynolds number and Prandtl number was obtained.


Nanomaterials ◽  
2019 ◽  
Vol 9 (9) ◽  
pp. 1231 ◽  
Author(s):  
Alfaryjat ◽  
Miron ◽  
Pop ◽  
Apostol ◽  
Stefanescu ◽  
...  

A modern computer generates a great amount of heat while working. In order to secure appropriate working conditions by extracting the heat, a specific mechanism should be used. This research paper presents the effect of nanofluids on the microchannel heat sink performance of computer cooling systems experimentally. CeO2, Al2O3 and ZrO2 nanoparticles suspended in 20% ethylene glycol and 80% distilled water are used as working fluids in the experiment. The concentration of the nanoparticles ranges from 0.5% to 2%, mass flow rate ranges from 0.028 kg/s to 0.084 kg/s, and the ambient temperature ranges from 25 °C to 40 °C. Regarding the thermal component, parameters such as thermophysical properties of the nanofluids and base fluids, central processing unit (CPU) temperature, heat transfer coefficient, pressure drop, and pumping power have been experimentally investigated. The results show that CeO2-EG/DW, at a concentration of 2% and a mass flow rate of 0.084 kg/s, has with 8% a lower temperature than the other nanofluids and with 29% a higher heat transfer coefficient compared with the base fluid. The Al2O3-EG/DW shows the lowest pressure drop and pumping power, while the CeO2-EG/DW and ZrO2-EG/DW show the highest. However, a slight increase of pumping power and pressure drop can be accepted, considering the high improvement that the nanofluid brings in computer cooling performance compared to the base fluid.


2013 ◽  
Vol 17 (5) ◽  
pp. 1443-1447
Author(s):  
Hui-Fan Zheng ◽  
Xiao-Wei Fan ◽  
Fang Wang ◽  
Yao-Hua Liang

A theoretical analysis and experimental verification on the characteristics of a micro-fin evaporator using R290 and R717 as refrigerants were carried out. The heat capacity and heat transfer coefficient of the micro-fin evaporator were investigated under different water mass flow rate, different refrigerant mass flow rate, and different inner tube diameter of micro-fin evaporator. The simulation results of the heat transfer coefficient are fairly in good agreement with the experimental data. The results show that heat capacity and the heat transfer coefficient of the micro-fin evaporator increase with increasing logarithmic mean temperature difference, the water mass flow rate and the refrigerant mass flow rate. Heat capacity of the micro-fin evaporator for diameter 9.52 mm is higher than that of diameter 7.00 mm with using R290 as refrigerant. Heat capacity of the micro-fin evaporator with using R717 as refrigerant is higher than that of R290 as refrigerant. The results of this study can provide useful guidelines for optimal design and operation of micro-fin evaporator in its present or future applications.


Author(s):  
Md. Habibur Rahman ◽  
Emdadul Haque Chowdhury ◽  
Didarul Ahasan Redwan ◽  
Hasib Ahmed Prince ◽  
M. Ruhul Amin

Abstract The current work aims to investigate the thermo-hydraulic performances of a dynamic wall heat exchanger by varying amplitude and frequency of the oscillating waveform. The lower wall of the channel is exposed to constant heat flux, the upper insulating wall is deforming in a sinusoidal waveform, and water is taken as the working fluid. The governing partial differential equations are solved by using the Arbitrary Lagrangian-Eulerian finite element method. The study has been performed in the transient regime for up to 1.0 second. At first the effects of frequency variation over the average mass flow rate, convective heat transfer coefficient, and the average liquid temperature have been observed for a particular amplitude of the dynamic wall. It has been found that the mass flow rate of water increases linearly with increasing frequency. Convective heat transfer coefficient decreases with increasing frequency up to 50 Hz, then starts to increase notably. Interestingly, the fluctuating average liquid temperature decreases and reaches a steady-state faster with increasing frequency. To explore the effect of amplitude over heat transfer characteristics, the amplitude ratio of the sinusoidal wave is varied maintaining a constant frequency of oscillation. It has been observed that with increasing amplitude, both mass flow rate and convective heat transfer coefficient increase exponentially. Increasing amplitude ratio from 0.5 to 0.9 results in an increment in the convective heat transfer coefficient by about 5 times. Although, the average liquid temperature decreases and reaches a steady state faster with increasing amplitude, initially the peak temperature of the water is recorded for the highest amplitude.


Sign in / Sign up

Export Citation Format

Share Document