scholarly journals On the operating speed and energy efficiency of GaN-based monolithic complementary logic circuits for integrated power conversion systems

Author(s):  
Zheyang Zheng ◽  
Han Xu ◽  
Li Zhang ◽  
Kevin J. Chen
Author(s):  
Michael J. Ellsworth ◽  
Gary F. Goth ◽  
Randy J. Zoodsma ◽  
Amilcar Arvelo ◽  
Levi A. Campbell ◽  
...  

Back in 2008 IBM reintroduced water cooling technology into its high performance computing platform, the Power 575 Supercomputing node/system. Water cooled cold plates were used to cool the processor modules which represented about half of the total system (rack) heat load. An air-to-liquid heat exchanger was also mounted in the rear door of the rack to remove a significant fraction of the other half of the rack heat load; the heat load to air. The next generation of this platform, the Power 775 Supercomputing node/system, is a monumental leap forward in computing performance and energy efficiency. The compute node and system were designed from the start with water cooling in mind. The result, a system with greater than 96% of it’s heat load conducted directly to water; a system that, together with a rear door heat exchanger, removes 100% of it’s heat load to water with no requirement for room air conditioning. In addition to the processor, memory, power conversion, and I/O electronics conduct their heat to water. Included within the framework of the system is a disk storage unit (disc enclosure) containing an interboard air-to-water heat exchanger. This paper will overview the water cooling system featuring the water conditioning unit and rack manifolds. Advances in technology over this system’s predecessor will be highlighted. An overview of the cooling assemblies within the server drawer (i.e. central electronics complex,) the disc enclosure, and the centralized (Bulk) power conversion system will also be given. Further, techniques to enhance performance and energy efficiency will also be described.


2012 ◽  
Vol 134 (2) ◽  
Author(s):  
Michael J. Ellsworth ◽  
Gary F. Goth ◽  
Randy J. Zoodsma ◽  
Amilcar Arvelo ◽  
Levi A. Campbell ◽  
...  

In 2008 IBM reintroduced water cooling technology into its high performance computing platform, the Power 575 Supercomputing node/system. Water cooled cold plates were used to cool the processor modules which represented about half of the total system (rack) heat load. An air-to-liquid heat exchanger was also mounted in the rear door of the rack to remove a significant fraction of the other half of the rack heat load: the heat load to air. The next generation of this platform, the Power 775 Supercomputing node/system, is a monumental leap forward in computing performance and energy efficiency. The computer node and system were designed from the start with water cooling in mind. The result, a system with greater than 96% of its heat load conducted directly to water, is a system that, together with a rear door heat exchanger, removes 100% of its heat load to water with no requirement for room air conditioning. In addition to the processor, the memory, power conversion, and I/O electronics conduct their heat to water. Included within the framework of the system is a disk storage unit (disc enclosure) containing an interboard air-to-water heat exchanger. This paper will give an overview of the water cooling system featuring the water conditioning unit and rack manifolds. Advances in technology over this system’s predecessor will be highlighted. An overview of the cooling assemblies within the server drawer (i.e., central electronics complex,) the disc enclosure, and the centralized (bulk) power conversion system will also be given. Furthermore, techniques to enhance performance and energy efficiency will also be described.


Integration ◽  
2011 ◽  
Vol 44 (1) ◽  
pp. 12-21 ◽  
Author(s):  
Mehrdad Khatir ◽  
Alireza Ejlali ◽  
Amir Moradi

Nanoscale ◽  
2019 ◽  
Vol 11 (45) ◽  
pp. 21824-21833 ◽  
Author(s):  
Jyoti V. Patil ◽  
Sawanta S. Mali ◽  
Chang Kook Hong

Controlling the grain size of the organic–inorganic perovskite thin films using thiourea additives now crossing 2 μm size with >20% power conversion efficiency.


2020 ◽  
Vol 8 (43) ◽  
pp. 15135-15141
Author(s):  
Jing Yan ◽  
Yuan-Qiu-Qiang Yi ◽  
Jianqi Zhang ◽  
Huanran Feng ◽  
Yanfeng Ma ◽  
...  

Two non-fullerene small molecule acceptors, NT-4F and NT-4Cl, were designed and synthesized. Power conversion efficiencies of 11.44% and 14.55% were achieved for NT-4Cl-based binary and ternary devices, respectively.


1993 ◽  
Vol 140 (6) ◽  
pp. 327-332
Author(s):  
M.-D. Shieh ◽  
C.-L. Wey ◽  
P.D. Fisher

Sign in / Sign up

Export Citation Format

Share Document