Two-step procedure for classifying consumers in a L-structured data context

2010 ◽  
Vol 21 (3) ◽  
pp. 270-277 ◽  
Author(s):  
Isabella Endrizzi ◽  
Flavia Gasperi ◽  
Daniela G. Calò ◽  
Evelyne Vigneau
Author(s):  
Mircea Fotino ◽  
D.C. Parks

In the last few years scanning tunneling microscopy (STM) has made it possible and easily accessible to visualize surfaces of conducting specimens at the atomic scale. Such performance allows the detailed characterization of surface morphology in an increasing spectrum of applications in a wide variety of fields. Because the basic imaging process in STM differs fundamentally from its equivalent in other well-established microscopies, good understanding of the imaging mechanism in STM enables one to grasp the correct information content in STM images. It thus appears appropriate to explore by STM the structure of amorphous carbon films because they are used in many applications, in particular in the investigation of delicate biological specimens that may be altered through the preparation procedures.All STM images in the present study were obtained with the commercial instrument Nanoscope II (Digital Instruments, Inc., Santa Barbara, California). Since the importance of the scanning tip for image optimization and artifact reduction cannot be sufficiently emphasized, as stressed by early analyses of STM image formation, great attention has been directed toward adopting the most satisfactory tip geometry. The tips used here consisted either of mechanically sheared Pt/Ir wire (90:10, 0.010" diameter) or of etched W wire (0.030" diameter). The latter were eventually preferred after a two-step procedure for etching in NaOH was found to produce routinely tips with one or more short whiskers that are essentially rigid, uniform and sharp (Fig. 1) . Under these circumstances, atomic-resolution images of cleaved highly-ordered pyro-lytic graphite (HOPG) were reproducibly and readily attained as a standard criterion for easily recognizable and satisfactory performance (Fig. 2).


1984 ◽  
Vol 15 (4) ◽  
pp. 267-274 ◽  
Author(s):  
Harriet B. Klein

Formal articulation test responses are often used by the busy clinician as a basis for planning intervention goals. This article describes a 6-step procedure for using efficiently the single-word responses elicited with an articulation test. This procedure involves the assessment of all consonants within a word rather than only test-target consonants. Responses are organized within a Model and Replica chart to yield information about an individual's (a) articulation ability, (b) frequency of target attainment, substitutions, and deletions, (c) variability in production, and (d) phonological processes. This procedure is recommended as a preliminary assessment measure. It is advised that more detailed analysis of continuous speech be undertaken in conjunction with early treatment sessions.


1994 ◽  
Vol 33 (05) ◽  
pp. 454-463 ◽  
Author(s):  
A. M. van Ginneken ◽  
J. van der Lei ◽  
J. H. van Bemmel ◽  
P. W. Moorman

Abstract:Clinical narratives in patient records are usually recorded in free text, limiting the use of this information for research, quality assessment, and decision support. This study focuses on the capture of clinical narratives in a structured format by supporting physicians with structured data entry (SDE). We analyzed and made explicit which requirements SDE should meet to be acceptable for the physician on the one hand, and generate unambiguous patient data on the other. Starting from these requirements, we found that in order to support SDE, the knowledge on which it is based needs to be made explicit: we refer to this knowledge as descriptional knowledge. We articulate the nature of this knowledge, and propose a model in which it can be formally represented. The model allows the construction of specific knowledge bases, each representing the knowledge needed to support SDE within a circumscribed domain. Data entry is made possible through a general entry program, of which the behavior is determined by a combination of user input and the content of the applicable domain knowledge base. We clarify how descriptional knowledge is represented, modeled, and used for data entry to achieve SDE, which meets the proposed requirements.


1992 ◽  
Vol 31 (04) ◽  
pp. 268-274 ◽  
Author(s):  
W. Gaus ◽  
J. G. Wechsler ◽  
P. Janowitz ◽  
J. Tudyka ◽  
W. Kratzer ◽  
...  

Abstract:A system using structured reporting of findings was developed for the preparation of medical reports and for clinical documentation purposes in upper abdominal sonography, and evaluated in the course of routine use. The evaluation focussed on the following parameters: completeness and correctness of the entered data, the proportion of free text, the validity and objectivity of the documentation, user acceptance, and time required. The completeness in the case of two clinically relevant parameters could be compared with an already existing database containing freely dictated reports. The results confirmed the hypothesis that, for the description of results of a technical examination, structured data reporting is a viable alternative to free-text dictation. For the application evaluated, there is even evidence of the superiority of a structured approach. The system can be put to use in related areas of application.


1996 ◽  
Vol 35 (03) ◽  
pp. 261-264 ◽  
Author(s):  
T. Schromm ◽  
T. Frankewitsch ◽  
M. Giehl ◽  
F. Keller ◽  
D. Zellner

Abstract:A pharmacokinetic database was constructed that is as free of errors as possible. Pharmacokinetic parameters were derived from the literature using a text-processing system and a database system. A random data sample from each system was compared with the original literature. The estimated error frequencies using statistical methods differed significantly between the two systems. The estimated error frequency in the text-processing system was 7.2%, that in the database system 2.7%. Compared with the original values in the literature, the estimated probability of error for identical pharmacokinetic parameters recorded in both systems is 2.4% and is not significantly different from the error frequency in the database. Parallel data entry with a text-processing system and a database system is, therefore, not significantly better than structured data entry for reducing the error frequency.


1981 ◽  
Vol 45 (02) ◽  
pp. 121-126 ◽  
Author(s):  
Utako Okamoto ◽  
Noboru Horie ◽  
Yoko Nagamatsu ◽  
Jun-Ichiro Yamamoto

SummaryMilk plasminogen-activator was partially purified from human transitional milk collected at about 10 days after delivery, by a five-step procedure involving chloroform treatment, ammonium sulfate precipitation, and column chromatography on Sephadex G-150, CM Sephadex C-50 and DEAE Sephadex A-50. This gave milk-activator with a maximum purification factor of about 2,400-fold with respect to the skimmed milk. The CM Sephadex-step preparation showed, on polyacrylamide gel electrophoresis, a single plasminogen-activator activity band located between the bands of albumin and prealbumin of human serum. This preparation exhibited no kinin forming activity. The activator hydrolyzed acetyl-glycyl-L-lysine methyl ester with similar order kinetic constants to urokinase, and was inhibited strongly by diisopropyl-fluorophosphate. The molecular weight of the activator as estimated by gel filtration was approximately 86,000, the isoelectric points as estimated by gel isoelectric focusing were pH 7.2, 6.9 and 6.6, and the activator activity was not quenched by antiurokinase globulin, indicating that the milk-activator is a different entity from urokinase.


2011 ◽  
Vol 14 (1) ◽  
pp. 67 ◽  
Author(s):  
Ireneusz Haponiuk ◽  
Maciej Chojnicki ◽  
Radosaw Jaworski ◽  
Jacek Juciski ◽  
Mariusz Steffek ◽  
...  

There are several strategies of surgical approach for the repair of multiple muscular ventricular septal defects (mVSDs), but none leads to a fully predictable, satisfactory therapeutic outcome in infants. We followed a concept of treating multiple mVSDs consisting of a hybrid approach based on intraoperative perventricular implantation of occluding devices. In this report, we describe a 2-step procedure consisting of a final hybrid approach for multiple mVSDs in the infant following initial coarctation repair with pulmonary artery banding in the newborn. At 7 months, sternotomy and debanding were performed, the right ventricle was punctured under transesophageal echocardiographic guidance, and the 8-mm device was implanted into the septal defect. Color Doppler echocardiography results showed complete closure of all VSDs by 11 months after surgery, probably via a mechanism of a localized inflammatory response reaction, ventricular septum growth, and implant endothelization.


Sign in / Sign up

Export Citation Format

Share Document