Direct Analysis in Real Time (DART) and a portable mass spectrometer for rapid identification of common and designer drugs on-site

2016 ◽  
Vol 1 ◽  
pp. 66-73 ◽  
Author(s):  
Hilary Brown ◽  
Berk Oktem ◽  
Ashley Windom ◽  
Vladimir Doroshenko ◽  
Kenyon Evans-Nguyen
The Analyst ◽  
2017 ◽  
Vol 142 (16) ◽  
pp. 2928-2935 ◽  
Author(s):  
Germán Augusto Gómez-Ríos ◽  
Tijana Vasiljevic ◽  
Emanuela Gionfriddo ◽  
Miao Yu ◽  
Janusz Pawliszyn

On-site analysis of complex matrices by SPME-TM coupled to a portable mass spectrometer via DART.


2019 ◽  
Vol 2019 ◽  
pp. 1-11 ◽  
Author(s):  
Fred P. M. Jjunju ◽  
Stamatios Giannoukos ◽  
Alan Marshall ◽  
Stephen Taylor

A portable mass spectrometer was coupled to a direct inlet membrane (DIM) probe and applied to the direct analysis of active fragrant compounds (3-methylbutyl acetate, 2-methyl-3-furanthiol, methyl butanoate, and ethyl methyl sulfide) in real time. These fragrant active compounds are commonly used in the formulation of flavours and fragrances. Results obtained show that the portable mass spectrometer with a direct membrane inlet can be used to detect traces of the active fragrant compounds in complex mixtures such as essential fragrant oils and this represents a novel in-situ analysis methodology. Limits of detection (LOD) in the sub-ppb range (< 2.5 pg) are demonstrated. Standard samples in the gaseous phase presented very good linearity with RSD % at 5 to 7 for the selected active fragrant compounds (i.e., isoamyl acetate, 2-methyl-3-furanthiol, methyl butanoate, and methyl ethyl sulphide). The rise and fall times of the DIM probe are in the ranges from 15 to 31 seconds and 23 to 41 seconds, respectively, for the standard model compounds analysed. The identities of the fragrance active compounds in essential oil samples (i.e., banana, tangerine, papaya, and blueberry muffin) were first identified by comparison with a standard fragrance compounds mixture using their major fragment peaks, the NIST standard reference library, and gas chromatography mass spectrometry (GC-MS) analysis. No sample preparation is required for analysis using a portable mass spectrometer coupled to a DIM probe, so the cycle time from ambient air sampling to the acquisition of the results is at least 65 seconds.


2015 ◽  
Vol 7 (17) ◽  
pp. 7156-7163 ◽  
Author(s):  
Adam E. O'Leary ◽  
Seth E. Hall ◽  
Kyle E. Vircks ◽  
Christopher C. Mulligan

In this paper, an ambient sampling, portable mass spectrometer coupled to a selection on ambient ionization methods was used to perform real-time reaction monitoring of clandestine methamphetamine syntheses.


2019 ◽  
Author(s):  
Anja Sundal ◽  
Ulrich Weber ◽  
Matthias Brennwald ◽  
Philip Ringrose ◽  
Nina Fl&oslash; ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document