Statistical uncertainty in the fatigue threshold staircase test method

2011 ◽  
Vol 33 (3) ◽  
pp. 354-362 ◽  
Author(s):  
Kim R.W. Wallin
2020 ◽  
Vol 10 (1) ◽  
pp. 394-400 ◽  
Author(s):  
I. M. W. Ekaputra ◽  
Rando Tungga Dewa ◽  
Gunawan Dwi Haryadi ◽  
Seon Jin Kim

AbstractThis paper presents the reliability estimation of fatigue strength of the material used for crank throw components. The material used for crank throw components is forged S34MnV steel and subsequently heat-treated by normalising and tempering. High cycle fatigue testing under fully reversed cycling (R = −1) was performed to determine the fatigue limit of the material. The staircase test method is used to obtain accurate values of the mean fatigue limit stress until a number of cycles up to 1E7 cycles. Subsequently, the fatigue test results depend strongly on the stress step and are evaluated by the Dixon-Mood formula. The values of mean fatigue strength and standard deviation predicted by the staircase method are 282 MPa and 10.6MPa, respectively. Finally, the reliability of the design fatigue strength in some selected probability of failure is calculated. Results indicate that the fatigue strength determined from accelerated staircase test is consistent with conventional fatigue testing. Furthermore, the proposed method can be applied for the determination of fatigue strength and standard deviation for design optimisation of S34MnV steel.


Author(s):  
M. A. Fedorova ◽  

During the operation of reciprocating compressors, the flapper valve opens and closes under fluid pressure and flow. As it closes, it strikes against the valve seat, generating stresses and noise. This cycle of loading produces bending and impact fatigue stresses in the reed. This load pattern is repeated billions of times during the service life of a compressor and it defines the service life and reliability. The goal of this study was to calculate the impact fatigue strength of the Flap-X and the SS 716 grades and, to provide the compressor manufacturers with the information they can use to specify a steel grade to be used in their compressors, for reliable service. Impact fatigue tests were conducted on a custom-built impact fatigue test rig that used air pulses to produce movement of the reed valves manufactured by a major European compressor manufacturer Nidec Global appliance GmbH, at a frequency of 315 Hz and pulse width of 2,2 milliseconds. The testing was conducted according to the staircase test method detailed in the International Standard SS-ISO 12107:2012. The impact fatigue strength of the Flap-X and SS 716 steel valves was calculated in terms of the impact velocity according to the modified staircase test method in the standard. The test results and their statistical analysis showed that the impact fatigue strength of the Flap-X grade was higher compared to the SS 716 grade. The calculation and testing of the impact fatigue strength of the flapper valve steel grades could help the compressor designers to select the optimum material for their compressor designs, to provide reliable service. The higher impact fatigue strength of the Flap-X grade, lower failure rate and longer impact fatigue life will allow the compressor manufacturers to design thinner valves, as Flap-X can sustain higher impact fatigue stresses reliably for longer time and, at the same time help reduce noise, as thinner valves produce less noise for a given pressure and frequency.


2019 ◽  
pp. 52-56
Author(s):  
Yu.F. Glukhov ◽  
N.V. Krutikov ◽  
A.V. Ivanov ◽  
N.P. Muravskaya

We have studied and analyzed status and metrological supervision of blood glucose monitors, individual devices for a person’s blood glucose level measurement. It has been indicated that nowadays blood glucose monitors like other individual devices for medical measurement are not allowed to be involved in telemedicine public service. This accounts for absence of metrological supervision with these measurement devices in telemedicine. In addition, the key problem is absence of safe methods and means of remote verificaition, calibration and transmission of measurement data to health care centers. The article offers a remote test method for blood glucose monitors using a number of resistors with values correlating with measured blood glucose level. The available method has been successfully trialed in real practice.


Author(s):  
Tran Minh Hieu ◽  
Nguyen Duong Ngoc Mai Chi

This study applied SERVQUAL scale of Parasuraman et al to measure factors affecting customer satisfaction on service quality at Vietnam Technological and Commercial Joint Stock Bank - An Giang Branch (Techcombank An Giang). The study was conducted to survey 207 customers who have been using the service at Techcombank An Giang. The survey results were analyzed by the Cronbach's Alpha reliability test method, then used Exploratory factor analysis (EFA) to verify and evaluate the scale of service quality. The results of the regression analysis show that customer's satisfaction about service quality at Techcombank An Giang includes four factors: The factor with the highest level is the Empathy with Beta = 0.253, the second of factor is the Responsibility with Beta = 0.248, ranked third in the influence level is the Tangible with Beta = 0.235, and the lowest impact level is the Reliability with Beta = 0.144. The research also uses statistical methods to describe and test the differences of demographic factors with customer's satisfactionon service quality.The analysis results show that there is no difference between customer's satisfaction on service quality and factors such as gender, age, income, number of transaction banks, regular transaction banks, and time to use the service at Techcombank An Giang. Through the research results, the author would like to propose some ideas to improve the quality of services, thereby attracting new customers and importantly, keeping traditional customers because the development orientation of Techcombank is to take care of old customers to cross sell other products of the bank. The Stud results offer a basis for the branch to identify the factors influencing customer satisfaction on their service quality, thereby having an appropriate strategy to improve customer satisfaction.


TAPPI Journal ◽  
2009 ◽  
Vol 8 (6) ◽  
pp. 24-28
Author(s):  
CORY JAY WILSON ◽  
BENJAMIN FRANK

TAPPI test T811 is the specified method to ascertain ECT relative to box manufacturer’s certification compliance of corrugated fiberboard under Rule 41/ Alternate Item 222. T811 test sample heights were derived from typical board constructions at the time of the test method’s initial development. New, smaller flute sizes have since been developed, and the use of lighter weight boards has become more common. The T811 test method includes sample specifications for typical A-flute, B-flute, and C-flute singlewall (and doublewall and triplewall) structures, but not for newer thinner E-flute or F-flute structures. This research explores the relationship of ECT sample height to measured compressive load, in an effort to determine valid E-flute and F-flute ECT sample heights for use with the T811 method. Through this process, it identifies challenges present in our use of current ECT test methods as a measure of intrinsic compressive strength for smaller flute structures. The data does not support the use of TAPPI T 811 for ECT measurement for E and F flute structures, and demonstrates inconsistencies with current height specifi-cations for some lightweight B flute.


Sign in / Sign up

Export Citation Format

Share Document