Heat transfer and pressure drop characteristics of peripheral-finned tube heat exchangers

2012 ◽  
Vol 55 (11-12) ◽  
pp. 2835-2843 ◽  
Author(s):  
Bruno F. Pussoli ◽  
Jader R. Barbosa ◽  
Luciana W. da Silva ◽  
Massoud Kaviany
Author(s):  
Maung Naing Naing Tun ◽  
Nilufer Egrican

This paper presents computer software developed for rating and optimum selection of finned circular tubes compact heat exchangers with various coil geometries. The software is developed to use as a computing tool for commercial and R&D purposes in FRITERM A.S, an original equipment manufacturer (OEM) of finned tube heat exchangers. Finned-tube heat exchangers are highly utilized in refrigeration and process industries and heat transfer and pressure drop calculations are very important to manufactures and design engineers. For this purpose, a simulation and design software to predict the performance of finned-tube heat exchangers is presented. In finned-tube coils fin side fluid is air and tube side fluid can be water, oil, glycol water solution mixture and refrigerants. The analysis and rating of coils at dry and wet operating conditions are presented. Design and the most suitable selections of coils at the given parameters and design constraints from many different coil geometries are also performed in the software. User-friendly object-oriented programming C# is applied in developing the software. The software is developed in modular basic. Six modules are developed: Heating Coils, Cooling Coils, Condenser Coils, Steam Coils, Heat Recovery Coils and Evaporator (DX) Coils. REFPROP is also integrated in the software and all fluids’ thermal and transport properties are obtained from REFPROP. Heat transfer and pressure drop correlations available from literature are evaluated with recommendations. Simulated results are verified against experimental results.


1999 ◽  
Vol 121 (4) ◽  
pp. 1018-1026 ◽  
Author(s):  
K. Hong ◽  
R. L. Webb

Limited previous work has shown that use of special hydrophilic coatings will provide lower air pressure drop in finned tube heat exchangers operated under dehumidifying conditions. However, no detailed work has been reported on the effect of different coating types, or different fin surface geometries on the wet pressure drop. In this study, wind tunnel tests were performed on three different fin geometries (wavy, lanced, and louver) under wet and dry conditions. All dehumidification tests were done for fully wet surface conditions. For each geometry, the tests were performed on uncoated and coated heat exchangers. For all three fin geometries, the wet-to-dry pressure drop ratio was 1.2 at 2.5 m/s frontal air velocity. The coatings have no influence on the wet or dry heat transfer coefficient. However, the wet surface heat transfer coefficient was 10 to 30 percent less than the dry heat transfer coefficient, depending on the particular fin geometry. The effect of the fin press oil on wet pressure drop was also studied. If the oil contains a surfactant, good temporary wetting can be obtained on an uncoated surface; however, this effect is quickly degraded as the oil is washed from the surface during wet operation. This work also provides a critical assessment of data reduction methods for wet surface operation, including calculation of the fin efficiency.


2009 ◽  
Vol 32 (5) ◽  
pp. 1032-1040 ◽  
Author(s):  
Hui Pu ◽  
Guo-liang Ding ◽  
Xiao-kui Ma ◽  
Hai-tao Hu ◽  
Yi-feng Gao

2018 ◽  
Vol 134 ◽  
pp. 277-291 ◽  
Author(s):  
Mohammad Sepehr ◽  
Seyed Saeed Hashemi ◽  
Mohammad Rahjoo ◽  
Vahid Farhangmehr ◽  
Ashkan Alimoradi

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2069
Author(s):  
Eloy Hontoria ◽  
Alejandro López-Belchí ◽  
Nolberto Munier ◽  
Francisco Vera-García

This paper proposes a methodology aiming at determining the most influent working variables and geometrical parameters over the pressure drop and heat transfer during the condensation process of several refrigerant gases using heat exchangers with pipes mini channels technology. A multi-criteria decision making (MCDM) methodology was used; this MCDM includes a mathematical method called SIMUS (Sequential Interactive Modelling for Urban Systems) that was applied to the results of 2543 tests obtained by using a designed refrigeration rig in which five different refrigerants (R32, R134a, R290, R410A and R1234yf) and two different tube geometries were tested. This methodology allows us to reduce the computational cost compared to the use of neural networks or other model development systems. This research shows six variables out of 39 that better define simultaneously the minimum pressure drop, as well as the maximum heat transfer, saturation pressure fluid entering the condenser being the most important one. Another aim of this research was to highlight a new methodology based on operation research for their application to improve the heat transfer energy efficiency and reduce the CO2 footprint derived of the use of heat exchangers with minichannels.


2006 ◽  
Vol 29 (7) ◽  
pp. 1138-1143 ◽  
Author(s):  
Branislav M. Jacimovic ◽  
Srbislav B. Genic ◽  
Boris R. Latinovic

Author(s):  
Ignacio Carvajal-Mariscal ◽  
Florencio Sanchez-Silva ◽  
Georgiy Polupan

In this work the heat transfer and pressure drop experimental results obtained in a two step finned tube bank with conical fins are presented. The tube bank had an equilateral triangle array composed of nine finned tubes with conical fins inclined 45 degrees in respect with the tube axis. The heat exchange external area of a single tube is approximately 0.07 m2. All necessary thermal parameters, inlet/outlet temperatures, mass flows, for the heat balance in the tube bank were determined for different air velocities, Re = 3400–18400, and one constant thermal charge provided by a hot water flow with a temperature of 80 °C. As a result, the correlations for the heat transfer and pressure drop calculation were obtained. The experimental results were compared against the analytical results for a tube bank with annular fins with the same heat exchange area. It was found that the proposed tube bank using finned tubes with conical fins shows an increment of heat transfer up to 58%.


2013 ◽  
Vol 832 ◽  
pp. 160-165 ◽  
Author(s):  
Mohammad Alam Khairul ◽  
Rahman Saidur ◽  
Altab Hossain ◽  
Mohammad Abdul Alim ◽  
Islam Mohammed Mahbubul

Helically coiled heat exchangers are globally used in various industrial applications for their high heat transfer performance and compact size. Nanofluids can provide excellent thermal performance of this type of heat exchangers. In the present study, the effect of different nanofluids on the heat transfer performance in a helically coiled heat exchanger is examined. Four different types of nanofluids CuO/water, Al2O3/water, SiO2/water, and ZnO/water with volume fractions 1 vol.% to 4 vol.% was used throughout this analysis and volume flow rate was remained constant at 3 LPM. Results show that the heat transfer coefficient is high for higher particle volume concentration of CuO/water, Al2O3/water and ZnO/water nanofluids, while the values of the friction factor and pressure drop significantly increase with the increase of nanoparticle volume concentration. On the contrary, low heat transfer coefficient was found in higher concentration of SiO2/water nanofluids. The highest enhancement of heat transfer coefficient and lowest friction factor occurred for CuO/water nanofluids among the four nanofluids. However, highest friction factor and lowest heat transfer coefficient were found for SiO2/water nanofluids. The results reveal that, CuO/water nanofluids indicate significant heat transfer performance for helically coiled heat exchanger systems though this nanofluids exhibits higher pressure drop.