Modelling punching shear failure at edge slab-column connections by means of nonlinear joint elements

Structures ◽  
2021 ◽  
Vol 34 ◽  
pp. 630-652
Author(s):  
Deema Abu-Salma ◽  
Robert L. Vollum ◽  
Lorenzo Macorini
2019 ◽  
Vol 197 ◽  
pp. 109372 ◽  
Author(s):  
Andri Setiawan ◽  
Robert L. Vollum ◽  
Lorenzo Macorini ◽  
Bassam Izzuddin

Author(s):  
Shinya Nakaue ◽  
Yasushi Nishimura

To improve the bearing failure behavior of the exterior steel beam-reinforced concrete column joints composed of reinforced concrete columns, joint details using steel column was proposed. Steel column was attached to the lower flanges at right angles to the steel flange. The objective of this study is to clarify the effectiveness of proposed joint details experimentally and theoretically. To clarify the influence of steel column on the bearing failure of the joint, seven T-shaped subassemblages were tested under reversed cyclic loading. All specimens had the same cross sections of the steel beam. The experimental variables were the embedded length of the steel column, whether there is the end plate at the tip of the embedded steel column, and, the arrangement of transverse reinforcement ratio surrounding the steel column. The following remarks can be drawn from the test results. 1) In case of the specimen with a short embedded length of the steel column, the punching shear failure on the upper surface of the steel beam flange was remarkable when the maximum strength was reached. However, in the specimen with long embedded length of steel column, it was not observed the punching shear failure. 2) The maximum strength increased with the embedded length of the steel column. Further, the maximum strength of the specimen with the embedded length of three times of the steel column depths is subjected to bending yield strength of the steel column. 3) It was shown that the transverse reinforcement to surround the steel column and the end plate were necessary to improve the bearing failure of the joint. 


Author(s):  
V. Kavinkumar ◽  
R. Elangovan

<div><p><em>This research is to study the mechanical properties of Self Compacting Concrete (SCC) as well as punching shear failure of SCC slabs. Self compacting concrete was first invited in 1988 to achieve durable concrete structures .Design of Reinforced concrete slab is often compromised by their ability to resist shear stress at punching shear surface area. The connection between slabs and supporting columns could be susceptible to high shear stress and might cause sudden and brittle failure. Punching shear failure takes the form of truncated pyramid shape. This program includes investigating the effect of SCC, slab thickness on the punching shear behaviour in terms of load-deflection response and ultimate failure load, failure characteristic of punching shear failure (shape of failure zone and size of failure zone) of simply supported slabs of 1000 x 1000 x 50 and 75mm under concentrated load at centre of slab. The slabs are made with both SCC and Conventional concrete (CC). Investigation included two way specimens with different thickness to evaluate the performance of specimen with different thickness and the effect of thickness on punching shear capacity and performance</em>.</p></div>


2015 ◽  
Vol 16 (3) ◽  
pp. 366-380 ◽  
Author(s):  
Beatrice Belletti ◽  
Mário Pimentel ◽  
Matteo Scolari ◽  
Joost C. Walraven

2005 ◽  
Vol 3 (2) ◽  
pp. 283-296 ◽  
Author(s):  
Ahmed Farghaly ◽  
Hitoshi Furuuchi ◽  
Tamon Ueda

2019 ◽  
Vol 972 ◽  
pp. 93-98
Author(s):  
Nurulain Hanida Mohamad Fodzi ◽  
M.H. Mohd Hisbany

This paper deals with behavior and capacity of punching shear resistance for ribbed slabs produce from self-compacting fiber reinforced concrete (SCFRC) by application of nonlinear finite element method. The analysis will be achieved by using ABAQUS software. The nonlinear finite element analysis by ABAQUS will be compare with the experimental results. Results and conclusions may be useful for establishing recommendation and need to be acknowledged.


2017 ◽  
Vol 738 ◽  
pp. 25-35
Author(s):  
Lukáš Lyčka ◽  
Petr Štěpánek

The use of flat slabs in constructions due to its many functional and economic advantages is wide-spread. Behavior of flat slabs in shear and flexure is a fairly complex problem. Therefore, the punching shear failure belongs to one of the most critical aspects in the design of concrete buildings.The purpose of this paper is to describe a framework of the proposed method for predicting the punching shear of flat slabs with shear reinforcement. Most of the current codes in force are mainly based on empirical formulation. The proposed method is based on a strut-and-tie model and therefore could be considered as an analytical approach. For the purpose of demonstrating the effectiveness of the proposed method, the method is compared with some of the main methods currently in use, such as Eurocode EC2, ACI 318 and Model Code 2010. The comparison consists of results of more than 90 experiments on flat slabs with shear reinforcement, gathered from publications from all around the world.


Sign in / Sign up

Export Citation Format

Share Document