scholarly journals In vitro compressive properties of skeletal muscles and inverse finite element analysis: Comparison of human versus animals

2020 ◽  
Vol 109 ◽  
pp. 109916
Author(s):  
Fuhao Mo ◽  
Zhefen Zheng ◽  
Haotian Zhang ◽  
Guibing Li ◽  
Zurong Yang ◽  
...  
2008 ◽  
Vol 295 (3) ◽  
pp. H1141-H1149 ◽  
Author(s):  
Gaurav Krishnamurthy ◽  
Daniel B. Ennis ◽  
Akinobu Itoh ◽  
Wolfgang Bothe ◽  
Julia C. Swanson ◽  
...  

We measured leaflet displacements and used inverse finite-element analysis to define, for the first time, the material properties of mitral valve (MV) leaflets in vivo. Sixteen miniature radiopaque markers were sewn to the MV annulus, 16 to the anterior MV leaflet, and 1 on each papillary muscle tip in 17 sheep. Four-dimensional coordinates were obtained from biplane videofluoroscopic marker images (60 frames/s) during three complete cardiac cycles. A finite-element model of the anterior MV leaflet was developed using marker coordinates at the end of isovolumic relaxation (IVR; when the pressure difference across the valve is ∼0), as the minimum stress reference state. Leaflet displacements were simulated during IVR using measured left ventricular and atrial pressures. The leaflet shear modulus ( Gcirc-rad) and elastic moduli in both the commisure-commisure ( Ecirc) and radial ( Erad) directions were obtained using the method of feasible directions to minimize the difference between simulated and measured displacements. Group mean (±SD) values (17 animals, 3 heartbeats each, i.e., 51 cardiac cycles) were as follows: Gcirc-rad= 121 ± 22 N/mm2, Ecirc= 43 ± 18 N/mm2, and Erad= 11 ± 3 N/mm2( Ecirc> Erad, P < 0.01). These values, much greater than those previously reported from in vitro studies, may result from activated neurally controlled contractile tissue within the leaflet that is inactive in excised tissues. This could have important implications, not only to our understanding of mitral valve physiology in the beating heart but for providing additional information to aid the development of more durable tissue-engineered bioprosthetic valves.


2019 ◽  
Vol 63 (3) ◽  
pp. 303-308 ◽  
Author(s):  
Toshiki Yamazaki ◽  
Natsuko Murakami ◽  
Shizuka Suzuki ◽  
Kazuyuki Handa ◽  
Masaru Yatabe ◽  
...  

2010 ◽  
Vol 28 (6) ◽  
pp. E11 ◽  
Author(s):  
Neil R. Crawford ◽  
Jeffery D. Arnett ◽  
Joshua A. Butters ◽  
Lisa A. Ferrara ◽  
Nikhil Kulkarni ◽  
...  

Different methods have been described by numerous investigators for experimentally assessing the kinematics of cervical artificial discs. However, in addition to understanding how artificial discs affect range of motion, it is also clinically relevant to understand how artificial discs affect segmental posture. The purpose of this paper is to describe novel considerations and methods for experimentally assessing cervical spine postural control in the laboratory. These methods, which include mechanical testing, cadaveric testing, and computer modeling studies, are applied in comparing postural biomechanics of a novel postural control arthroplasty (PCA) device versus standard ball-and-socket (BS) and ball-in-trough (BT) arthroplasty devices. The overall body of evidence from this group of tests supports the conclusion that the PCA device does control posture to a particular lordotic position, whereas BS and BT devices move freely through their ranges of motion.


Sign in / Sign up

Export Citation Format

Share Document