A simplified homogenization model applied to viscoelastic behavior of cortical bone at ultrasonic frequencies

2021 ◽  
pp. 110868
Author(s):  
Reidmen Aróstica ◽  
Ana Aguilera ◽  
Axel Osses ◽  
Jean-Gabriel Minonzio
2005 ◽  
Vol 128 (1) ◽  
pp. 13-17 ◽  
Author(s):  
T. L. Norman ◽  
E. S. Ackerman ◽  
T. S. Smith ◽  
T. A. Gruen ◽  
A. J. Yates ◽  
...  

Cementless total hip femoral components rely on press-fit for initial stability and bone healing and remodeling for secondary fixation. However, the determinants of satisfactory press-fit are not well understood. In previous studies, human cortical bone loaded circumferentially to simulate press-fit exhibited viscoelastic, or time dependent, behavior. The effect of bone viscoelastic behavior on the initial stability of press-fit stems is not known. Therefore, in the current study, push-out loads of cylindrical stems press-fit into reamed cadaver diaphyseal femoral specimens were measured immediately after assembly and 24h with stem-bone diametral interference and stem surface treatment as independent variables. It was hypothesized that stem-bone interference would result in a viscoelastic response of bone that would decrease push-out load thereby impairing initial press-fit stability. Results showed that push-out load significantly decreased over a 24h period due to bone viscoelasticity. It was also found that high and low push-out loads occurred at relatively small amounts of stem-bone interference, but a relationship between stem-bone interference and push-out load could not be determined due to variability among specimens. On the basis of this model, it was concluded that press-fit fixation can occur at relatively low levels of diametral interference and that stem-bone interference elicits viscoelastic response that reduces stem stability over time. From a clinical perspective, these results suggest that there could be large variations in initial press-fit fixation among patients.


2005 ◽  
Vol 128 (1) ◽  
pp. 7-12 ◽  
Author(s):  
T. R. Shultz ◽  
J. D. Blaha ◽  
T. A. Gruen ◽  
T. L. Norman

Many cementless implant designs rely upon a diaphyseal press-fit in conjunction with a porous coated implant surface to achieve primary or short term fixation, thereby constraining interface micromotion to such a level that bone ingrowth and consequent secondary or long-term fixation, i.e., osseointegration, can occur. Bone viscoelasticity, however, has been found to affect stem primary stability by reducing push-out load. In this investigation, an axisymmetric finite element model of a cylindrical stem and diaphyseal cortical bone section was created in order to parametrically evaluate the effect of bone viscoelasticity on stem push-out while controlling coefficient of friction (μ=0.15, 0.40, and 1.00) and stem-bone diametral interference (δ=0.01, 0.05, 0.10, and 0.50mm). Based on results from a previous study, it was hypothesized that stem-bone interference (i.e., press-fit) would elicit a bone viscoelastic response which would reduce the initial fixation of the stem as measured by push-out load. Results indicate that for all examined combinations of μ and δ, bone viscoelastic behavior reduced the push-out load by a range of 2.6–82.6% due to stress relaxation of the bone. It was found that the push-out load increased with μ for each value of δ, but minimal increases in the push-out load (2.9–4.9%) were observed as δ was increased beyond 0.10mm. Within the range of variables reported for this study, it was concluded that bone viscoelastic behavior, namely stress relaxation, has an asymptotic affect on stem contact pressure, which reduces stem push-out load. It was also found that higher levels of coefficient of friction are beneficial to primary fixation, and that an interference “threshold” exists beyond which no additional gains in push-out load are achieved.


2015 ◽  
Vol 801 ◽  
pp. 267-272 ◽  
Author(s):  
Alexandru Perescu ◽  
Oana Suciu ◽  
Adela Neamțu ◽  
Cristian Sorin Nes ◽  
Liviu Bereteu

The elastic properties of cortical bone tissue and other types of bone have been determined by the classical methods such as tensile stress and shearing stress. In recent years, by nanoindentation method, it has developed techniques for measuring the viscoelastic properties of bone tissues. In the same time, they show effects the dependent on time due to loading. The time dependent behavior of such viscoelastic materials may be described by constitutive equations whose variables are stress, deformation and time. These equations may be expressed by means of rheological models. Furthermore, bone tissues present both the phenomenon of creep and relaxation, indicating that they have a rheological behavior. In this paper viscoelastic behavior of bone is simulated numerically, and analyzed in Simulink, using Burgers rheological model.


2015 ◽  
Vol 15 (04) ◽  
pp. 1550050 ◽  
Author(s):  
H. MOTALLEBZADEH ◽  
M. TAFAZZOLI-SHADPOUR ◽  
M. M. KHANI

To determine the success of dental implants, mechanical stress distribution in the implant-bone interface is considered to be a determinant. Many researchers have used finite element modeling of implant-bone through applying static loading on the implant; however, dynamic loading has not extensively been investigated specially considering viscoelastic behavior of the bone. The aim of this study is to analyze effects of viscoelasticity of bone and dynamic loading comparable to mastication conditions on stress distribution in an implanted mandible. A three-dimensional finite-element model of an implanted mandible in the first molar region was constructed from computerized tomography data. Effects of several parameters, such as material properties including viscoelastic behavior of the cortical and trabecular bones, load amplitude, duration and direction on the instantaneous and long-term von Mises stress distribution of an implanted mandible were evaluated. In all loading conditions, the maximum von Mises stress occurred in cortical bone surrounding the neck of implant. Stress distribution was not noticeably affected by viscoelastic behavior during the first loading cycles, however, after 100 s periodic loading, the differences between stress magnitudes (especially in the cortical bone) became noticeable. In addition, sensitivity analysis showed that both cortical and trabecular bones were more sensitive to axial load than buccalingual and mesiodistal forces. The results of this study contribute to analysis of parameters involved in success of dental implantation.


2014 ◽  
Vol 20 (1) ◽  
pp. 41-49 ◽  
Author(s):  
Timothy J. Horn ◽  
Ola L.A. Harrysson ◽  
Harvey A. West II ◽  
Jeffrey P. Little ◽  
Denis J. Marcellin-Little

Purpose – The aim of this study is to describe an improved experimental substrate for the mechanical testing of patient-specific implants fabricated using direct metal additive manufacturing processes. This method reduces variability and sample size requirements and addresses the importance of geometry at the bone/implant interface. Design/methodology/approach – Short-fiber glass/resin materials for cortical bone and polyurethane foam materials for cancellous bone were evaluated using standard tensile coupons. A method for fabricating bone analogs with patient-specific geometries using rapid tooling is presented. Bone analogs of a canine radius were fabricated and compared to cadaveric specimens in several biomechanical tests as validation. Findings – The analog materials exhibit a tensile modulus that falls within the range of expected values for cortical and cancellous bone. The tensile properties of the cortical bone analog vary with fiber loading. The canine radius models exhibited similar mechanical properties to the cadaveric specimens with a reduced variability. Research limitations/implications – Additional replications involving different bone geometries, types of bone and/or implants are required for a full validation. Further, the materials used here are only intended to mimic the mechanical properties of bone on a macro scale within a relatively narrow range. These analog models have not been shown to address the complex microscopic or viscoelastic behavior of bone in the present study. Originality/value – Scientific data on the formulation and fabrication of bone analogs are absent from the literature. The literature also lacks an experimental platform that matches patient-specific implant/bone geometries at the bone implant interface.


1998 ◽  
Vol 11 (04) ◽  
pp. 200-204 ◽  
Author(s):  
K. Kelly ◽  
G. S. Martin ◽  
D. J. Burba ◽  
S. A. Sedrish ◽  
R. M. Moore

SummaryThe purpose of the study was to determine and to compare the in vitro pullout strength of 5.5 mm cortical versus 6.5 mm cancellous bone screws inserted in the diaphysis and metaphysis of foal third metacarpal (MCIII) bones in threaded 4.5 mm cortical bone screw insertion holes that were then overdrilled with a 4.5 mm drill bit. This information is relevant to the selection of a replacement screw if a 4.5 mm cortical screw is stripped during orthopaedic surgery. In vitro pullout tests were performed in two independent cadaver studies, each consisting of 12 foal MCIII bones. Two 4.5 mm cortical screws were placed either in the mid-diaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5 mm bit and had either a 5.5 mm cortical or a 6.5 mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/s until screw or bone failure occurred.The bone failed in all of the tests in the diaphyseal and metaphyseal bone. The holding power for 6.5 mm cancellous screws was significantly (p <0.05) greater than for 5.5 mm cortical screws in both the diaphysis and metaphysis. There was not any difference in the holding power of screws in either the diaphysis or the metaphysis between proximal and distal screw holes.If a 4.5 mm cortical bone screw strips in MCIII diaphyseal or metaphyseal bone of foals, a 6.5 mm cancellous screw would provide greater holding power than a 5.5 mm cortical screw.In order to provide information regarding selection of a replacement screw if a 4.5 mm cortical screw is stripped, the in vitro pullout strength was determined for 5.5 mm cortical and 6.5 mm cancellous screws inserted in third metacarpal diaphyseal and metaphyseal bone of foals in which threaded 4.5 mm cortical bone screw insertion holes had been overdrilled with a 4.5 mm bit. The holding power of the 6.5 mm cancellous screw was significantly greater than the 5.5 mm cortical screw in both the diaphysis and metaphysis of foal third metacarpal bone. Thus, it appears that if a 4.5 mm cortical screw is stripped during orthopaedic surgery in foals, a 6.5 mm cancellous screw would provide superior holding power.


2019 ◽  
Author(s):  
M Gado ◽  
M Noll ◽  
A Heinrich ◽  
M Rauner ◽  
LC Hofbauer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document