A novel rapid method for simultaneous determination of eight active compounds in silymarin using a reversed-phase UPLC-UV detector

2009 ◽  
Vol 877 (32) ◽  
pp. 4159-4163 ◽  
Author(s):  
Hong Liu ◽  
Zhenxia Du ◽  
Qipeng Yuan
2007 ◽  
Vol 90 (3) ◽  
pp. 693-699 ◽  
Author(s):  
Sonia Talaat Hassib ◽  
Mohammad Abdul-Azim Mohammad ◽  
Asmaa A El-Zaher ◽  
Ehab F El-Kady

Abstract New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere<sup/> 60 C18 column (250 4 mm, 5 m). The mobile phases, methanolwater (40:60, v/v) at 1 mL/min and methanol0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20240 and 560 g/mL for CH and KT, respectively, in the binary mixtures and 50300, 1060, and 20160 g/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.


2019 ◽  
Vol 15 (7) ◽  
pp. 694-702
Author(s):  
Sonia Talaat Hassib ◽  
Hanaa Abdelmenem Hashem ◽  
Marwa Ahmed Fouad ◽  
Nehal Essam Eldin Mohamed

Introduction: (COPD) Chronic Obstructive Pulmonary Disease is a partially reversible and treatable lung disease, characterized by progressive limitation of airflow. It is one of the main causes of mortality and morbidity worldwide. Methods: An easy, precise and selective reversed-phase liquid chromatographic method, with stabilityindicating assay was established and validated for the determination of indacaterol maleate and glycopyrronium bromide in the mixture. In addition, a forced degradation study was performed for indacaterol maleate, comprised of hydrolysis by acid and base, degradation by oxidation and heat, and photo-degradation. Separation and forced degradation were done by isocratic elution using a reversed phase phenyl column and (methanol: phosphate buffer) at ratio (65:35, v/v) with 3.5 pH buffer as an eluent at 1 mL min-1 as a flow rate. Quantitation was accomplished using a UV detector at 210 nm. Results: The method showed good separation of glycopyrronium bromide, indacaterol maleate and its degradation products. Accuracy, linearity, and precision were acceptable over 10-160 µg mL-1 and 10- 80 µg mL-1 concentration range for indacaterol maleate and glycopyrronium bromide, respectively. Conclusion: The proposed method does not require any previously done separation steps, making it applicable for the analysis of the drugs under investigation in their pharmaceutically marketed preparations.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3321
Author(s):  
Katarzyna Kurpet ◽  
Rafał Głowacki ◽  
Grażyna Chwatko

Biothiols are extremely powerful antioxidants that protect cells against the effects of oxidative stress. They are also considered relevant disease biomarkers, specifically risk factors for cardiovascular disease. In this paper, a new procedure for the simultaneous determination of human serum albumin and low-molecular-weight thiols in plasma is described. The method is based on the pre-column derivatization of analytes with a thiol-specific fluorescence labeling reagent, monobromobimane, followed by separation and quantification through reversed-phase high-performance liquid chromatography with fluorescence detection (excitation, 378 nm; emission, 492 nm). Prior to the derivatization step, the oxidized thiols are converted to their reduced forms by reductive cleavage with sodium borohydride. Linearity in the detector response for total thiols was observed in the following ranges: 1.76–30.0 mg mL−1 for human serum albumin, 0.29–5.0 nmol mL−1 for α-lipoic acid, 1.16–35 nmol mL−1 for glutathione, 9.83–450.0 nmol mL−1 for cysteine, 0.55–40.0 nmol mL−1 for homocysteine, 0.34–50.0 nmol mL−1 for N-acetyl-L-cysteine, and 1.45–45.0 nmol mL−1 for cysteinylglycine. Recovery values of 85.16–119.48% were recorded for all the analytes. The developed method is sensitive, repeatable, and linear within the expected ranges of total thiols. The devised procedure can be applied to plasma samples to monitor biochemical processes in various pathophysiological states.


Sign in / Sign up

Export Citation Format

Share Document