scholarly journals Simultaneous Determination of Chlorzoxazone and Ketoprofen in Binary Mixtures and in Ternary Mixtures Containing the Chlorzoxazone Degradation Product by Reversed-Phase Liquid Chromatography

2007 ◽  
Vol 90 (3) ◽  
pp. 693-699 ◽  
Author(s):  
Sonia Talaat Hassib ◽  
Mohammad Abdul-Azim Mohammad ◽  
Asmaa A El-Zaher ◽  
Ehab F El-Kady

Abstract New, simple, rapid, and precise reversed-phase high-performance liquid chromatographic (LC) methods were developed for the simultaneous determination of chlorzoxazone (CH) and ketoprofen (KT) in binary mixtures and in ternary mixtures containing the CH degradation product, 2-amino-4-chlorophenol (CD). The analytes were separated by LC on a Lichrosphere<sup/> 60 C18 column (250 4 mm, 5 m). The mobile phases, methanolwater (40:60, v/v) at 1 mL/min and methanol0.05% phosphoric acid (60:40, v/v, pH 2.81) at 1.5 mL/min, satisfactorily resolved the binary and ternary mixtures, respectively. The UV detector was operated at 280 nm for the determination of CH and at 254 nm for the determination of KT and CD. Linearity, accuracy, and precision were found to be acceptable over the concentration ranges of 20240 and 560 g/mL for CH and KT, respectively, in the binary mixtures and 50300, 1060, and 20160 g/mL for CH, KT, and CD, respectively, in the ternary mixtures. The optimized methods proved to be specific, robust, and accurate for the quality control of CH and KT in pharmaceutical preparations.

2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


2020 ◽  
Vol 11 (4) ◽  
pp. 8047-8053
Author(s):  
Potturi Ramadevi ◽  
Kantipudi Rambabu

The main objective of this research is to develop and validate a simple, specific, precise, sensitive, cost effective and rapid Reversed-Phase High-Performance Liquid Chromatographic (RP-HPLC) method for simultaneous quantification of Felodipine and Metoprolol in bulk and pharmaceutical dosage forms. The separation of the analytes were carried out on a X-bridge phenyl column with a moving phase composed of 0.1 % Tri ethyl amine: acetonitrile (30:70 v/v) delivered at a stream of 1.0 ml/min, and separation has been observed by UV detector, at a detection wavelength of 235 nm. This method was proven to be linear over a concentration limit of 10-150 µg/ml for Metoprolol, 2-30 µg/ml for Felodipine with correlation coefficient of 0.999. The retention time of Metoprolol and Felodipine were 2.936, 4.535 minutes respectively. To separate Metoprolol and Felodipine peaks a run time of 8 min. was used. The validation results were in good agreement with acceptable limits. RSD values which are less than 2.0 % indicating the accuracy and precision of this method. Hence it was evident that the proposed method was said to be a suitable one for the regular analysis and quality control of pharmaceutical preparations which contain these active drugs either individually or in combination.


2009 ◽  
Vol 92 (2) ◽  
pp. 404-409 ◽  
Author(s):  
Abdalla A Elshanawane ◽  
Samia M Mostafa ◽  
Mohamed S Elgawish

Abstract A high-performance liquid chromatographic method was developed for the simultaneous determination of 2 ternary mixtures containing amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone used in hypertension therapy. The use of cyanopropyl column results in satisfactory separation of both mixtures. The mobile phase consisted of 10 mM KH2PO4 buffer (pH 4.5) and methanol in a ratio of (75 25 v/v), at a flow rate of 1 mL/min. UV detector was operated at 275 nm. Calibration graphs were linear in the concentration ranges of 210, 20200, 10100, and 550 g/mL for amiloride hydrochloride, atenolol, hydrochlorothiazide, and chlorthalidone, respectively. Intraday and interday precision values (relative standard deviation) were <1.13 for mixture I (amiloride hydrochloride, atenolol, chlorthalidone), and <0.93 for mixture II (amiloride hydrochloride, atenolol, hydrochlorothiazide). The method was successfully applied for the determination of the 2 combinations in laboratory-prepared mixtures and commercial pharmaceutical formulation with high accuracy and precision. Statistical comparison of the results with those of the published methods showed excellent agreement and indicates no significant difference between them.


1993 ◽  
Vol 39 (11) ◽  
pp. 2229-2234 ◽  
Author(s):  
Z Zaman ◽  
P Fielden ◽  
P G Frost

Abstract A reversed-phase high-performance liquid-chromatographic method for the simultaneous determination of retinol, alpha-tocopherol, alpha-carotene, beta-carotene, cryptoxanthin, lutein/zeaxanthin, and lycopene is described. This method was applied to plasma measurements in healthy young and elderly subjects. The plasma, deproteinized with ethanol, is extracted twice with n-hexane. After evaporation, the residue is dissolved in 50 microL of tetrahydrofuran and made up to 200 microL with ethanol. Samples (50 microL) are injected onto a 250 x 4.6 mm column of 5-microns-particle Spherisorb ODS1 (Phase Separations) that had been equilibrated with solvent mixture A:B (90:10 by vol) [A = 100 mmol/L ammonium acetate in methanol: acetonitrile (80:20 by vol) and B = 100 mmol/L ammonium acetate in water] at 2 mL/min. The analytes are eluted by running a 12-min linear gradient to 100% A; solvent A is then maintained for 10 min. Intrabatch CVs were 2.3%, 3.3%, 2.8%, 3.6%, 3.6%, and 3.0% for retinol, alpha-tocopherol, lutein/zeaxanthin, cryptoxanthin, lycopene, and beta-carotene, respectively. The corresponding interbatch CVs were 4.9%, 5.8%, 12.3%, 6.5%, 8.0%, and 3.4%.


2012 ◽  
Vol 554-556 ◽  
pp. 2037-2040
Author(s):  
Yu Qin Li ◽  
Jing Zhao ◽  
Rui Duan ◽  
Bao Xiu Jia ◽  
Gui Rong You ◽  
...  

A reversed-phase high performance liquid chromatographic method was established for the simultaneous determination of tanshinones in three processing products of white flower Radix salvia miltiorrhiza. Cryptotanshinone, tanshinone IA and tanshinone IIA were successfully separated on a Yilite C18 column (250 mm x 4.6 mm, 5 µm). The mobile phase was a mixture of methanol, water, tetrahydrofuran and glacial acetic acid (70:24:5:1, v/v/v/v), employing isocratic elution at a flow rate of 1.0 mL/min. Detection was 254 nm. Regression equations revealed good linear relationship between the peak areas of the compounds and their concentrations (correlation coefficients: 0.9994 for cryptotanshinone, 0.9996 for tanshinone I A and 0.9996 for tanshinone IIA). The recoveries were between 98.03 % and 103.1 %. The method is simple, accurate and effective and can be used to determine the contents of tanshinones in processing products of Salvia miltiorrhiza bge. f. alba, and the contents of three tanshinones presented the stir-frying processing<the crude drugs<the wine prosessing.


Author(s):  
Hemraj Sharma ◽  
Boya Madhuri ◽  
Yiragamreddy Padmanabha Reddy ◽  
Kondareddy Vinod Kumar ◽  
Nanda Kishor Bhatta ◽  
...  

A novel approach was used to develop and validate a rapid, specific, accurate and precise Reverse phase High performance liquid chromatographic (RP-HPLC) method for the simultaneous determination of Metformin and Sitagliptin in pharmaceutical dosage forms and its applications to dissolution study. The chromatographic separation was carried out on a C8 (250mm X 4.6 mm i.d., 5μm) column with a mobile phase of 40 Acetonitrile: 60 Phosphate Buffer (pH 6.8), using UV detector at 257 nm at 1ml min-1 flow rate. The retention time for Metformin was 2.11 minutes and 5.30 minutes for Sitagliptin. The Linearity for Metformin was found to be 10-80 µg ml-1 with R2 value of 0.9998 and for Sitagliptin 1-8 µg ml-1 with R2 value of 0.9976. Dissolution study of both for Metformin and Sitagliptin was carried, Percentage of drug release was established which was found to be 96.23% and 102.64% respectively, in the period of 50 minutes. Keywords: RP-HPLC, Metformin, Sitagliptin, Dissolution study


1988 ◽  
Vol 34 (4) ◽  
pp. 724-729 ◽  
Author(s):  
M Hariharan ◽  
T VanNoord ◽  
J F Greden

Abstract We describe a rapid, sensitive method for the routine simultaneous determination of nicotine and cotinine in 1 mL of plasma. Extraction in 10-mL screw-capped Teflon tubes with methylene chloride after deproteinization with trichloroacetic acid eliminated emulsion formation. The extract, after evaporation and reconstitution in 30 microL of mobile phase, is injected into a reversed-phase C-18 ion-pair column of an isocratic high-performance liquid-chromatographic unit. Absorbance is monitored at 256 nm. The mobile phase is a citrate-phosphate (30 mmol each per liter) buffer mixture containing 50 mL of acetonitrile and 1 mmol of sodium heptanesulfonate per liter. 2-Phenylimidazole is the internal standard. The detection limit is 1 microgram/L for nicotine and 3 micrograms/L for cotinine. The standard curve is linear from 0 to 700 micrograms/L for both compounds. The average CV for nicotine in the concentration range 0-100 micrograms/L is 6.5%, and that for cotinine in the concentration range 50-700 micrograms/L is 4%.


2010 ◽  
Vol 7 (1) ◽  
pp. 198-202 ◽  
Author(s):  
R. Shinde Sachin ◽  
I. Bhoir Suvarna ◽  
S. Pawar Namdev ◽  
B.Yadav Suman ◽  
M. Bhagwat Ashok

A Simple, fast and precise reversed phase high performance liquid chromatographic method is developed for the simultaneous determination of satranidazole and ofloxacin. Chromatographic separation of these drugs were performed on Kromasil C18column (250 x 4.6 mm, 5 µ) as stationary phase with a mobile phase comprising of 20 mM potassium dihydrogen phosphate: acetonitrile in the ratio of 60:40 (v/v) containing 0.1% glacial acetic acid at a flow rate of 1 mL/min and UV detection at 318 nm. The linearity of satranidazole and ofloxacin were in the range of 1.5 to 3.6 µg/mL and 1.0 to 2.4 µg/mL respectively. The recovery was calculated by standard addition method. The average recovery was found to be 100.63% and 100.02% for satranidazole and ofloxacin respectively. The proposed method was found to be accurate, precise and rapid for simultaneous determination of satranidazole and ofloxacin